Structure delineation in the presence of metal – A comparative phantom study using single and dual-energy computed tomography with and without metal artefact.

Slides:



Advertisements
Similar presentations
Impact of moving target on measurement accuracy in 3D and 4D PET imaging—a phantom study  Yunfeng Cui, PhD, James Bowsher, PhD, Jing Cai, PhD, Fang-Fang.
Advertisements

Automatic treatment planning improves the clinical quality of head and neck cancer treatment plans  Christian Rønn Hansen, Anders Bertelsen, Irene Hazell,
M.A. Maraci, C.P. Bridge, R. Napolitano, A. Papageorghiou, J.A. Noble 
B. Rosario Campomanes-Álvarez, O. Ibáñez, F. Navarro, I. Alemán, M
Physics and Imaging in Radiation Oncology
Effect of variations in atelectasis on tumor displacement during radiation therapy for locally advanced lung cancer  Nathan Tennyson, MD, Elisabeth Weiss,
Vaginal Motion and Bladder and Rectal Volumes During Pelvic Intensity-Modulated Radiation Therapy After Hysterectomy  Anuja Jhingran, M.D., Mohammad Salehpour,
A multinational audit of small field output factors calculated by treatment planning systems used in radiotherapy  Wolfgang Lechner, Paulina Wesolowska,
Physics and Imaging in Radiation Oncology
Evaluation of diffusion weighted imaging for tumor delineation in head-and-neck radiotherapy by comparison with automatically segmented 18F-fluorodeoxyglucose.
2-[18F]fluoro-2-deoxy-d-galactose positron emission tomography guided functional treatment planning of stereotactic body radiotherapy of liver tumours 
Evaluation of localized region-based segmentation algorithms for CT-based delineation of organs at risk in radiotherapy  Mehdi Astaraki, Mara Severgnini,
2-[18F]fluoro-2-deoxy-d-galactose positron emission tomography guided functional treatment planning of stereotactic body radiotherapy of liver tumours 
Automatic treatment planning improves the clinical quality of head and neck cancer treatment plans  Christian Rønn Hansen, Anders Bertelsen, Irene Hazell,
Retrospective methods to estimate radiation dose at the site of breast cancer development after Hodgkin lymphoma radiotherapy  Nicola S. Russell, Inge.
Physics and Imaging in Radiation Oncology
Pancreatic tumor motion reduction by use of a custom abdominal corset
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology
Michiel van den Bosch, Michel Öllers, Bart Reymen, Wouter van Elmpt 
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology
Emma Hedin, Anna Bäck, Roumiana Chakarova 
VMAT radiation-induced nausea and vomiting in adjuvant breast cancer radiotherapy: The incidental effect of low-dose bath exposure  G. Lazzari, A. Terlizzi,
Physics and Imaging in Radiation Oncology
Resolution of atelectasis during radiochemotherapy of lung cancer with serious implications for further treatment. A case report  Lore Helene Braun, Stefan.
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology
Comparison of complexity metrics for multi-institutional evaluations of treatment plans in radiotherapy  Victor Hernandez, Jordi Saez, Marlies Pasler,
Technical Innovations and Patient Support in Radiation Oncology
Axillary radiotherapy for nodal lymphoma: What CTV expansion is required to account for absence of pre-chemotherapy treatment position FDG PET-CT?  Robin.
Physics and Imaging in Radiation Oncology
Precision and accuracy of computed tomography foot measurements
Advantages of intensity modulated proton therapy during hippocampal avoidance whole brain radiation therapy  Joshua Stoker, Sujay Vora, Ameet Patel, David.
Cone beam computed tomography-based monitoring and management of target and organ motion during external beam radiotherapy in cervical cancer  Nina Boje.
Simultaneous integrated prophylactic cranial irradiation in sino-nasal cancer  Kenneth Jensen, Maja Bendtsen Sharma, Simon Lenler-Eriksen, Per Friis, Anne.
Kiran Devisetty, MD, Joseph K. Salama, MD  Journal of Thoracic Oncology 
The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT: a preliminary phantom study on two different CT.
Physics and Imaging in Radiation Oncology
Characterizing geometrical accuracy in clinically optimised 7T and 3T magnetic resonance images for high-precision radiation treatment of brain tumours 
Physics and Imaging in Radiation Oncology
Combined morphologic and metabolic pipeline for Positron emission tomography/computed tomography based radiotherapy response evaluation in locally advanced.
On the conversion of dose to bone to dose to water in radiotherapy treatment planning systems  Nick Reynaert, Frederik Crop, Edmond Sterpin, Iwan Kawrakow,
Feasibility of stereotactic body radiotherapy for locally-advanced non-small cell lung cancer  Katrina Woodford, Vanessa Panettieri, Trieumy Tran Le,
Eline D. Hessen, Laurens D. van Buuren, Jasper A. Nijkamp, Kim C
Fast 4D cone-beam CT from 60 s acquisitions
Skin dose calculation during radiotherapy of head and neck cancer using deformable image registration of planning and mega-voltage computed tomography.
Radiotherapy for isolated granulocytic sarcoma: Case report and review of literature  Jose Antonio Dominguez Rullán, Eva Fernández Lizarbe, Belén Capuz,
Physics and Imaging in Radiation Oncology
Uncertainty evaluation of image-based tumour control probability models in radiotherapy of prostate cancer using a visual analytic tool  Oscar Casares-Magaz,
The posterior cerebellum, a new organ at risk?
Sites of recurrent disease and prognostic factors in SCLC patients treated with radiochemotherapy  Rebecca Bütof, Calogero Gumina, Chiara Valentini, Antje.
Design, fabrication, and validation of patient-specific electron tissue compensators for postmastectomy radiation therapy  Daniel F. Craft, Peter Balter,
Rectal volume variations and estimated rectal dose during 8 weeks of image-guided radical 3D conformal external beam radiotherapy for prostate cancer 
An in-silico quality assurance study of contouring target volumes in thoracic tumors within a cooperative group setting  Hesham Elhalawani, Baher Elgohari,
Cone beam CT based dose calculation in the thorax region
Prostate-specific membrane antigen positron emission tomography/computed tomography as a potential tool to assess and guide salivary gland irradiation 
Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer  Shyama U. Tetar, Anna M.E. Bruynzeel,
Peter de Boer, Stefano Mandija, Anita M
Clinical and Translational Radiation Oncology
The rationale for MR-only treatment planning for external radiotherapy
Surface doses of flattening filter free beams with volumetric modulated arc therapy dose delivery for breast cancer  Jan Seppälä, Aleksi Voutilainen,
R. Botman, S. U. Tetar, M. A. Palacios, B. J. Slotman, F. J
Beyond T2 and 3T: New MRI techniques for clinicians
Technical Innovations and Patient Support in Radiation Oncology
Probabilistic optimization of dose coverage in radiotherapy
Evaluation of plan adaptation strategies for stereotactic radiotherapy of lymph node oligometastases using online magnetic resonance image guidance  Dennis.
Physics and Imaging in Radiation Oncology
Volumetric and dosimetric comparison of two delineation guidelines for the radiation treatment of laryngeal squamous cell carcinoma  C. Bondue, S. Racadot,
Prospective quantitative quality assurance and deformation estimation of MRI-CT image registration in simulation of head and neck radiotherapy patients 
Presentation transcript:

