Think Smart Work Better

Slides:



Advertisements
Similar presentations
Process Management System Economical Automation with Standard Software
Advertisements

NIR Sensor Technology-Spectroscopy
Leaders in Light Perfect for Raman. Agenda Short corporate profile Advantages of the Starbright technology Our demanding quality assurance programme Overview.
NexSentry Imaging Solutions
Catalyst Chemical Injection Systems. Catalyst System Family.
1 The YL9100S HPLC All your needs for semi-preparative applications.
D e t e c t o r s f o r H P L C.
Good Practices of Fluorescence Spectroscopy
Teledyne Analytical Instruments
NEXGEN Four All automated microplate processors today can perform the steps required to process an ELISA microplate test However, most systems today operate.
Teledyne Isco Confidential
Cruces-Blanco, C., Gamiz-Gracia, L., Garcia-Campana A.M., Applications of Capillary Electrophoresis in Forensic Analytical Chemistry Trends in Analytical.
Compact & Perfect for Your Satisfaction
Microspectrophotometry Validation. Reasons for Changing Instruments Reduced reliability. Limited efficiency. Limited availability and cost of replacement.
Statistical Process Control for the Medical Industry.
UV-vis. Applications Quantitative analysis Organics (if composition is simple and known) Specific binding to chromaphore Metal-ligand absorption (d-orbital.
Introducing the EASY-nLC™
Advanced Spectroscopy 2. UV-VIS Spectroscopy. Revision 1.What are the wavelength ranges for the ultraviolet and visible regions of the spectrum?  UV:
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
MINIATURE MODULAR SAMPLE SYSTEMS – FROM CONCEPT TO REALITY David M. Simko, Swagelok Company Pittcon®2002 New Orleans, March 20, 2002.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
Introducing the LEO 1400 Series
Waters Corporation Connecting Data to Decisions John Swallow Principal Engineer Waters Data Products
EZPump tm SSI Pump Control for EZChrom SI tm And EZChrom Elite tm.
ProStar 325 Detector Petro van Poppel – Field Support Specialist Friday, 9 October 2015.
Varian 920-LC Integrated Analytical HPLC
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Introducing the Varian 356-LC Refractive Index Detector
900-LC P. van Poppel – Field Support Specialist October 2009.
Varian 900-LC Series iHPLC
VARIAN, INC. HPLC Products
HPLC Instrument Manager, Europe Region 1
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Analysis of Ibuprofen in Tablets According to the US Pharmacopoiea using a Varian 920-LC Analytical HPLC and Pursuit ® XRs column By Phuong Truong Varian.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Simple Double Beam Spectrometer
Sales Objections and FAQ’s 940-LC Analytical to Preparative Systems.
Comparison of Competitor
HPLC Installation Petro van Poppel – Field Support SpecialistMarch 2010.
Sales Objections and FAQs 920-LC Analytical Systems.
The 900 series LC Analytical 920 LCSemi-Prep 940 LC.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Varian Integrated HPLC Systems (iHPLC) Frankie Button HPLC Instrument Manager, Europe Region 1 November 2007.
HPLC detectors Adapted from: HPLC for Pharmaceutical Scientists
Diagnostics – Detectors Analytical 920 LCSemi-Prep 940 LC.
VALIDATIONS: TOWARDS RELAIBLE QUALITY OUTCOMES DR. SHIVPRAKASH MANAGING DIRECTOR SYNCHRON RESEARCH SERVICES PVT. LTD., INDIA.
SSI Binary Gradient Pump Modular Simplicity. Ideal Gradient Characteristics Modular design Small foot print Easy Maintenance Compatible with stand alone.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Introduction to training
Spectrophotometer.
212-LC Pump Technology Background August Dual Piston Pump Single piston pumps deliver then refill, forcing the use of a very large pulse damper.
ProStar 335 Detector Wednesday, 26 April 2017
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
RECENT DEVELOPMENT IN SUM FREQUENCY GENERATION SPECTROSCOPY SYSTEMS
I & C.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
AIQ Analytical Instrument Qualification. AIQ – Analytical Instrument Qualification Varian, Inc.’s Analytical Instrument Qualification documentation has.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Sensistor ISh2000 Hydrogen Leak detector
Simple Double Beam Spectrometer
LIQUID CHROMATOGRAPHY
Varian 940-LC Analytical to Prep HPLC
FlexarTM: Advances in HPLC Sample Throughput
Agilent 1100 Series System Operating principles
Direct digital control systems &Software
Diagnostics Analytical 920 LC Semi-Prep 940 LC
High Accuracy UV-VIS Spectroradiometer ( nm)
OL 750 Measurement Systems
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Presentation transcript:

