Monday 11th June 08:10 Beam dumped in the ramp by OP. OFB did not start its function and kept the injection orbit. 08:50 Switch LHCb polarity to negative.

Slides:



Advertisements
Similar presentations
21/05/2012LHC 8:30 meeting Overview Week 20 Injectors, LHCb polarity, Beam-Beam Coordinators: Bernhard Holzer, Jan Uythoven.
Advertisements

09:25 Operator dump fill #2178, integrated lumi 107/108/18 nb-1. Trip of RQ4.R6 (fire heaters discharged) just after the beam dump but the QPS gave no.
:30 meetingEBH 1  No beam during the morning:  4:15 – 9: V distributor: Recovery after electrical interruption  access for TI services.
Monday – Morning L. Drosdal: Injection line TI8: IQC threshold for BPM H from 2mm to 2.5mm to avoid unnecessary latches due to variations.
Wednesday
Wednesday :06 Dump fill 3533: interlock BPMS in IP6
Friday 15th June 01:11 Injection.
Monday :00 Stable beams 9_6_6_6 13:40 Access.
Monday fill with 1092 bunches (6 h stable beams)
Saturday 30th June - Sunday: Rocky !
Thursday 09:30 VdM scan for CMS, standard ADT gain.
Summary week 23 Luminosity production
02/08/ :35: Lost access chain in point 2 (PX24 PAD)  Dump after ~14.5 hours ~100 nb-1.
Tue :25 Beams dumped due to RF vacuum interlock
LHC Morning Meeting - G. Arduini
Saturday 12:00 Fill 1992 in stable beams.
Monday 6th August & night
Fri 29/7 – Sat 30/7 09:00 End of fill 1990, PC trip RCBXV3.R1 (likely SEU on QPS). Integrated Luminosity: 41 pb-1. Access for MKI2 main switch replacement.
Fri 15th – Sun 16th June Friday Saturday Sunday Monday
Summary of week 22 Machine Coordinators: G. Arduini, M. Lamont Main aim: Luminosity production.
Tuesday 08:30 Fill 2700 dumped by QPS on RCBXH2.L1
Thursday 17th May 01:11 Fill #2633 dump in squeeze arc circulator load channel Ad1B 03:16 Fill #2644 Stable beams, lumi 5.2e33 cm-2s-1 04:38 Dumped by.
Wednesday 31 October: Morning
Friday 31st August & night
Friday day 00:51 Fill #1862 Beams lost to inner triplet skew quad power converter fault. Delivered lumi 33 pb-1 Access required for repair RQSX3.L1 converter.
Mike Lamont, Jorg Wenninger
LHC Morning Meeting - G. Arduini
Friday Morning 3:44 – 15:04 stable beams Fill (dumped by operator)
LHC Operations overview Week 28 – Getting back
Monday Morning – recovery from cryo.
Chromaticity can make a difference…
04-05/08/2010 End of physics at ~11:00 after 18.5 hours ~120 nb-1.
Friday morning 10:30 Optics measurements and corrections.
Thursday :00: Physics fill from the night shift
Wire almost entirely through beam before BLM triggers dump
Friday Morning 7:30 injection for fill 2908
Friday AM Some oscillations of the cryo conditions in MSR8 perturbed the setup for injection. RF frequency interlock fixed – required a reset of RF controls.
Sunday/Monday & :30 Stable beams. Fill #1851.
Aims for the week Recover from technical stop and precycle at 10A/s
Thursday Physics fill 1250 (with 13b) dumped at 10.30
LHC Morning Meeting - G. Arduini
Rocky last 24 hours Losses Q6.R5 Orbit SIS TCDQ OK! Power converters
LHC Morning Meeting - G. Arduini
Tue/Wed 12/ :00 Probe beam back again
Thursday 26th July 13:21 Fill 2880 beam dumped
Thursday – Morning Energy matching at injection with H CODs
Monday 6th 07:39 Dump fill #1854, RQ6.L2 tripped, followed by access
Friday 8/10/10 - Morning Planned to keep fill until the afternoon
Monday morning 09:40 Dump fill 2838, integrated ~130 pb-1.
Thursday 22 September 2011.
Friday 14th September 03:15 Beta* at 1 km. Optics measurements, see yesterday. 07:00 Dump. 08:00 Refill with 3 nominal bunches for high beta. 11:15 Beams.
Saturday :42 stable beams fill 3541
Polarity inversion 07:00 ALICE solenoid and dipole polarity switched to positive External Crossing angle polarity unchanged at injection/ramp & squeeze.
Friday morning 08:00 Stable beams with 840b.
LHC Morning Meeting - G. Arduini
Thu 04:00 Fill #2729 Stable Beams. Initial lumi 6.5e33 cm-2 s-1.
Saturday 06/11 Triplet R8 tripped during ramp for collision setup.
Coordination: Eva Barbara Holzer, Mike Lamont
Monday 26th September 7:30 Beam dump, QSP on RQX.R1, lost cryo in ITR1, 91 pb-1. Cryo recovery, needed about 1.5 h. Setting of TI2 collimators to 5 sigma.
LHC Morning Meeting - G. Arduini
Monday 27th August & night
Wednesday 26 October 2011.
Wednesday morning / afternoon
Wednesday morning Waiting for PS – problem on RF cavity.
Monday 14th May 00:03UFO at BLMQI.06R8.B2E10_MQML. Beam dump Re-steering required for TI2 03:28 STABLE BEAMS # e11 ppb, 4.11e33 cm-2s-1 13:36.
Wed 12/10 09:30 – 10:30 Ramp down of ALICE solenoid to 50% nominal field on request of ALICE. Increase of the vacuum (e-cloud in this area that has not.
Saturday 26 November 2011.
Tuesday
Thursday 10:00 Fill 1986 in stable beams.
Presentation transcript:

