Capacity validation, renominations and within-day capacity purchase

Slides:



Advertisements
Similar presentations
IUK view of LT UIOLI NGG EU Workgroup 03/04/14. CONFIDENTIAL IUK view of LT UIOLI: 3 processes ProcessFrequencyPartiesInformation.
Advertisements

Project Nexus Workgroup Unique Sites 4 th November 2014.
UNC Modification Proposal 0116 Reform of the NTS Offtake Arrangements Transmission Workstream 5 th October 2006.
2nd GTE Conference Copenhagen, September 2004 Author:Milan Sedlacek SPP (Slovak Gas Industry) Slovak Republic GAS TRANSIT THROUGH A NEW EU MEMBER STATE.
EU Workgroup – Mod 500 Action 703 – confirm current capacity surrender process.
EU Gas Balancing Code – Nomination Update [Revised to reflect action TX1002] Action TX1002: EU Balancing Code/Nominations: Provide an overview of what.
CRC Energy Efficiency Scheme How to Surrender Allowances GEHO0312BWGC-E-E Last Updated: 31/05/2013 v3.
Performance Assurance 21 st May Value Chain. Value Chain Xoserve would like to propose an approach to further aid the development of the Performance Assurance.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
Mod 270 Potential Options Rob Hill 15/02/2009. Six potential options following discussion at last months Development Workgroup OptionNameDescription 1Elective.
1 Mod Review Group 126 Mar 2007 slides 126 Review Group – Restriction of Invoice Billing Period  The review proposal is primarily concerned with restricting.
Place your chosen image here. The four corners must just cover the arrow tips. For covers, the three pictures should be the same size and in a straight.
MOD0164 Bi-Directional Connection Point Overrun Charge Calculation Stuart Waudby (Centrica Storage Ltd.)
UNC Modification Proposal 0380 Periodic Annual Quantity Calculation Calculation of Daily Supply Point Capacity Alan Raper – DNCMF 26 th September 2011.
1 24 th November 2015 Videoconference 34 th IG Meeting South Gas Regional Initiative.
EU Phase 2 Delivery & UK Link Programme; Impacts on Gemini Process European Workgroup 1 st May 2014.
1 Modification 0152V Implementation Matters 25 October 2007.
Nominations PEA Meeting October Why ask for Nominations? In a common carriage system gas flows must be approved in advance to keep them within pipeline.
Aligning the Gas and Electric Markets: EDF Solutions
Fuel Cost Components in the Fuel Adder
Congestion Management
Fuel Cost Components in the Fuel Adder
Workgroup meeting October 2014
Fuel Cost Components in the Fuel Adder
Proposer: Matthew Hatch Panel Date: 20/10/16
Demand forecast and network balancing
Energy Day Strawman Proposal
Capacity Conversion – 616s
Review of Demand Estimation Times for Modification Proposal 461
IG meeting, December 5th, 2012, DERA premises, Copenhagen
20th April 2016 Teleconference
CMP Transparency Requirements
Project Nexus Workgroup (Settlement)
20th April 2016 Teleconference
Engineering Economics
GTAC Workshop – 17th November
Gas-Electric Coordination Can New Services Bridge the Divide?
Vetting the GENESYS Model
20th April 2016 Teleconference
Transparency Project GRI NW Region.
European Transparency Requirements
Proposer: National Grid NTS Panel Date: 17th April 2014
GTAC Workshop 19 September.
2 hour / 5% Rule Bethan Winter.
UNC Modification Proposal “Allocation of Daily NTS Entry Capacity Within-Day” Richard Fairholme.
PARCA Security and Termination Amounts
Demand management options on the Vector pipeline system
Background to National Grid’s Baseline analysis
Enduring Offtake Arrangements (Including an alternative daily interruptible capacity release mechanism to facilitate use of spare capacity) Peter Bolitho.
DN OAD Processes: RG 0316 : Offtake Workstream
Mod_38_18 Limitation of Capacity Market Difference Payments to Loss Adjusted Metered Quantity. 12th December 2018.
Modification 501 slides for Workgroup
Flow Swap Scenarios – Agreed Logic
UNC Transmission Workstream 15th June 2005
PN UNC Workgroup (Settlement topic)
Entry Overrun Calculation
EU Codes: Implementation Issues
Nexus Workgroup Winter Consumption and the influence on Winter Annual Ratio (WAR) Bands 8th January 2014.
Optimisation of Entry Capacity Modification Proposal
Modification 501 slides for Workgroup
Workgroup meeting October 2014
CAM: Next Steps UNC Transmission Workgroup Lisa Martin 9 January 2014.
Review Group 221: Review of Questions from Session 2
Proposed Changes to UNC Section Q Emergencies - Mod 035
Nexus Workgroup Read Validation Scenarios
Entry Capacity Transfers - Constrained Period
Actions Updates Action 0282/006 – Exclude from AQ process
Nominations 11 July 2014.
Enabling Large Scale Utilisation of Class 3
and Forecasting Resources
Presentation transcript:

