TOP Z WILO Top Z Commercial Wet Rotor Training

Slides:



Advertisements
Similar presentations
50Hz Stainless steel Vertical multistage centrifugal pumps
Advertisements

Water Source Heat Pump Systems
Motorized Pulley Presentation
AUTOMOTIVE COOLING SYSTEMS
Chapter 3. HVAC Delivery Systems
Packaged Terminal Air Conditioners
We dont just go with the flow, we create it.. Introduction to Chemflo and FRX Do your customers use 316 SS end suction centrifugal pumps? Do you need.
GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial.
Preferred Utilities Manufacturing Corp.
Efficient Solutions For Water Supply Helix High-Pressure Vertical Multistage Pump.
USER MAINTENANCE.
Wet Rotor Circulating Pump Twin Tee Wet Rotor Circulating Pump Twin Tee Eliminate: Control valve Control valve Balance valve Balance valve.
HT Series – High Temperature Technology 1 INTERPUMP GROUPS NEW PUMP LINE FOR CAR WASH AND INDUSTRIAL APPLICATIONS UP TO 85°C (185° F)
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International dept. STAR 24 3 E.
Jack Mc Gowan, CEM Optimize operating cost for cooling Improve Capital Projects Improve learning environments GHP Best Practices Geothermal Heating and.
Service Export VICTRIX. VICTRIX Instantaneous boiler  VICTRIX 26 2 I Heating only prearranged for external cylinder connection  VICTRIX X 12 2 I  VICTRIX.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Refrigerators.
SERVICING EVAPORATIVE
Introduction To Zoeller Engineered Products August 2009.
What is a centrifugal pump?
Reservoirs Covered in Ch. 5 of Vickers Text
Engineer Presentation
Introduction to FLUID COPLING.
Dennis Sabre Fire Appliances
GD150 Liquid bulk contactless compressor. GD150 Compressors.
Goulds ISO Series ISO End Suction Centrifugal Pump
Product Introduction.
AccuMax Multi-Point Injection Mechanics
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
Water piping design.
HVAC523 Circulator Pumps.
Settings & Adjustments. Settings & Adjustments.
Stratos ECO Training ECM “Smart” Circulators for Heating, DHW Recirculation Systems Presentation Date – New Jan 2008 ECO 16 FECO 16 FX ECO 16 BFX Stratos.
INTRODUCTION: The internal gear pumping principle was invented by Jens Nielsen, one of the founders of Viking Pump.Jens Nielsen Manufacturers  Viking.
WILO MVI Vertical Multi-Stage Pumps Multi-Stage Pumps for Commercial, Municipal and Industrial Applications Presentation Date – Revised Sept 2006.
CHILLED WATER AIR-CONDITIONING SYSTEMS
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject :Fluid Power Engineering Topic :Rotodynamic Pumps.
Large Tonnage Chiller AC Screw. Content Mechanical System Key Components Control Logic Application 2.
CUE – Make Any Pump an E-Pump
Grundfos CM, CME Pumps CM Pumps Horizontal multi-stage pumps
OILGEAR PVV PUMPS PVV 200 Performance Curves.
PUMPS.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
SYSTEMS. Pumps Systems Our systems are identified as follows Example: model D-CPS-HT-1000-VFD Dis for Duplex units CPSis for Constant Pressure System.
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
Ullrich, DESY Dubna GDE XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Water cooling XFEL Desingn of the XFEL water cooling.
Novomet. BOOSTER PUMPING SYSTEM.
310 Series Inline End Suction
Endsuction Pumps Model LS
Optimum Pump Performance for Process Applications
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
System One Pumps S1-101 Construction and Features
© Copyright, HQT-SV Control System
HIGH PERFORMANCE PRESSURE SYSTEMS.
10TR Nominal Glycol Chiller
SB Packing Automatic Downpuller Power Unit
VED and VEDI VED and VEDI.
Chapter 14 Cooling System.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Presentation transcript:

TOP Z WILO Top Z Commercial Wet Rotor Training Commercial Multi - Speed Wet Rotor Circulators for DHW Recirculation Presentation Date – New October 2008 TOP Z

Overall Features and Benefits TOP Z WILO Brain “Easy Read” Numbering System References flange size and shut off head (max speed) Shortest “Lay Length” in the Industry Industry Standard Flanges 2 Bolt Oval for 1 ½” and 1 ¼” Special “non - ANSI” 4 bolt for 2” 125 # ANSI for 3” Cast Aluminum Terminal Box NPT Electrical Openings Built in Thermal Overload Sensor Rotation Indicator (3 Phase Only) ¼” Suction & Discharge Gauge Tappings Excellent Commercial Pump Warranty 24 months from manufacturing, 18 months from installation

