SuperB Linac Beam Position Monitor

Slides:



Advertisements
Similar presentations
Physical Layer: Signals, Capacity, and Coding
Advertisements

ATF2: Status Update Glenn Christian (on behalf of FONT group) 10 th ATF Project Meeting.
M.Gasior, CERN-AB-BIBase-Band Tune (BBQ) Measurement System 1 Base-Band Tune (BBQ) Measurement System Marek Gasior Beam Instrumentation Group, CERN.
Update of EXT Stripline BPM Electronics with LCLS-style Digital BPM Processors Glen White, with slides by Steve Smith 15 December 2009 ATF2.
S. Smith LCLS Facility Advisory April 16, BPMs and Toroids Facility Advisory Committee April 16, 2007 System overview.
20 Feb 2002Readout electronics1 Status of the readout design Paul Dauncey Imperial College Outline: Basic concept Features of proposal VFE interface issues.
Ron Johnson Beam Position October 29-31, Beam Position Monitors FAC Review October 29-31, 2007 Stripline BPM.
HIAPER Cloud Radar Transceiver Exciter Receiver Oscillators High-Powered Amplifier Calibration Exciter Receiver Oscillators High-Powered Amplifier Calibration.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Digital Correlated Double Sampling for ZTF Roger Smith and Stephen Kaye California Institute of Technology The digital equivalent of dual slope integration.
ATF2 Q-BPM System 19 Dec Fifth ATF2 Project Meeting J. May, D. McCormick, T. Smith (SLAC) S. Boogert (RH) B. Meller (Cornell) Y. Honda (KEK)
High Resolution Cavity BPM for ILC final focal system (IP-BPM) ILC2007/LCWS 2007 BDS, 2007/6/1 The University of Tokyo, KEK, Tohoku Gakuin University,
Status of ATF2 Cavity BPM Project Sep 29, 2005 Project Scope: Instrument both couplers ATF2 cavity BPM’s (35) Produce prototype for December cavity test.
FJPPL-FKPPL Workshop on ATF21 FONT digitisation studies of IP BPMs D. Bett, N. Blaskovic, P. Burrows, G. Christian, M. Davis, Y. I. Kim, C. Perry John.
IP-BPM status Siwon Jang KNU. Contents The electronics repair status –Repair work status –Electronics RF test (by using Oscilloscope) –Electronics shipment.
SPECTRUM ANALYZER 9 kHz GHz
Future FONT BPM Processors C.Perry 25 June Types of Processor Two types of processor: a) present mixer type b) baseband type Both will be made because:
Frank Ludwig, DESY Content : 1 Stability requirements for phase and amplitude for the XFEL 2 Next LLRF system for optimized detector operation 3 Limitations.
LCLS_II High Rep Rate Operation and Femtosecond Timing J. Frisch 7/22/15.
IP BPM Shift Report FONT Meeting: 22 December 2014 Talitha Bromwich.
Results on recent technology developments at ATF - Beam extraction study by a Fast Kicker - N. Terunuma, KEK LER11, Heraklion, Crete, Greece, 2011/Oct/5.
F Beam Line Tuners Vic Scarpine Instrumentation DoE Review Oct 28-31, 2002.
Beam Position Monitors for the CLIC Drive Beam CLIC Meeting 21 January 2011 Steve Smith.
FONT Hardware Processing electronics and current beam tests Stephen Molloy Queen Mary, University of London.
Beam Line BPM Filter Module Nathan Eddy May 31, 2005.
Superfast BPM Processor Scheme and First Results Stephen Molloy, QMUL 2 nd Mini-Workshop for Nano-Project at ATF.
1 ATF 2 Nanobpm (Q BPM) Electronics. Mark Slater: Cambridge Yury Kolomensky, Toyoko Orimoto: UCB Stewart Boogert, Steve Malton, Alexi Liapine: UCL Mike.
SLAC ESA T-474 ILC BPM energy spectrometer prototype Bino Maiheu University College London on behalf of T-474 Vancouver Linear Collider.
Specifications of Tevatron BPM Upgrade Jim Steimel.
ATF DR BPM Upgrade Janice Nelson, Doug McCormick, Justin May, Andrei Seryi, Tonee Smith, Mark Woodley.
NLC - The Next Linear Collider Project Nano beams in the ATF extraction line Marc Ross Linear collider challenges: Energy Emittance source Stability ATF.
High precision phase monitoring Alexandra Andersson, CERN Jonathan Sladen, CERN This work is supported by the Commission of the European Communities under.
LCLS Digital BPM Processor for ATF2 Extraction Line BPMs Steve Smith 26 August 2009.
Interferometric Residual Phase Noise Measurement System Pakpoom Buabthong Lee Teng Internship Program Advanced Photon Source Accelerator System Division,
S. Smith LCLS Facility Advisory October 12, Beam Position Monitors Facility Advisory Committee October 12, 2006.
U. Iriso ESLS XXIII Nov Commissioning of the Bunch By Bunch Feedback System U. Iriso, J. Moldes, A. Olmos (ALBA – CELLS) M. Abbot, G. Rehm (Diamond)
Beam Secondary Shower Acquisition System: RF design techniques for 40MHz ADC Student Meeting Jose Luis Sirvent PhD. Student 30/09/2013.
Superfast BPM Processor Scheme Stephen Molloy, QMUL Nano-Project Mini-Workshop at ATF.
DAQ ACQUISITION FOR THE dE/dX DETECTOR
Beam Commissioning Adam Bartnik.
Beam Secondary Shower Acquisition System: Front-End RF Design
Communication 40 GHz Anurag Nigam.
LCLS_II High Rep Rate Operation and Femtosecond Timing
Multi-bunch Operation for LCLS, LCLS_II, LCLS_2025
Glen White, SLAC Jan th ATF2 Project Meeting, KEK
Alternative BPM Processing Scheme – May08 Demo
NanoBPM Progress January 12, 2005 Steve Smith.
For Discussion Possible Beam Dynamics Issues in ILC downstream of Damping Ring LCWS2015 K. Kubo.
Emittance Dilution and Preservation in the ILC RTML
5 months of experience with 8 units of Libera Brilliance
96-channel, 10-bit, 20 MSPS ADC board with Gb Ethernet optical output
P. Forck, P. Kowina, M. Schwickert, R. Singh
Design of Digital Filter Bank and General Purpose Digital Shaper
Intra-Pulse Beam-Beam Scans at the NLC IP
Bunch Tiltmeter Steve Smith SLAC Snowmass July 16, 2001 Update date
Low Level RF Status Outline LLRF controls system overview
NanoBPM Status and Multibunch Mark Slater, Cambridge University
BESIII EMC electronics
Beam Current Monitoring with ICT and BPM Electronics
Low Level RF Status Outline LLRF controls system overview
Spectral Control Issues for TGg
Status of TTF HOM Project Aug 9, 2005
Report on ATF2 Third Project Meeting ATF2 Magnet Movers ATF2 Q-BPM Electronics Is SLAC ILC Instrumentation Group a good name?
High Level Physics Applications for LCLS Commissioning
Undulator Cavity BPM System Status
SuperB Linac VME Beam Position Monitor
Undulator Cavity BPM Status
Breakout Session SC3 – Undulator
Head-Tail Monitor for CC Diagnostics
Beam Position & Charge Monitors LCLS Lehman Review July 11, 2007
Presentation transcript:

