Red Team Final Presentation December 8, 2008
Fire Safe Microwave 2
Overview Background Microwave Features Technical Components Business Model Summary 3
Unsafe Microwaves 4
Microwave Features Detects spark and/or fire 1.Alerts user of danger 2.Shuts down microwave 3.Extinguishes flame with CO 2 4.Notifies user when unsafe to open door 5.Indicates when CO 2 cartridge needs to be replaced 5
Product Demonstration 6
7
Component- Circuitry Digital control system with photodiode sensing Check for Spark Spark Detected Check for Fire Fire Detected Stop Microwave Alert User Suppress Fire Alert User 8
Component- Fire Suppression Cartridge Punctured Solenoid CO 2 Cartridge Spring CO 2 Released 9
Component- CO 2 Flow Switch Reset Button CO 2 Electrical Continuity CO 2 Breaks Continuity 10
Testing- Schlieren Flow Visualization for CO 2 Nozzle 11
Testing- Schlieren Flow Visualization for CO 2 Nozzle 12
Component- User Interface 3 surveys with over 300 responses Final design LED Light System Auditory Alarm 13
Business Model Market Fire Safe Technology to OEM through product license 14 VersionSurvey: Price People Will Pay Manufacturing Cost to Add Feature Expected Profit Standard$17$2.30$14.70 Deluxe$30$16.20$13.80
Price and Cost 15
Market Penetration 16
Expected Revenue 17
Fire Demonstration 18
Fire Demonstration 19
Acknowledgments Professor David Wallace Instructors: Kim Vandiver, Matt Duplessie Mentors: Anna Shih, Jon Evans, Pamela Siska Papallardo Staff Instructors, TAs, Mentors, Staff, Maureen Lynch 20
Questions or Comments? 21
Back Up Slides 22
Circuit Diagram 23
Component- CO 2 Flow Switch Reset Button CO 2 24
25
26