Overall Features and Benefits TOP Z con’t Lead Free Bronze (Cast Iron Version NOT Available) Complies with NSF 61 Engineered Composite Impeller Compatible with softened water Wet Rotor “Seal less” Design Multiple Speed No Mechanical Seals No Couplings No Maintenance! Redesigned Rotor/Can Assembly Built in internal check valve Eliminates internal fluid transfer Eliminates calcium build up Lead free bearings Automatically Vented

WILO Top Z Model Number System TOP Z 1.5 x 25 TOP Z “Z” Lead Free Bronze (no cast iron version) Multiple speed 1.5 Flange size in Inches 3” - ANSI, 125 # raised face, 4 bolt 2” pump flange - 4 bolt “grooved” pump type 1 ½” and 1 ¼” pump flange - oval 2 bolt “grooved” type 25 Approximate maximum pumping head in feet (@ max speed)

Top Z Technical Specifications System Temperature Minimum (all applications) 14 Deg F (-10 Deg C) Maximum Temperature 176 Deg F (80 Deg C) Closed Circulating Systems 140 Deg F (60 Deg C) Open Circulating Systems 176 Deg F (80 Deg C) Potable Water Circulating Systems Working Pressure 145 PSI (10 bar) Max Maximum Water Hardness 18.8 Grain (gr/US Gal) Minimum Inlet Pressure Top Z 1 ½” 104 Deg F (40 Deg C) 7.1 PSI 176 Deg F (80 Deg C) 11.4 PSI Top Z 2” & 3” 140 Deg F (40 Deg C) 11.4 PSI 176 Deg F (80 Deg C) 14.2 PSI Ambient Temperature Range 32 Deg F (0 Deg C) to 104 Deg F (40 Deg C) Materials of Construction Volute – Bronze (CuSi Alloy – Lead Free) Impeller – PPS, 40% Glass Filled (similar to Stratos) Shaft – Stainless Steel (X99 CrMo17-1) Bearings – Carbon (synthetic resin impregnated)

Top Z Available Single Phase Models Note: Curves different from Top S! All Single Phase Models Available 115 or 230 / 1 / 60 Volt (Curves Shown @ maximum Speed)

Top Z Available Three Phase Models Note: Curves different from Top S! All Three Phase Models Available 208/230, 460, 575 / 3 / 60 Volt (Curves Shown @ Maximum Speed)

Features and Benefits TOP Z Wet Rotor Technology The Silent One!! Noticeable sound - level for the human ear IPL 40-140 60 dB 20 dB (A) less means only less than 10% of noise !! Top S 40 dB

Top Z Sound Level From 43 to 48 db! Super Silent Top Z Wet Rotor Pumps db(A) 130 120 110 100 90 80 70 60 50 40 30 20 10 Office Truck Rock Concert Siren Jack Hammer Trees Factory Noise Traffic Conversation Sound Room Aircraft Noise Top Z Sound Level From 43 to 48 db!

Top Z Filling and Venting Rotor Can Fills: p system> p cartridge Filling Complete: p system= p cartridge T system 1 P system P Pressure in Rotor/Can Assy T Temp Rotor/Can Fluid. 2

Top Z - 1 ½” Filling and Venting Type 1 Filling process cartridge option 1: The fluid runs throught the check valve (the valve opens at 0-7.2 psi) into the internal shaft hole and escapes via the shaft cross-hole in front of the outboard bearing into the outboard rotor area. The rotor area is filled. The fluid runs through the grooved outboard bearing (4 longitudinal grooves at the outside diameter) into the outboard bearing area and on the other side via a gap between rotor and rotor can to the inboard bearing. The air escapes via the longitudinal grooves of the radial bearings and the gap between the rotor and the rotor can to the upper 1/3 of the inboard and accumulates there (approx. 30-40% air volume). Note the inboard bearing is still water lubricated as it remains 2/3 submerged. The valve closes when there is a pressure balance between the system and the rotor/can pressures.

Top Z - 2” & 3” Filling and Venting Type 2 Filling process cartridge option 2: The fluid runs throught the check valve (the valve opens at 0-7.2 psi) into the internal shaft hole and escapes via the shaft cross-hole in front of the outboard bearing into the outboard rotor area. The rotor area is filled. The fluid runs through the grooved outboard bearing (8 longitudinal grooves at the outside diameter) into the outboard bearing area and on the other side via a gap between rotor and rotor can to the inboard bearing. The air escapes via the longitudinal grooves of the radial bearings and the gap between the rotor and the rotor can to the upper 1/3 of the inboard and accumulates there (approx. 30-40% air volume). Note the inboard bearing is still water lubricated as it remains 2/3 submerged. The valve closes when there is a pressure balance between the system and the rotor/can pressures.