SuperB Linac Beam Position Monitor Steve Smith KEK 28 May 2013 Update date Multibunch (ATF) results) Chip status Delete costs Get better drawing of cavity More details of cavity BPM scheme

Acknowledgements Thank you for your hospitality! Developments It has been a great pleasure to visit KEK and work with all of you. Kazuro Furukawa, Ryo Ichimiya, Fusashi Miyahara, Masanori Satoh, Tsuyoshi Suwada, other people Looking forward to continued collaboration Developments Congratulations on progress so far Much work completed Great to get beam test results on short notice Two solutions appear likely to meet requirements At least for single bunch And immediately after meeting we start looking at synthetic 2 bunch data.

Charge Review linac beam position monitor development Suggest: possible improvements how to evaluate performance Path forward

Overview Scope Requirements ~100 stripline BPMs in linac Requirements Beam charge range: 0.1 to 5nC (10 nC?) Resolution xy < 10 microns at 1 nC <100 microns at 0.1 nC Scale: 10 micron resolution requires measurement to ~0.2% Two bunches at 96 ns separation Schedule Demonstrate performance by fall 2013 Order production units January 2014 Start commissioning Oct 2014

Nanobeam Scheme Excellent alignment stability of postion Emphasis on emittance preservation requires Excellent alignment stability of postion stability of BPM calibration Avoidance of wakefields  resolution of 2 bunch measurement Detect / correct wakefield effects

Costs I cannot compare cost of systems Recommend: too many variables to grasp in a short visit Recommend: At least consider other commercial ADCs VME or microTCA From Struck, Echotech, or other source

Overall Recommendations Evaluate: Noise Effective number of bits (ENOB) Front-end noise Linearity Third-order intercept (IP3) Set attenuators to optimize noise vs. linearity Understand signal level at every potentially non-linear stage Important for stability with clock phase variation Stability with beam current variation Study: Position algorithm Calibration 2-bunch algorithm Document procedures

Overall Recommendations (2) Need additional staff to: perform studies, Develop algorithm grad student or post-doc? maybe 2 additional people Need synchronous acquisition of BPMs, other pulse-pulse diagnostics Very difficult to understand jitter, drift, optics without synchronous asquisition linac is a different machine every pulse when you look at high resolution

Evaluate ADC Noise Does ADC deliver expected performance? Procedure VME ADC noise level without signal matches ADC spec Evaluate with signal present Useful for Libera or VME Procedure Inject signal from generator at level -1 dBFS Through bandpass filter if possible to remove harmonics Acquire data Fourier transform Remove DC, center frequency Inverse transform Evaluate rms noise Missing bits = log2(rms*sqrt(12)) Effective bits = Nbits- missing bits Or fit data to sine function and subtract fit to get residual noise Can measure with and without head Amp / Libera front end

