Field Testing for Shorted Casings

Slides:



Advertisements
Similar presentations
Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Advertisements

HOUSTON, TEXAS1 Protection of DOT Regulated Pipelines During Construction and Repair Activities ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
Stray currents corrosion of underground steel pipelines
for Pipelines & Casings
AC Mitigation Overview - TGA
Stray and Telluric Current Correction
Corrosion and Cathodic Protection
ECDA Process for Cased Gas Transmission Pipelines
BY John Williams The Tapecoat / Royston Company
STRAY CURRENT CORROSION
Pipeline Current Mapper PCM+
Direct Current Voltage Gradient
AC Mitigation Overview
GTEC 2014 Fall Compliance Conference CATHODIC PROTECTION SYSTEMS Underground Fuel Tanks & Piping Owner Monitoring & Maintenance Requirements.
Presenter: Craig Woolhouse Sales Manager Elcometer Limited
Regional Sales Manager
Pipeline Current Mapper PCM
MElec-Ch1 - 1 Chapter 1 Properties of Electricity Properties of Electricity.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Corrosion Control A PHMSA Perspective Pipeline Safety Trust Conference.
Control of DC and AC Interference on Pipelines
Circuits 6-1.
HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Corrosion Impact of Cathodic Protection on Surrounding Structures
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
NEPTUNE Power System Ground Return Electrodes Tim McGinnis & Colin Sandwith UW/APL.
WESTERN REGION GAS CONFERENCE AUGUST 21, 2012 CORROSION 101
RAILROAD COMMISSION OF TEXAS Steven Rios Corpus Christi Area Manager September 2015.
HEAVY DUTY ELECTRICAL CBC. SIZE IS IMPORTANT! THE LARGER THE ENGINE, THE LARGER THE BATTERY NEEDED. ELECTRICAL SYSTEMS VITAL TO EQUIPMENT OPERATION.
UNDERGROUND CABLE.
Closed Circuits In applications requiring the use of current, electrical components are arranged in the form of a circuit. A circuit is defined as a path.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
Integrity Management: Assessing & Dealing with Pipeline Road Crossings
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
METL 1313 Introduction to Corrosion Lecture2
CORROSION MITIGATION OF A PIPELINE
Grounding the Electrical System
Electric Current and Electrical Energy.
Circuits.
METL 2441 Cathodic Protection Lecture1
CHAPTER 3 Cathodic Protection How It Works.
Basic Corrosion Theory
Grounding the Electrical System
Corrosion Fundamentals
Evaluation Techniques
Basic Corrosion Theory
Evaluation Techniques
Evaluation Techniques
Criteria for Cathodic Protection
CHAPTER 9 Troubleshooting.
Advanced Chapter 1 Pipe‐to‐Soil Potential Surveys and Analysis
PRESENTATION ON AC & DC INTERFERENCE
Current Attenuation and ACVG Surveys Gary Moss
CATHODIC PROTECTION 5,1 INTRODUCTION
EET 323 – Electrical System Design Lecture 9: Grounding
CHAPTER 6 Stray Current Interference.
TRENTON Casing Filler Presentation
Monitoring Cathodic Protection Effectiveness and Record keeping
Pipeline Current Mapper PCM
Corrosion Control and Monitoring
Fundamentals Course Basic Corrosion
Basic Chapter 6 Resistance and Current Measurements
Why Are We Here? I love corrosion (or the lack of corrosion).
Cathodic Protection Measurement Basics
THROTTLE POSITION (TP) SENSORS
Corrosion Control and Monitoring
ABC Company ABC Chemical Complex Engineering Specification
Presentation transcript:

Field Testing for Shorted Casings AUCSC May 2019 System Diagnostics J. Block

DOT Regulations for Natural Gas Transmission Line Title 49 CFR 192 DOT Regulations for Natural Gas Transmission Line Title 49 CFR 192.467 External corrosion control: Electrical isolation –(c) Except for unprotected copper inserted in ferrous pipe, each pipeline must be electrically isolated from metallic casings that are a part of the underground system. However, if isolation is not achieved because it is impractical, other measures must be taken to minimize corrosion of the pipeline inside the casing. –(d) Inspection and electrical tests must be made to assure that electrical isolation is adequate.

DOT Regulations for Hazardous Liquid Lines Title 49 CFR 195.575 (a) electrically isolate each buried or submerged pipeline from other metallic structures, unless you electrically interconnect and cathodically protect the pipeline and the other structures as a single unit. (c) inspect and electrically test each electrical isolation to assure the isolation is adequate.

NACE Standard SP0169 Requirements 10.4.4 effectiveness of isolating fittings, continuity bonds, and casing isolation should be evaluated during periodic surveys. This may be accomplished by electrical measurements.