Capacity validation, renominations and within-day capacity purchase EU Workgroup 7 August 2014

Capacity and Nominations Intend to maintain current rules, no proposed changes Hourly vs daily regimes IUK Shippers have bought hourly capacities and can nominate either daily or hourly IUK confirmed quantities and allocations are calculated hourly NGG Shippers nominate a daily quantity Capacity validation IUK Shipper nominations are validated against capacity entitlement IUK Shipper nominations for any hour must not exceed their capacity rights for that hour NGG does not validate against capacity, except during exceptional events Today – slides to illustrate how the two regimes work in parallel

Example 1 Day-Ahead Shipper nominates 120 units against their daily NGG capacity of 240 units and nominates 5 units per hour against their hourly IUK capacity of 10 units per hour IUK carries out capacity validation on nominations to ensure the IUK Shipper has sufficient hourly capacity, and constrains IUK Shipper nominations to their capacity entitlement Time NGG Capacity NGG Nom IUK Capacity IUK Nom 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 240 units 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 17:00 18:00 19:00 20:00 21:00 22:00 23:00 00:00 01:00 02:00 03:00 04:00 240 units Daily 120 10 5

Example 1 continued… Within-Day Shipper renominates upwards to use all its capacity entitlement from 17:00 NTS Shipper can nominate 240 units; IUK Shipper can only nominate maximum hourly capacity, i.e. 10 units per hour for the remainder of the day Renominating to maximum level means total allocation by end of day of: 180 units , so should nominate 180 units of NGG capacity Time NGG Capacity NGG Nom IUK Capacity IUK Nom 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 240 units 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 17:00 18:00 19:00 20:00 21:00 22:00 23:00 00:00 01:00 02:00 03:00 04:00 240 units Daily 120 180 10 5 10

Example 2 Day-Ahead NTS Shipper nominates 120 units against their daily NGG capacity of 240 units and profiles their Interconnector nominations, using a total of 120 units IUK capacity IUK carries out a capacity validation on each hourly nomination to ensure IUK Shipper has sufficient capacity Time NGG Capacity NGG Nom IUK Capacity IUK Nom 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 240 units 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 17:00 18:00 19:00 20:00 21:00 22:00 23:00 00:00 01:00 02:00 03:00 04:00 240 units Daily 120 10 7.5

Example 2 continued… Within-Day IUK Shipper renominates upwards to use all its capacity entitlement from 19:00 Already allocated 35 units – cannot change this Can renominate up to 10 units/hour for remaining 10 hours of the day Renominating to maxiumum level means total allocation by end of day of 135 units, so should nominate 135 units of NGG capacity Time NGG Capacity NGG Nom IUK Capacity IUK Nom 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 240 units 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 17:00 18:00 ………………… 19:00 20:00 21:00 22:00 23:00 00:00 01:00 02:00 03:00 04:00 240 units Daily 120 135 10 7.5 7.5 10

Example 3 – Purchasing NGG capacity within day Shipper has 120 units of NGG daily capacity and 10 units/hour IUK capacity Shipper wants more NGG capacity from 17:00 within day Already allocated 20 units, and has 10 units per hour of IUK capacity available for the remainder of the day, therefore: cannot flow more than 140 units, so should only buy max 20 NGG units Time NGG Capacity NGG Nom IUK Capacity IUK Nom 05:00 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 120 units 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 06:00 07:00 08:00 09:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 120 units across the day 10 5 Time NGG Capacity NGG Nom IUK Capacity IUK Nom 17:00 18:00 19:00 20:00 21:00 22:00 23:00 00:00 01:00 02:00 03:00 04:00 120 + 20 effective 17:00 units Daily 140 10 7.5 10

Process of buying Within-Day Capacity