Monday 11th June 08:10 Beam dumped in the ramp by OP. OFB did not start its function and kept the injection orbit. 08:50 Switch LHCb polarity to negative 09:28 Change of RBAC rules for OFSU and test afterwards. 10:51 Start test ramp with 24 bunches - Optimised IP1 collision values incorporated 14:34 Fill #2743 Stable Beams. 17:01 Dump due to trip of ROD.A81B1 (RR13) , followed by ROF.A81B1 and RSF1.A81B1, looks like a SEU. Int. lumi around 46 pb-1. 20:03 Fill #2724 Stable Beams 21:17 Dump due to electrical perturbation, triggered first FMCM on RD1.LR1 and heaters discharge on RQ10.R4. Int. lumi around 26 pb-1. Waiting for quench heater to cool down -  access for ALICE. 23:55 Access and pre-cycle finished 00:30 to 02:12 CMS electrical problem – access – could not fix 02:54 injecting for physics – dumped, access system wrong manipulation Patrol and pre-cycle 05:18 No beam from injectors – PS RF beam controller problem 08:00 Probe beam back again…. 12/05/2012 LHC 8:30 meeting

LHCb polarity change to negative Test ramp with 2 x 24 bunches Check head-on collisions for LHCb, ATLAS and CMS LHCb reproduced previous settings for negative polarity For V: (180 um + 6um) /2 - 100 um = 7 um. Will not change the function For H: (160um +37 um)/2 - 42 um = 58 um. Incorporated in IP8_SEPSCAN_X_MM ATLAS changes incorporated CMS no changes 12/05/2012 LHC 8:30 meeting

Fill #2723 Clean injection, BLM losses squeeze and adjust < 40 % Initial lumi’s OK No loss individual bunches 17:01 Dump due to trip of ROD.A81B1 (RR13) , followed by ROF.A81B1 and RSF1.A81B1, looks like an SEU. Integrated. lumi around 46 pb-1. 12/05/2012 LHC 8:30 meeting

No loss individual bunches 12/05/2012 LHC 8:30 meeting

SEU? The U_res of ROD.A81.B1jumps and saturates all of a sudden. 12/05/2012 LHC 8:30 meeting

Fill #2724 Filling not smooth due to various BQM interlocks in SPS (bunch length, bunch peak, satellites, pattern) Large spread bunch intensities Initial lumi’s a bit lower, only just above 6e33 cm-2s-1 21:17 Electrical perturbation triggered first FMCM on RD1.LR1 and heaters discharge on RQ10.R4 Dump resistor 3 at 150C for RB.45 12/05/2012 LHC 8:30 meeting

‘Special bunches’, some losses The B1-bunches which collide only in IP8 (0,2,4) experience a gentle loss increase at about 20:11, while the equivalent bunches of B2 (24, 26 and 28) don't show any change of their loss-slope 12/05/2012 LHC 8:30 meeting

Forcing a door at 03:02 in the morning… Fill #2725 Dumped during injection for physics Beam dump caused by a wrong manipulation of the access door. CSR forced the PAD in PM18 to add a missing "plombage" on the internal handle. This caused the loss of beams and of S12 and S81 as foreseen. Security guard team opened the PAD, using their key. Apparently there was a "plombage" missing on the inside of the PAD, and they wanted to repair it!!! They tell us that CSA told them he had called the CCC and it was ok to touch the PAD. We did not know anything about the intervention. Forcing a door at 03:02 in the morning… 12/05/2012 LHC 8:30 meeting

The Lists Done: Outstanding SPS Q20 extraction tests to TI2/8 downstream TED. Outstanding Impact of TETRA on hump / beam. 30 mins at injection with probe bunches. Access: CMS electrical problem Muon chambers ALICE access nQPS sector 78 (power cycle needed afterwards) TCLIB.6R2.B1 electronics and LVDT sensor. MAD PM15: motors of inner doors not working (at least 4 hours). RQTL11.R7B2 temp DFBAN spikes (~3 to 5 hours). BI in Pt4 (3-4 hours, working hours). MKA test in Pt4 (1-2 hours) in preparation for MD LBDS TSU surveillance check Pulse MKD/MKB in local in preparation for TS2 TOTEM vacuum gauge (3 hours). MCBV18.L4B1 and RCO.A12.B1 to be repaired. 12/05/2012 LHC 8:30 meeting