GPHL Respirator Training

Slides:



Advertisements
Similar presentations
Standard 29 CFR Part Respiratory Protection.
Advertisements

Respiratory Protection from Airborne Infectious Agents
Respiratory Protection from Airborne Infectious Agents: Use of N-95 Disposable Particulate Respirators Vermont Department of Health, EMS Office This program.
Personal Protective Equipment (PPE)
Respiratory Protection – Half and Full Face Cartridge Respirators Training on the use of respirators in the workplace – module 2 Developed by the Division.
Respiratory Protection Training 29 CFR Respiratory Protection- Employer Roles Employers are required to: 1.Maintain a written respiratory protection.
OSHA’s Respiratory Protection Standard 29 CFR
Respiratory Protection HS 432 "Protective equipment … shall be provided, used, and maintained in a sanitary and reliable condition whenever it is necessary.
Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD /7110.
Respirator Awareness Training CFR
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
PPE Use in Healthcare Settings: How to Safely Don, Use, and Remove PPE
RESPIRATORY PROTECTION FROM AIRBORNE INFECTIOUS AGENTS
RAY W.HERRICK LABORATORIES SCHOOL OF MECHANICAL ENGINEERING F.E.Peacock Student Individual Learning Package Press ENTER KEY to change frame. DUST MASK.
ES&H Respiratory Protection. ES&H Respiratory Protection Overview Learning Objectives Hazard Communication Review Respiratory Protection Practice Elements.
Respiratory Protection
Use and Limitation of N-95 Filtering Facepiece Environment, Health and Safety Occupational Health and Hygiene 2009.
Introduction Respiratory protection is an essential element to protect employees from possible transmission of Tuberculosis and other infectious diseases.
RESPIRATORY PROTECTION / E N V I R O N H & S T R A I N I N G P R O G R A M RESPIRATORY PROTECTION The following program presents the respiratory requirements.
Unit 7.1. Respiratory protection TB Infection Control Training for Managers at National and Subnational Level Photo courtesy of WHO/Dominic Chavez.
OSHA’s Respiratory Protection Standard 29 CFR
Personal Protective Equipment Respirator Usage and Safety.
N95 Respirators: Use and Fit Testing Train the Trainer Presented by Connecticut OSHA in cooperation with DESPP/DEMHS and CT DPH.
Establishing a Respiratory Protection & Fit-Testing Program for FQHCs Amelia Muccio, Director of Disaster Planning, NJPCA.
Occupational Safety and Health Course for Healthcare Professionals.
Respiratory Protection – filtering facepieces (dust masks) Training on the use of respirators in the workplace Developed by the Division of Occupational.
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
Respiratory Protection Program 29 CFR Respiratory Protection Program When respiratory protection is necessary When respiratory protection is.
Safety Training Presentations
Respirator Training This training module is only for these type of respirators.
Personal Protective Equipment
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
RESPIRATORY PROTECTION STANDARD FEDERAL REGISTER 1/8/98 29 CFR Revised Other OSHA Standards That Incorporated By Reference.
Respiratory Protection
Respirator Regulations  NIOSH 42 CFR Part 84  OSHA 29 CFR
sss Employee Health sss
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
EHSRM (v. 1/04) 1 Environmental Health, Safety and Risk Management Bob Grieshaber Sue Kerns January, 2004.
Respiratory Protection
Respiratory Safety Public Safety Murray State University.
Guidance for the Selection and Use of Facemasks and Respirators Materials referenced from CDC, FDA, NIOSH and OSHA.
 Defines standard operating procedures to ensure the protection of all employees from respiratory hazards  Includes: ◦ Selection and Use ◦ Cleaning.
NIEHS – HMTRI Katrina Response Initiative 10/17/20052 U45 ES Safety Awareness for responders to Hurricane Katrina Operations: Respiratory Protection.
Penn State University Environmental Health and Safety Hazard Assessment and Personal Protective Equipment (PPE) Training.
National Fit Testing Services OSHA CFR Respiratory Protection Program Presented by National Fit Testing Services Linda Lane, RRT/President.
Respiratory Protection
Control of Airborne Respirable Dust Hazards: A Training Program for Underground Coal Miners The Penn State Miner Training Program University Park, PA
Respirator Training Filtering Facepiece Respirators (Dust Masks)
Washington University School of Medicine Medical Student N-95 Particulate Respirator Training.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
Respiratory Protection – Half and Full Face Cartridge Respirators Training on the use of respirators in the workplace – module 2 Developed by the Division.
Pandemic Influenza Planning
Respiratory Protection Program
Respiratory Protection from Airborne Infectious Agents:
Respiratory Protection Program
ESOHMS RESPIRATORY PROTECTION PROGRAM TRAINING
Respiratory Protection Training
ESOHMS RESPIRATORY PROTECTION PROGRAM TRAINING
Respiratory Protection Training
Ballast Dust on Worksites
Ensures compliance with OSHA 29 CFR
Click anywhere to get started…
Respiratory Protection Program
Concorp, Inc. - Respiratory Protection Training. Revision – B
OSHA’s Respiratory Protection Standard 29 CFR
Voluntary N-95 Respirator Use
OSHA’s Respiratory Protection Standard 29 CFR
Disaster Site Worker Safety
Disaster Site Worker Safety
Presentation transcript:

GPHL Respirator Training LaTonya Clay, Ph.D. Training Coordinator

Objectives Define respirator Discuss National Institute for Occupational Safety and Health (NIOSH) requirements Describe N95 and other respirator types Review respirator procedures Seal Check Donning/Doffing Describe storage requirements Discuss Medical Clearance and Fit Testing requirements

Respirators Personal protective device worn on the face that covers at least the nose and mouth Reduces the risk of inhaling hazardous airborne particles, including dust and infectious agents, gases, or vapors Considered the last line of defense in the occupational hierarchy of controls Recommended when engineering controls are not feasible or sufficient to control the hazard Protect the user either by filtering contaminated ambient air or by providing a clean source of air.

