LED Revolution in Lighting ACON LED Revolution in Lighting - Kartik Bakeri Suveg Electronics SYNERGY FOR ENERGY 2012 www.suvegelectronics.com
Company Profile ACON Suveg Electronics, part of Bakeri Group is an ISO 9001:2008 certified company, established in 1985 We deliver market-leading products with improved energy conservation, distinctive styling & accustomed to hostile environmental conditions Many of our innovations are patented & designed to give maximum light output along with enhanced energy saving Testing carried out at UL, & ERDA, as per International Standards www.suvegelectronics.com
LED Revolution in Lighting -This presentation endeavors to give a fundamental outlook on why, where, where not and what’s of LED in the world of lighting. - LED lighting for general illumination - Where to use LED - Efficiency, cost economics and maintenance required - How to select the right LED luminaire? - Knowledge of LM 79, LM 80 EMI/EMC standards and certain thermal aspects - Verification after installation whether the luminary has been delivered as per the specifications promised
Application Efficacy, Cost, Cost of Electricity generation, Life, Maintenance, warrantee as compared to other efficient light sources such as T5, CFL, sodium vapour, induction lamp, etc. Use of lenses increases the usable efficiency So, application in street lights, industrial high bay, solar, table lamps, work bench, sign boards/hoardings, and other task lighting www.suvegelectronics.com
Main Contents of LED fixture LED/s MPCB for the LED/s Heat Sinking Housing Optics and/or toughened glass cover Driver/s (Electronic circuit) – the heart
Standards & Compliance Apart from the general standards like Ingress protection, etc. Specially applicable to LED luminaries : IS 1610X/LM79 and EMC standards LM79 : Luminous characteristics EMC : Compliance to electromagnetic standards www.suvegelectronics.com
IESNA –LM-79-2008 Power consumption Luminous Flux (Lumen) System Efficacy : Lumen/Watt :- 70-80 lm/W is practical at present Power Factor : Preferably greater than 0.98 Field angle and Beam angle CCT & CRI Photometry www.suvegelectronics.com
Correlated Colour Temperature (CCT) & Colour Rendering Index (CRI) CCT : 4000 to 6500 preferable for general illumination CRI : preferably > 70 www.suvegelectronics.com
Asymmetric batwing pattern – Street Light An ideal Polar Curve for the street light www.suvegelectronics.com
Corresponding Light Intensity Data Source: UL Report No. 6012-001708-01-01- ACON SL_90W www.suvegelectronics.com
Road with Angular diagram ¥ = 60° C = 0° ¥ = 30° ¥ = 60° C = 90° ¥ = 60° C = 70° www.suvegelectronics.com
IES file : whether matching IS1944 www.suvegelectronics.com
9 Point Method : A practical approach B C G D F J H Avg Lux= (A+B+C+D)/16 + (E+F+G+H)/8 + J/4 www.suvegelectronics.com
Case Study 9 Point Calculation ACON 65W LED Street Light Road Width: 15m, Height: 8.5m, Spacing: 30m, Angle: 15 Deg Points A B C 1 24 15 2 18 3 13 8 Avg Lux 16 Uo 0.51 Min/ Max > 33% 150W HPSV Road Width: 15m, Height: 8.5m, Spacing: 30m, Angle: 15 Deg Points A B C 1 30 5 2 25 3 11 4 Avg Lux < 15 Uo < 0.4 Min / Max < 33%
EMC Harmonics Emission Immunity Conducted Radiated www.suvegelectronics.com
EMC : Supply Current THD < 10% Supply Current total Harmonics Distortion should be < 10% THD < 10% with low conducted Emission THD < 30% with high conducted Emission Supply Current Waveforms www.suvegelectronics.com
EMC Emission : EN 55015 limits Quasi-peak & Average Limits and obtained Average at mains terminals www.suvegelectronics.com
Immunity as per IEC 61547 Injected current (common mode radio frequency) Fast transient (5/50 ns pulses) Radio frequency Electromagnetic field Surge Test (1.2/50 µsec) ESD (Electrostatic Discharge) www.suvegelectronics.com
IESNA-LM-80 V/s Tj=85º C LED tested @ Tj=25º C www.suvegelectronics.com
Summary Test Reports Physical Verification LM 79 for photometric data THD < 10% Conducted & Radiated Emission as per EN 55015 Immunity as per IEC 61547 LM 80 test for LEDs at Tj =85º C Physical Verification Supply Current Waveform for THD & Conducted Emission Consumption & Power Factor 9 Point Avg Lux measurement www.suvegelectronics.com
ACON Thank You! Email: marketing@suvegelectronics.com ACON LED SL powered by G.E.B. & DG Sets