Top Z Filling and Venting mechanical seal venting operation: Psystem.< Pcartridge popen phydr. pcartridge Tmed. 1 Tmed. 2 check valve bearing bracket popen check valve= 0 -7.2 psi

Top Z Filling and Venting The pump rotor chamber will vent automatically with sytem pressure. The TOP-Z models (TOP-Z 1.5x15 and TOP-Z 1.5x20) equipped with a vent screw can be manually vented (see I/O manual). Venting during operation: During the pump operation the temperature inside the rotor area increases by heat caused by the motor, consequently the internal pressure in the cartridge increases as well. This causes a pressure difference between interior and exterior (p system > p cartridge). At a pressure difference of 21.8 psi the mechanical seal opens and the the fluid (including air) escapes via the front bearing slots at the bearing bracket. This venting operation may cause a low pressure in the rotor area. The check valve opens at the pressure difference of 0-7.2 psi and the fluid enters the rotor area until the pressure is balanced.

Top Z Filling and Venting The TOP-Z is automatically vented, as is all WILO wet rotor pumps. Due to the design of the rotating assembly and operating conditions this operation may take some time. The process can be accelerated by the following measures. Ventilation of rotor area via air-vent screw (TOP-Z 1.5x15 and TOP-Z 1.5x20). For details see installation and operating instructions, chapter „Filling and venting“. Switching the pump on an off several times. Provide longer breaks between switching on and off so that the many small air bubbles in the rotor area can accumulate to one air bubble. Due to the pressure compensation the air escapes better. Close the shut-off valve on the pressure side of the pump abruptly during pump operation. This causes the internal pressure on the suction side of the impeller to increase so that the valve opens (p system > p cartridge) and the fluid enters the rotor area. Due to the pressure increase in the rotor area the accumulated air is pressed out via the mechanical seal. Then the valve can be opened and the operation may be repeated until there are no more air noises in the pump.

Installation Instructions – Top Z Install with shaft horizontal Pump in any direction (vertical, horizontal etc.) If pumping vertical try to pump up (with air) Fluid should be relatively free of abrasive particles Damages sleeve bearings in wet runners and mechanical seals in dry runners Maximum water hardness 18.8 gr/USgal Install with terminal box @ 9:00, 12:00 or 3:00 positions Installing @ 6:00 can allow fluid into terminal box during air bleeding Be careful with the suction side (laminar flow)

Inside the Terminal Box – Top Z (Identical to the Top S) Single Phase Three Phase Speed Selector (all voltages) Green Power on Light Ground Screw L & N Power Inputs C1, C2 Pre-wired Capacitor Leads P1, P2 Overload Circuit (no load N/C contact) Speed Selector (all voltages) Green Power on Light Red Reverse Rotation (Off if OK) Ground Screw L1, L2 & L3 Power Inputs P1, P2 Overload Circuit (no load N/C contact)

Wiring Instructions – Top Z Sticker on the Inside of the Terminal Box Cover Single Phase Three Phase

Installation Instructions – Top Z Terminal Box and Shaft Orientation Direction of Flow & Condensate Drain

Application Types – Top Z Applications Only Bronze Models Available! Potable Water (Domestic Hot Water Recirculation Systems) DHW Boiler Pumps Primary and Secondary Hot and Chilled Water Systems Up to 50 % Maximum Glycol in Heating and Cooling Applications For indoor use only

Top Z Cross References

Top Z Cross References

Top Z Cross References

Top Z Cross References

Top Z - What’s the Difference (review)? Vs Top S No system fluid exchange Handles hard water Lead free NSF 61 Compliant DHW suitable impeller Flatter performance curves Same wiring etc as Top S Same model designation as Top S Curves designed for application Easier to cross reference Vs Competition Quieter Maintenance free 2 speed Min speed eliminates piping erosion Handles hard water better (no seal) Lead free NSF 61 Compliant DHW suitable impeller Flatter performance curves Fewer models to stock Higher flows Top Z - What’s the Difference – You be the Judge!

THANK YOU! Be sure to check the WILO NA web site (www.wilo-na.com) for additional training courses and the “Ask the Trainer” section! WILO Brain Box