NIOSH National Institute for Occupational Safety and Health Federal agency responsible for conducting research and making recommendations to prevent workplace injuries and illnesses. Helps to assure safe and healthy working conditions National Personal Protective Technology Laboratory (NPPTL) is the division of NIOSH responsible for respirator certification. NIOSH-approved respirators are marked with the manufacturer’s name, the part number, the type of protection (for ex., N95) and the acronym, NIOSH.

N95 Respirator-NIOSH Requirements

N95 Respirators Used to protect against infectious aerosols produced when working with microorganisms, such as Rabies virus and Mycobacterium tuberculosis Do not provide protection from chemicals, gases or vapors. Other respirator types are required for protection against chemical vapors. The “N” designation indicates that the respirator is not resistant to oil. Other respirator types may begin with an “R” or “P” R95 respirators: Filter 95% of airborne particles and are somewhat resistant to oil P95 respirators: Filter 95% of airborne particles and are strongly resistant to oil

N95 Respirators Primary respirator type used at Georgia Public Health Laboratory Filter 95% of airborne particles that are 0.3 microns in size N95 Respirator Assigned Protection Factor (APF) = 10 An APF of 10 means that type of respirator (if used properly) can be safely used in an atmosphere that has a hazardous concentration of up to 10 times the Permissible Exposure Limit (PEL) for that hazard. Powered Air Purifying Respirators (PAPRs) APF= 1000 Provide a significantly higher level of protection as compared to disposable, tight-fitting N95 respirators

Surgical Masks Can not replace a NIOSH-approved respirator Only prevent the release of infectious aerosols from the individual, while N95 respirators filter aerosols prior to inhalation by the individual.

Respirator Donning and Doffing Don: to put on Doff: to remove or take off

General Donning Procedure When putting on a respirator (donning), complete the following: Ensure that the respirator is the same manufacturer, model, and size on which you were fit tested. Note: Review model and size information on your fit test form to ensure that it is consistent with your respirator. Review the appropriate manufacturer’s instructions specific to the respirator model in use to ensure that you are properly trained on donning the respirator. Inspect the respirator for damage prior to each use. Follow the manufacturer’s instructions for putting on the respirator and performing the seal check procedure.

Donning Procedure Example 3M 1860 Respirator Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand. Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose by pushing inward while moving your fingertips down both sides of the nosepiece. Perform a user Seal Check prior to each use.

Seal Check Procedure Example 3M 1860 Respirator Check the respirator-to-face seal by placing both hands completely over the respirator and exhaling slowly for ~10 seconds. Repeat above step and inhale for ~10 seconds instead of exhaling. Be careful not to disturb the position of the respirator. If air leaks around the nose, readjust the nosepiece as described in the third step of the 3M 1860 Donning Procedure. If air leaks around the respirator edges, work the straps back along the sides of your head. If you can not achieve a proper seal, try repeating this procedure with a new respirator. After additional attempts, do not enter the isolation or treatment area. Notify your supervisor.

Doffing Procedure Example 3M 1860 Respirator In order to remove an N95 respirator, complete the following steps: With gloved hands, cup the respirator in hand to maintain its position on face. Keep in mind that the contaminated area is across the front of the respirator. Pull the bottom strap over head. While holding the respirator in position, pull top strap over head and remove the respirator. Note: This procedure is specific to the 3M 1860 model of N95 respirators. Review and follow the manufacturer’s instructions for the respirator model in use in your area.

Other respirator types PAPR (Powered Air Purifying Respirator) is a loose-fitting respirator Use is required if employee has facial hair that interferes with the respirator-to-face seal Perform Seal and Damage Check prior to each use. PAPR is equipped with breathing tube, chargeable battery, filter and filter gasket that must be inspected prior to each use. Don/Doff, cleaning, maintenance, and storage must be performed according to manufacturer’s instructions. Reminder: Complete review of the PAPR powerpoint training.

Half-Face Respirator Type of protection depends upon cartridge type Charcoal cartridge protects against chemical vapors (Note: N95 respirators do not have this capability.) Establish a cleaning and storage schedule according to manufacturer’s instructions.

Respirator Storage Store in clean areas only—not in contaminated areas. Use plastic containers and/or ziploc bags to protect against... Contamination and dust Excessive temperatures and moisture Deformation Damage

Medical Clearance Prior to respirator fit testing OSHA requirement Employees with asthma are to use PAPRs or loose-fitting respirators instead of tight-fitting respirators Complete GPHL Proof of Medical Clearance Form Note: Medical clearance is at employee’s expense Indicate on the aforementioned form if you waive this clearance

Respirator Fit Testing Respirator training and fit testing are both required annually and before initial use of respirator Must be repeated if the user experiences significant changes in physical conditions, such as weight loss or gain, and surgery or injury to face

Respirator Assessment Access and complete the Respirator Exam: After you have reviewed the PAPR training powerpoint in SABA By closing the training window(s) and clicking on the Respirator Exam link Respirator Fit Testing is coordinated by GPHL Safety Officer. Fit Testing: Quantitative, On-Site -or- Qualitative, Off-Site Contact: LaTonya Clay, Ph.D. Email: laclay@dhr.state.ga.us