Think Smart Work Better The New YL9100 HPLC Think Smart Work Better

The History of HPLC development 1989 1997 2000 2008 CE CE Acme 9000 YL9100 Analog Integrator Manual Analog Software Manual Digital Software-control Autosampler Network HPLC Reliable Design Powerful CDS Fully automated PDA available

YL9100 HPLC Overview What is the innovated from Acme 9000 HPLC Superior Performance Greater Reliability Excellent Usability Serviceability and Easy Maintenance Higher Cost-Effectiveness

YL9100 HPLC – Features 1 Superior Performance Network (LAN) communication - High speed data transfer and real time processing Higher performance solvent delivery pump - New designed carrier assembly and CAM - Improvement of precision of flow rate Better UV/Vis detector with new optic design - Seya-Namioka, New Blazed Holographic concave grating New Detector – Photo Diode Array with excellent sensitivity

YL9100 HPLC – Features 2 Greater Reliability Improvement of System components - New designed main parts of Pump, Detectors and Column compartment with very robust materials Innovative manufacturing process - Three step quality control and assurance system

YL9100 HPLC – Features 3 Excellent Usability Intuitive, intelligent and powerful software - Easy control window for instruments - Harmonization Microsoft’s standards for accessing flies, reviewing data and reports, and other tasks - System Suitability Test with USP, EP and JP - Compliance with 21 CFR Part 11 - Diagnostics and Error detection Automation Perfectly of Analysis work - Startup, analysis operation, shut down, … , and to report generation

Serviceability and Easy Maintenance YL9100 HPLC – Features 4 Serviceability and Easy Maintenance Better long-life components - New designed the carrier, CAM, needle bearing, seals and belt (with polyurethane) for long-life time - New designed the Deuterium and Tungsten lamp guaranteed 2,000 hours - Semi-permanent peltier in the Column Compartment Easy Maintenance - Easy replacement and pre-alignment of lamps - Easy replacement of sample cell assembly - Diagnostics procedure by software

Higher Cost-effectiveness YL9100 HPLC – Features 4 Higher Cost-effectiveness Cost between YL and “A” Configuration YL9100 HPLC “A” company Isocratic System 15,400$ 16,000$ Full QLPG 33,700$ 33,000$ Better performance between YL and “A” UV Detector YL9100 HPLC “A” company Wavelength range 190-900 nm 190-600nm Baseline Noise ± 0.5 x 10-5 AU at 254 nm ± 0.75 x 10-5 AU at 254 nm Baseline Drift <1 x 10-4 AU at 254 nm 3 x 10-4 AU/hr at 254 nm Data acquisition rate Max 50 Hz Max 13Hz Plus Two Years Warranty…….

YL9100 HPLC – Modules What is the innovated from each module Vacuum Degasser Pump Column Compartment UV/Vis Detector PDA Detector *New

YL9100 HPLC – Modules -VD YL9101 Vacuum Degasser - No fluctuation, shorten warming up Number of channel : 4 CHs Maximum degassing range: 10ml/min High capacity of chamber: 925ul per channel Excellent compatibility with Toxic chemicals : degassing membrane with Teflon® AF Robust ZHCR® vacuum pump – 220 million cycle Safety & maintenance : Vacuum Error detection Wide range of Line Voltage : 100-240VAC, ±10%, Wide range Line frequency : 50/60Hz, ±5% Power consumption : 20W

