The Cartridge.

Slides:



Advertisements
Similar presentations
Lesson Identifying Hazards in Agricultural Mechanics.
Advertisements

Unit B: Safety in Agricultural Mechanics
The Armamentarium 4 PARTS: 1) The Syringe 2) The Needle 3) The Cartridge 4) Preparation.
Armamentarium.
What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT.
Local Anesthetics Armamentarium
Preparing the Anesthetic Syringe
Lesson A1-2 Identifying Hazards in Agricultural Mechanics.
Safe Use and Operation of Vacuum Lines
EQUIPMENT IN L.A. Equipment has been developed for LA administration to be convenient in use and to be sterile ( read history). Sterilization: removal.
Lab Equipment. Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
Clinical Calculation 5th Edition
Packaging of injections. Containers for injection ideal properties Does not affect its contents No surface changes at temp. & pressure associated with.
How To Prepare, Sterilize, AND Test Culture Media
Methods for Control of Microbial Growth
Staying Safe in the Shop
DENT 1160 Pharmacology Local Anesthetic 1. Aspirating syringe Has harpoon, so Dr can inject a small amount and pull back to check for blood in carpule.
Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim.
Instrument Processing DA 116 Infection Control
Instrument Processing DA 116 Infection Control. Instrument Contamination Levels: 1. _______________ 2. _____________________ 3. _____________________.
Biology 120 Enzyme Function Exercise 4
First Aid Part 1.
Lab Equipment. Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
Respirator Safety This Training Covers Respirator Inspection User Fit Checks Respirator Cleaning Respirator Storage.
Colorado Agriscience Curriculum
Chapter 2 Matter and Change Unit Notes START IT UP PUP.
Guidelines, Equipment and Supplies for Sterile Compounding
Local Complications in Anesthesia Administration.
Interactive Learning Tool For Patients And Nurses By: Regina Jones.
Using Sterile Technique to Load a Syringe
Copyright © 2006 Thomson Delmar Learning. ALL RIGHTS RESERVED. 1 PowerPoint ® Presentation for Oral Health, Nutrition, and Anatomy and Physiology Module:
Sterilization & Disinfection Physical Agents Hugh B. Fackrell PhysSter.ppt.
Bacterial Transformation Teacher Preparation Sterile Materials.
Administration of Vaccine via Subcutaneous Route Hand hygiene is the first step in medication administration is hand hygiene. Use either an alcohol-based.
Lab Safety Chemistry. Why Lab safety? It is a part of your laboratory experience. Many substances can be dangerous if handled improperly Lab equipment.
Reconstitution of Dryvax® Smallpox Vaccine As taken from the Package Insert, Dec
First Aid. Wounds and Bleeding 1. A wound is a break in the soft tissue of the body.
Recombinant DNA Bacterial Transformation Teacher Preparation Sterile Materials.
Chemical Sterilization
CONTROL OF MICROORGANISMS 1. TOPICS  Sterilization & Disinfection.  Antimicrobial definitions.  Factors influence the effectiveness of antimicrobial.
Standard Operating Procedure for the Preparation and Administration of Injectable medicines in Clinical Areas Prescription, preparation and administration.
ASEPTIC TECHNIQUE IN HEALTHCARE. MICROBIAL GROWTH FOLLOWING FACTORS INFLUENCE MICROBIAL GROWTH: TEMPERATURE PH, OR THE VALUES USED IN CHEMISTRY TO EXPRESS.
STRILIZATION AND DISINFECTION IN A DENTAL CLINIC
Intravenous cannulation
Change of Phase Chapter 23. Topics  Phases  Evaporation  Condensation  Evaporation & condensation rates  Boiling  Freezing  Energy & changes of.
CHAPTER 4 Infection Prevention 4-2 Introduction Infection prevention terminology is required for understanding microbiology in practice ─Infection prevention.
Physical and Chemical Changes. Let’s Review: In A Physical Change.... A substance is changed physically, but not chemically. It is still the same substance.
Sterilization Lab 3 Abeer Saati.
Lesson XIII: Anesthesia
Injectable Medications
Local Anesthesia for the Dental Hygienist
بسم الله الرحمن الرحيم.
CENTRAL STERILE SUPPLY SERVICE
When an ice cube melts, it gains thermal energy.
Science Review #1 Created by Educational Technology Network
6.1 Cracking Learning outcome Explain what thermal and catalytic cracking are Task: answer recap questions.
TEMPERATURE.
A: Dental cartridges. The rubber stopper is on the right end of the cartridge while the aluminum cap with the diaphragm is on the left end of the cartridge.
Laboratory glassware Dr. Ebtihaj Jambi.
Medical Dosage Calculations A Dimensional Analysis Approach
Surgery module – general principles
Special working methods
Chapter 9 Controlling Microorganisms
STATES OF MATTER LEARNING OUTCOMES Chapter 1
Ethanol - Corn Mash and Distillation
CHAPTER 4 Infection Prevention.
Identifying Hazards in Agricultural Mechanics
STATES OF MATTER LEARNING OUTCOMES Chapter 1
When an ice cube melts it gains thermal energy
Ethanol - Corn Mash and Distillation
Presentation transcript:

The Cartridge

Components of the Cartridge The 1.8 ml dental cartridge consists of four parts: 1) Cylindrical glass tube 2) Stopper (Plunger, Bung) 3) Aluminum Cap 4) Diaphragm Carpule = registered trade name for the dental cartridge introduced by Cooke-Waite laboratories in 1920

Parts of the Cartridge -Rubber stopper should be lightly indented -Flush or extruded stoppers: don’t use -Aluminum cap holds the diaphragm in position -Diaphragm is latex rubber through which the needle penetrates the cartridge (no allergies ever reported)

-Liquid can diffuse through the diaphragm and contaminate the local anesthetic solution (alcohol common culprit) -Mylar plastic label surrounds glass with content information and color coded band to identify the anesthetic

Composition of Local Anesthetic Cartridge

What is in the Cartridge? -Local Anesthetic: provides anesthesia; resists heat -Sodium Chloride: produces isotonicity with body tissue -Sterile Water: provides volume only -Vasopressor: increases safety, duration and depth of anesthetic -Sodium (meta) Bisulfite: antioxidant (preservative) -Methylparaben: bacteriostatic agent and antioxidant -only found in multi-dose drugs, ointments, creams -bacteriostatic, fungistatic and antioxidant -removed due to single use and paraben allergies

Care and Handling -local anesthetic drug is stable and can be sterilized, heated, autoclaved, or boiled without being broken down -problem is that the diaphragm and vasopressor is heat labile and can easily be broken down, so cartridges should not be autoclaved -“blister packs” should be stored at room temperature and in the dark -bacterial cultures taken off newly opened “blister packs” produce no bacterial growth when cultured -cartridges are ready to be used when removed from the package there is no need to rub the diaphragm with alcohol -cartridges should not be permitted to soak in alcohol or other sterilizing solutions because the diaphragm will allow diffusion

Cartridge Warmers -cartridge warmers are not necessary; the patient cannot discern between warmed and room temperature local anesthetic -patients do not complain of the local anesthetic solution feeling cold upon injection -local anesthetics that are warmed too much, i.e., > 80 F will be described as too hot or burning upon injection -local anesthetic warmers are deceptive if they claim that the injection will be less painful if the anesthetic is warmed

Problems Bubble In The Cartridge: 1-2 mm bubble can be found in the cartridge which is nitrogen gas that is inserted into the cartridge when it is sealed to keep oxygen out; avoids oxygen oxidizing the vasopressor Extruded Stopper: liquid was frozen at some point leading to extrusion sterile environment of the solution can no longer be guaranteed; it only takes one day for alcohol to diffuse through the diaphragm; alcohol is neurolytic and can cause extended lengths of parasthesia; do not soak cartridges in alcohol

Burning On Injection 1) Normal response to the pH of the drug 2) Cartridge contains sterilizing solution 3) Overheated cartridge (local anesthetic warmer) 4) Cartridge containing a vasopressor (decreased pH) 5) Vasopressor decreases the pH from 5.5 (plain) to 3.3 – 4.0 6) Sodium Bisulfite  Sodium Bisulfate (much more acidic) 7) -ite  -ate occurs by oxidation after local anesthetic expiration -with the addition of silicone as a lubricant around the stopper instead of paraffin this is not a problem anymore

Cracked Cartridge Glass -there is no need to hit the thumb ring with excessive force when engaging the stopper with the harpoon -controlled pressure with the palm of the hand will provide adequate engagement -some have a tendency to engage the harpoon too aggressively which is a bad habit that leads to cracked glass cartridges

Additional Armamentarium 1) Topical Antiseptic: betadine or thimerosal; 8% of Dentists use it and is considered optional; eliminates post-injection infections 2) Topical Anesthetic: disguises the initial introduction of the needle into the tissues when applied for a minimum of 1 minute; if left for 2 to 3 minutes, profound topical anesthesia is achieved; studies have shown that less than 10 seconds does not provide any more anesthesia than placebo

References Malamed, Stanley: Handbook of Local Anesthesia. 5th Edition. Mosby. 2004