Structure delineation in the presence of metal – A comparative phantom study using single and dual-energy computed tomography with and without metal artefact reduction  Erik Pettersson, Anna Bäck, Thomas Björk-Eriksson, Ulrika Lindencrona, Karin Petruson, Anne Thilander-Klang  Physics and Imaging in Radiation Oncology  Volume 9, Pages 43-49 (January 2019) DOI: 10.1016/j.phro.2019.01.001 Copyright © 2019 The Authors Terms and Conditions

Fig. 1 Left: A photograph of the phantom with the central cylinder containing five structures denoted 1 to 5 in homogeneous gelatine. Tissue surrogate inserts with six different mass densities, lung exhale (0.50 g/cm3), adipose (0.96 g/cm3), breast (0.99 g/cm3), plastic water (1.03 g/cm3), liver (1.07 g/cm3) and trabecular bone (1.16 g/cm3) were inserted in the six frontal and dorsal positions of the phantom. Ten cm of plastic water slabs were placed in both the cranial and caudal direction of the central electron density phantom during the CT scans. The caudal slabs are not present in the photograph. Right: A SECT image of the phantom acquired with PMMA inserts in the lateral positions (A10) with display window level and width set to 40 HU and 400 HU, respectively. The two PMMA cylinders are marked with asterisks (*). Physics and Imaging in Radiation Oncology 2019 9, 43-49DOI: (10.1016/j.phro.2019.01.001) Copyright © 2019 The Authors Terms and Conditions

Fig. 2 The central slice in each of the image series of phantom set-up A (A1-A13). The image series were ordered in a sequence of decreasing severity of metal artefacts. Image series number 13 does not depict the whole phantom as it was reconstructed with a reduced display field of view of 25 cm. The same sequence was used for both phantom set-ups. Physics and Imaging in Radiation Oncology 2019 9, 43-49DOI: (10.1016/j.phro.2019.01.001) Copyright © 2019 The Authors Terms and Conditions

Fig. 3 The contours delineated by the four radiation oncologists (green) and the reference contours (red) in the central image slice of each of the 13 image series in phantom set-up A. For each phantom set-up, image series 13 was also used to create the red reference contours. Only the central part of the phantom is displayed in the figure, but the oncologists were shown the whole images. For the corresponding figure with set-up B, see Fig. B.1 in the supplementary material. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.) Physics and Imaging in Radiation Oncology 2019 9, 43-49DOI: (10.1016/j.phro.2019.01.001) Copyright © 2019 The Authors Terms and Conditions

Fig. 4 Delineation of all structures (1–5) by all four radiation oncologists, for the 13 image series with the set-up A (a) and B (b). The numbering of the structures is given in the image in the top left corners. The colours in the cells indicate how many of the four radiation oncologists that delineated each structure in each image series (white = 0, red = 1, orange = 2, yellow = 3, green = 4). The minimum and maximum values of the corresponding Dice similarity coefficients and Hausdorff distances for each structure and image series, are given with the colour scheme described above for each phantom set-up. Reference denotes the SECT scans performed with the DECT scanner, these image series (A13 and B13) were used to create a reference structure sets. (For interpretation of the references to colour in this figure legend, the reader is referred to the web version of this article.) Physics and Imaging in Radiation Oncology 2019 9, 43-49DOI: (10.1016/j.phro.2019.01.001) Copyright © 2019 The Authors Terms and Conditions