YL9100 HPLC – Modules – QP/BP/IP YL9110 Quaternary Pump YL9111 Binary Pump YL9112 Isocratic Pump New design of mechanical parts of pumps Compressibility Compensation technology Semi-automatic Prime/Purge Built-in Leak sensor Wide flow range by each check valve with two balls Ultra robust carrier, bearing, belt, etc A new Binary Pump in a module

YL9100 HPLC – Modules – BP YL9111 Binary Pump A New Pump for higher throughput and reproducibility The best pump for High Pressure Gradient System Built-in Large capacity static mixer X2 Parallel dual-plunger Attractive price compared to QP

YL9100 HPLC – Modules – QP/IP YL9110 Quaternary Pump Attached 4-way mixing valve to QP YL9112 Isocratic Pump Improved Isocratic Pump with parallel dual-plunger Easy upgraded from IP to QP

YL9100 HPLC – Modules -CC YL9130 Column Compartment - Powerful temperature control The best temperature precision: ±0.05°C Powerful Cooling is the standard: down to 4 °C Preheating available Semi-automatic injector/Switching valve: up to 1 (option: max. 2) Column capacity: 300mm – 4ea Leak sensor 40 steps programming

YL9100 HPLC – Modules -UVD YL9120 UV/Vis Detector - Excellent sensitivity New designed Optic structure: Seya-Namioka New Blazed Holographic Concave Grating Excellent Data acquisition rate: up to 50 Hz Long-life D2 lamp Advanced band width: 5.5 nm Excellent Sensitivity: <±0.5 x 10-5 AU at 254nm Integrated cell and slit assembly Greater cooling of the lamp’s thermal environment Tested flow cell guarantee up to 1,500 psi(103 bar) Optimal cell volume and path length for analytical method development and QC/QA Leak sensor

YL9100 HPLC – Modules -UVD YL9120 UV/Vis Detector What is the Seya-Namioka monochromator - To attach New Blazed Holographic Concave Grating - Extremely low stray light - Highest light intensity - Reduced astigmatism - Very compact design and size - More serviceability - High performance beam splitter - New designed an integrated cell+slit assembly - Excellent band width, 5.5nm

YL9100 HPLC – Modules -PDA YL9160 PDA Detector - Highest Sensitivity Optimum wavelength resolution: 1,024 diodes Wide range from 190 to 950 nm Highest Sensitivity <±1.0 x 10-5 AU at 254nm, 2 sec rise time <±2.0 x 10-5 AU at 254nm, 1 sec rise time Fast data acquisition: 50 Hz Greatest drift level <2.0 x 10-4 AU/h at 254nm, Baseline correction <1.0 x 10-3 AU/h at 254nm

YL9100 HPLC – Modules -RID YL9170 RID - For universal detection, GPC and sugar analysis RI Range : 1.00 ~ 1.75 RIU Noise : < ±1.3 x 10-8 RIU Linear dynamic range : 80 x 10 -5 RIU Drift range : 0.8 x 10 -7 RIU/h Flow rate range : 0.2 ~ 3.0 ml/min(analytical) Narrow-bore & Semi-prep also available Cell pressure : 6 kg/cm2(84 psi)

YL9100 HPLC – Modules -ELSD YL9180 ELSD / YL9181 ELSD - For universal detection, Better sensitive than RID Universal detector to analyze components which do not have UV absorption, cannot be separated with an isocratic solvent and must use a gradient elution, which cannot be used with a refractive index detector. Only mobile phases without any buffers should be used Display: 2 line x 20 character per line VFDL Operating Conditions: Intended for indoors operation only. 60°F to 85°F and <90% R.H. non condensing Evaporative Zone Temperature: Ambient to 120°C Nebulization Chamber Temperature: Ambient to 60°C(10-70 °C for 9181) Gas Requirement: 65psi ± 5 psi Nitrogen or other inert gas Gas Consumption: Approximately 2.5 SLPM Liquid Flow Rate: 0.25 ml/min. to 3 ml/min (0.2mL/min to 5mL/min for 9181) Electrical Requirement: 120 V AC, 50/60 Hz or 240 V AC, 50/60 Hz 600 Watts Wetted Materials: Stainless Steel, glass, Anodized Aluminum, Teflon Light Source: 670 nM Laser Diode, <5 m W Detector: Hermetically Sealed Photo-Diode/Operational Amplifier Output Signal: 0-5 VDC, Communications: RS-232