NACE Standard SP0200 Requirements 6.2 Monitoring: One or more of the following basic electrical test methods should be used to monitor pipelines and casings on an annual basis. –6.2.1 Potential Survey –6.2.2 Internal Resistance –6.2.3 Four-Wire IR Drop –6.2.4 Cycling Rectifier –6.2.5 Casing Depolarization –6.2.6 Direct Resistance Measurement –6.2.7 Pipe/Cable Locator

Casing Testing: One LDC Approach

CIS Pipe-to-Soil Survey

CIS Survey - 0.90 - 0.68 - 0.65 - 0.71 - 0.73 - 0.69 - 0.70 - 0.78 - 0.95 - 0.96 - 0.72 - 0.93 - 0.83 NACE International (National Association of Corrosion Engineers) recommends connection to the structure under test (pipeline) in this convention. Steel pipe

- 0.95 - 0.85 - 0.75

- 0.98 - 0.90 - 1.47 - 0.44 - 0.93 - 0.52 - 0.11 - 0.33 - 0.77 - 0.22 - 0.95 - 0.66 - 0.71 - 0.83 - 0.23 - 0.85 - 1.67 - 0.93 - 0.69 - 0.65 - 0.50 - 0.68 Steel pipe Steel pipe

Coated Steel Pipe with coating defects The effects of stray current from an electrified transit system can be extremely detrimental to buried metallic structures in the vicinity of the rail tracks. A well coated pipeline can reduce interference current from entering or exiting the pipe surface. Defects in the coating (coating holidays) can provide a path for stray current damage to the pipeline. Coated Steel Pipe Coated Steel Pipe with coating defects

Casing Test: C = clear E = electrolytic M = metallic Structure-to-soil readings that have similar value may indicate an electrolytic condition or metallic short between the pipe and casing. Structure-to-soil readings that have the same value may indicate a metallic short P/S C E M DC Voltage Shift DC current applied to one structure drives the other structure more negative, may indicate a metallic short. DC current applied to one structure drives the other structure less negative or none, indicates a cleared casing C E M PΩ-earth & CΩ - earth Calculated resistance to earth values that are similar may indicate an electrolytic condition. Calculated resistance to earth values that have the same value may indicate a metallic short C E M Calculated resistance between pipe and casing that is ≤ to 1 Ω may indicate an electrolytic condition or possibly a metallic short. If resistance value is ≤ the sum of the pipe-to-earth and casing-to-earth, this may indicate an electrolytic condition or metallic short. PΩ - CΩ C E M Application of a signal locator between the casing and the pipeline that is greatly reduce or lost may indicate a metallic short. Application of a signal locator between the casing and the pipeline that is maintained along the pipeline indicates a cleared crossing. Signal Locator C E M Head-Set Connecting a head-set between the casing and the pipeline will present an audible tone. Tone indicates a voltage potential which may indicate a cleared casing or an electrolytic condition. Lack of an audible tone may indicate a metallic short. C E M

Structure to Soil Potential Structure-to-soil readings that have similar value may indicate an electrolytic condition or metallic short between the pipe and casing. Structure-to-soil readings that have the same value may indicate a metallic short

- .71 - .76

DC VOLTAGE SHIFT DC current applied to one structure drives the other structure more negative, may indicate a metallic short. DC current applied to one structure drives the other structure less negative or none, indicates a cleared casing

- 0.87 - 0.73 - 0.76 - 0.76 External Current Source Temporary Ground Bed

- 0.70 - 0.71 - 0.95 - 0.71

Pipe Ω-earth & Casing Ω-earth Calculated structure resistance-to- earth values that are similar may indicate an electrolytic condition. Calculated structure resistance- to- earth values that have the same value may indicate a metallic short

AMPS I On Off ∆ V Ω I On Off ∆ V Ω 3.01 - 1.30 - .76 .54 .18 2.96 - 0.76 - 1.30 - 1.18 - 0.71 External Current Source Temporary Ground Bed AMPS I On Off ∆ V Ω I On Off ∆ V Ω 3.01 - 1.30 - .76 .54 .18 2.96 - 1.18 - .71 .47 .16

Pipe Ω vs. Casing Ω Calculated resistance between pipe and casing that is ≤ to 1Ω may indicate an electrolytic condition or possibly a metallic short. If resistance value is ≤ the sum of the pipe-to-earth and casing-to-earth, this may indicate an electrolytic condition or metallic short.

Clear

Casing and Carrier Clear -0.05 -1.59 1.12 Battery Casing and Carrier Clear I On Off ∆ V Ω 1.12 - 1.59 - .05 1.54 1.39

Electrolytic

Possible Electrolytic condition between Casing and Carrier -0.05 -1.02 1.28 Battery Possible Electrolytic condition between Casing and Carrier I On Off ∆ V Ω 1.28 - 1.02 - .05 0.97 .75

Shorted

Suspect Metallic Short between Casing and Carrier -0.76 -0.03 3.89 Battery Suspect Metallic Short between Casing and Carrier I On Off ∆ V Ω 3.89 - 0.76 - .03 0.73 .18

Soil Resistivity Meter P 1 P 2 C 2 C 1

Signal Locator Application of a signal locator between the casing and the pipeline. A signal that is greatly reduced or lost, may indicate a metallic short. Application of a signal locator between the casing and the pipeline that is maintained along the pipeline indicates a cleared crossing.

Brand X Pipe & Cable Locator

ACVG

700 A 600 A 500 A 400 A

700 A 600 A 500 A 400 A

Vent Line or Coating Holiday ?

Head-Set Connecting a head-set between the casing and the pipeline will present an audible tone. Tone indicates a voltage potential which may indicate a cleared casing or an electrolytic condition. Lack of an audible tone may indicate a metallic short.

Battery

Gas Main 90 ° at top Gas Main 90 ° at bottom Steam Conduit 170 ° Ground Water 120 °

54” Casing 12” Casing 8” Gas Main Support Bracket 32” Steam Conduit 6” Condensate Line 12” Steam Pipe