Evaluate Linearity Linearity crucial for stability against Clock phase Beam charge variation Assume linearity well-characterized by third-order intermodulation performance Measure Third-order intercept (IP3) Inject 2 tones (F1 & F2) separated by a few MHz through combiner Each tone at Full scale -7dB (so sum doesn’t saturate) Evaluate spectral components at 2*F1-F2 and 2*F2-F1 Either by digitizing with ADC and fft Or spectrum analyszer on analog signal

Libera “Brilliance” Advantages Disadvantages Demonstrated resolution < 10 microns Includes timing (EVR) EPICS driver exists Disadvantages No online calibration Must measure offsets as function of attenuator setting Load into calibration tables Repeat how often? Impulse response has more tail > 96 ns than VME Requires precise phase alignment of BPM signals

Phase Matching Libera requires phase matching requires 5ps matching to get 10 micron resolution Resolution slope ~ 3 microns/ps Why? Not summing over entire waveform? Nyquist band edge violation? Phase matching is time-consuming Rough matching with cable extension Fine tuning with phase shifter Phase shifter changes attenuation Causes position offsets Concern that phase matching implies matching of filter phases as well

Further Steps for Libera Measure ADC resolution How many effective bits? Linearity Measure IP3 Can Third-order products be 60 dB below signal? signal < IP3 – 30 dB Evaluate 2-bunch performance Frequency is not optimum F=522 MHz (near peak of stripline response) But cable loses ~ 10dB at 522 MHz Maximum signal is at lower frequency Cannot calibrate with stripline-to-stripline coupling (coupling = 0 at 522 MHz) Recommend lower frequency Maybe 200 MHz or 320 MHz

Linac-Specific VME Module VME module integrating Head Amp & ADC Should yield few micron resolution from design NEW: Measure ~10 micron resolution with low-charge beam Issues: ADC shows “glitch” every 10th sample Fix: Adjust ADC to FIFO timing Limit bandwidth of signal to ADC Causes loss of ~-14 dB at 300 MHz Expect resolution <10 microns from design Measure ~22 microns with calibration tone Measure  ~60 microns with impulse-like tone Need to understand why resolution isn’t as expected Needs EPICS driver

VME Recommendations Understand why resolution isn’t as expected ADC input network? Is ADC noise low enough? Is ADC linearity good enough? Filter response Tails extending across Nyquist zone boundaries? 2nd passband in filter response at 900 MHz? Verify ADC performance Noise (enob) Linearity (IP3) Verify Head Amp / Bandpass Filter performance Noise (nV/sqrt(Hz) or dBm/Hz) with spectrum analyzer, or through ADC

VME Recommendations (2) Change input bandwidth to center frequency 180 MHz (now it is 300 MHz) This lowers Q of filters Plenty of signal to noise Works better with ADC input network Improve filter response Keep tails of filter response below -50 dB at Nyquist zone edges (if possible) Remove 2nd passband near 900 MHz Improve ADC input network Maintain response to 200 MHz then roll off Understand algorithm How many samples should be included? How should attenuators be set to optimize noise vs. non-linearity? Keep signal levels < IP3 – 30 dB (3rd order products < -60 dB)

VME Recommendations (3) Possibly improve head amp noise figure This is low priority, not very important Already better than needed for required resolution

Measuring Two Bunches Two-bunch performance is important for identifying and correcting wakefield kicks Measurement of two bunches not yet demonstrated Recommendations: Beam test Create artificial 2nd bunch with splitter, delay, combiner Expect to measure same position of two bunches Offline synthetic 2nd bunch Record waveforms from single bunch beam Add signal from opposite strip, delayed by 96 ns Expect 2nd bunch position opposite of 1st. Test with 2 bunch beam as soon as possible

Time-Domain Response Libera: VME:

Comparison Feature Libera VME Comments Single bunch resolution Good Two-bunch resolution Not demonstrated See impulse response Impulse response ~20% @ 96 ns 3% @ 96 ns VME much cleaner Calibration Static, invasive, Must generate table with offset vs. attenuator Dynamic, potentially continuous Calibration very important System integration Chassis includes EVR, processor, multiple BPMs? VME crate Processor EVR Multiple BPMs Cost? EPICS integration Driver exists Needs driver Cost, time Development environment Access to Libera develop, modify algorithms

Risks How open is Libera processor for algorithm development? Cost? Schedule One turn of design & evaluation by December Who will develop 2 bunch algorithm? What if 2 bunch algorithm doesn’t meet requirements? Add one (or a few) dedicated wakefield detectors For example fast scope like existing system But preceded by ringing filter and analog difference/sum hybrid to increase resolution by x16 3 bits for ringing time of 60 ns 1 bit for hybrid

Recommendation Both solutions appear to meet single bunch resolution requirement Neither demonstrates 2 bunch performance yet VME time domain response looks better for 2 bunch measurement Libera appears to have noise floor just below 10 microns Limited by phase matching VME should get much better than 10 micron resolution at 1 nC Presently limited by ADC input network, possibly excess noise Calibration is very important VME can calibrate frequently (or continuously) Suggest SuperB pursue VME solution

Thank you