YL9100 HPLC – Modules -AS YL9150 Autosampler - Fully automated work Sample capacity :96 standard vials Option: 384 vials, 24 vials(10ml for prep) Sample loop: 100ul(standard) Injection cycle time: <60 sec Injection: full loop, partial loop and ul pickup RSD <=0,3% at full loop <=0.5% at partial loopfill inj. <=1.0% at uL pickup inj. Carry-over < 0.05% Option: Built-in Peltier cooling (4oC ~ ambient –3oC)

YL9100 HPLC – Modules -CDS YL-Clarity CDS 1 2 Measuring Post-run - Intelligent and Powerful Chromatography Data Station 2 Post-run Automatically displays, prints, exports and starts other programs 1 Measuring Four Instruments up to 12 detectors.

YL9100 HPLC – Modules -CDS 3 5 4 6 7 8 Column performance Audit trail Method validation By USP, EP and JP 5 Audit trail Records selected events and operations into a special file. 4 User accounts Sets up access rights and passwords 6 Electronic signature Each chromatogram can be signed electronically. 7 Networked Solution Clarity files can be accessed from networked computers using Clarity Offline software. 8 Great Compatibility Window XP/2000. Window Me/98, and Window Vista (32bit) is available

YL9100 HPLC – Modules -CDS YL-Clarity CDS Perfectly compliance with 21CFR Part 11 GPC option available System Suitability Test option available(Method validation) PDA module option available: 3-D data analysis Software Validation option available: Software OQ

YL9100 HPLC – Competition vs A Specifications of YL9100 VS “A” company low cost model YL9100 “A” 1120 Degassing 4-channel 2-channel Pumps Isocratic/QLPG/BHPG Isocratic/QLPG UV/Vis Detector Wavelength range 190-900 nm 190-600nm Baseline Noise ± 0.5 x 10-5 AU at 254 nm ± 0.75 x 10-5 AU at 254 nm Baseline Drift <1 x 10-4 AU at 254 nm 3 x 10-4 AU/hr at 254 nm Data acquisition rate Max 50 Hz Max 13Hz PDA Available no Column Compartment Temperature range 4(cooling)-90oC Ambient - 60oC Temperature Stability ± 0.05℃ ± 0.15℃

YL9100 HPLC – Competition vs A Price of YL9100 VS “A” company low cost model YL9100 “A” 1120 Manual Isocratic HPLC system 15,400$ 16,000$ Automatic Quaternary Gradient System 33,700$ 33,000$ Better performance, Same price What is your choice tomorrow?

YL9100 HPLC – Competition vs S Specifications of YL9100 VS “S” company Pro… YL9100 “S” Pro… Degassing 4-channel 3-channel or 5-channel Pumps Isocratic/QLPG/BHPG UV/Vis Detector Wavelength range 190-900 nm 190-700nm or –900nm Baseline Noise ± 0.5 x 10-5 AU at 254 nm 0.5 x 10-5 AU Baseline Drift <1 x 10-4 AU at 254 nm 1 x 10-4 AU/hr Data acquisition rate Max 50 Hz Max 20Hz ?? PDA 1,024 diodes 512 diodes Column Compartment Temperature range 4(cooling)-90oC 4(cooling) - 85oC Temperature Stability ± 0.05℃ 0.1℃

YL9100 HPLC – Competition vs S Price of YL9100 VS “A” company low cost model YL9100 “S” Pro… Automatic Quaternary Gradient System 33,700$ 41,000$ Automatic Binary 36,800$ 47,000$ Same performance, Better price What is your choice tomorrow?