Intra-Aortic Balloon Pumps

Slides:



Advertisements
Similar presentations
Intra-aortic Balloon Pump (IABP)
Advertisements

CO - RELATION WITH ECG INTRA CARDIAC PRESSURES ASHOK MADRAS MEDICAL MISSION CHENNAI
By: ABDULRAHMAN ALSALMI INTRA AORTIC BALLOON PUMP CHIEF CARDIAC PERFUSIONIST KFMMC.
Innovative Minimally Invasive Circulatory Assist Device.
Cardiogenic Shock and Hemodynamics. Outline Overview of shock – Hemodynamic Parameters – PA catheter, complications – Differentiating Types of Shock Cardiogenic.
The Cardiovascular System
Ventricular Assist Devices Brian Schwartz, CCP February 25, 2003.
2nd Edition / 2002 The information contained on the following pages, in conjunction with the slides provided at the back of this binder, complete the Introduction.
The Cardiac Cycle, Pump Function & Blood Pressure.
Intra-Aortic Balloon Pump Counterpulsation
The Circulatory System
Blood Pressure. Blood pressure is the force exerted by the blood against the walls of the blood vessels. It is necessary to maintain blood flow though.
Chapter 16 Assessment of Hemodynamic Pressures
Cardiovascular Anatomy and Physiology AFAMS Residency Orientation April 16, 2012 ARMED FORCES ACADEMY OF MEDICAL SCIENCES.
CIRCULATORY SYSTEM A&P 4 By Angie Lawson RN, BSN.
Cardiogenic Shock Dr. Belal Hijji, RN, PhD October 12 & 15, 2011.
ECMO AT THE U of M Two era’s 1974 & patients. Kolobow Membrane Lung – Roller Pump – Adult and Peds. Patients. No Survivors 1986 to present.
Copyright © 2008 Lippincott Williams & Wilkins. 1 Assessment of Cardiovascular Function Hemodynamic Monitoring.
Learning Objectives... To understand the stages of the cardiac cycle.
Intra-Aortic Balloon Pump What it is and what it does
Pre-ICU training. 工作態度 會客時主動告知病情 病歷每天書寫 2 次 主動反應問題 接觸病人前後洗手.
Mediastinum.
IABP- Instrumentation, Indications and Complications
The Heart. HEART Main organ that moves blood through the body Pumps around 5 L/minute On average, pumps 75 years continuous It is about the size of a.
Terapie chirurgiche dell’Insufficienza Cardiaca
Intra-aortic baloon pumps what, who, why why why? Daniel Lovric Fellow, CVICU Auckland City Hospital Auckland Region ICU Study Day 30th October 2014.
Pressure changes during the cardiac cycle. P N L Atrial systole Ventricle systole Diastole.
ClearWay™ RX Therapeutic Perfusion Catheter. ClearWay™ RX In Action Potential Advantages of ClearWay TM: Delivers drug at high concentration to site of.
CORONARY CIRCULATION.
Review for Cardiovascular Quiz. What is the Name of the following Structures?
Conflict of Interest Baxter Research Grant Medtronic Research Grant
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Manifestations of Cardiac Disease in Carotid Duplex.
Date of download: 7/10/2016 Copyright © The American College of Cardiology. All rights reserved. From: Echocardiography for Percutaneous Heart Pumps J.
IABP Review and Competency
Special circulations, Coronary, Pulmonary…
University of Chicago Medicine
ClearWay™ RX Therapeutic Perfusion Catheter
Fig. 1. Patient transferred to ICU with IABP inserted surgically through left axillary artery approached at deltoido-pectoralis groove (a). Correct position.
Chapter 9 Cardiovascular System.
Special circulations, Coronary, Pulmonary…
Open Repair of Distal Aortic Arch and Proximal Descending Thoracic Aortic Aneurysm Using a Stepwise Distal Anastomosis  Hitoshi Ogino, MD  Operative Techniques.
Intra-Aortic Balloon Pumps
Cardiovascular System
Reduction of systolic and diastolic dysfunction by retrograde coronary sinus perfusion during off-pump coronary surgery  Manuel Castellá, MD, Gerald D.
Enhanced computed tomography showing dissection-like features in an extracorporeal membrane oxygenation-supported patient with no cardiac output: Can.
Insights into the mechanism(s) of von Willebrand factor degradation during mechanical circulatory support  Carlo R. Bartoli, MD, PhD, Sujith Dassanayaka,
Endovascular techniques for arch vessel reconstruction
Mink Dissection Review
Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms  Michael L. Marin, MD, Richard E. Parsons,
Nat. Rev. Cardiol. doi: /nrcardio
Feasibility of profound hypothermia as part of extracorporeal life support in a pig model  Christoph Weiser, MD, Wolfgang Weihs, DVM, Michael Holzer, MD,
Pressure Wave Reflection at the Heart
Osamu Kawaguchi, MD, Walter E. Pae, MD, FACS, Bill B
The Heart and Circulation
Operation for Type B Aortic Dissection Using Hypothermic Selective Cerebral Perfusion  Keiichiro Tayama, MD, Hidetoshi Akashi, MD, Shuji Fukunaga, MD,
Beginning of percutaneous coronary interventions: Zurich 1976–1977
Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study  Yoshiyuki Takami, MD, Hiroshi.
Cardiovascular Transport
Organ perfusion with hemopump device assistance with and without intraaortic balloon pumping  Bart Meyns, MD, Yousuke Nishimura, MD, Rozalia Racz, MD,
Noritake Akaba, M. D. , Hisashi Ujiie, M. D. , Kazumasa Umezawa, M. D
Charles T. Klodell, MD, Philip J. Hess, MD, Thomas M
The Heart and Blood Pressure
The heart’s physiology
Surabhi Madhwal et al. JIMG 2014;7:
Transbrachial arterial insertion of aortic occlusion balloon catheter in patients with shock from ruptured abdominal aortic aneurysm  Hitoshi Matsuda,
Francesco Santini, Alessandro Mazzucco  The Annals of Thoracic Surgery 
Ascending versus descending aortic balloon
Introduction; The Cardiovascular System (CVS)
Hybrid Repair of an Aortic Arch Aneurysm Using Double Parallel Grafts Perfused by Retrograde Flow in Endovascular Repair Combined With Left Subclavian.
Presentation transcript:

Intra-Aortic Balloon Pumps

Intra-Aortic Balloon Pumps Purpose The intra-aortic balloon pump consists of a long inflatable balloon 26-28cm in length surrounding the distal end of a centrally placed catheter. It is used in the setting of cardiogenic shock to enhance cardiac function.

Intra-Aortic Balloon Pumps Access and Placement The balloon pump is introduced via the femoral artery and advanced retrograde into the thoracic aorta. The balloon is ideally situated with the tip located just distal to the left subclavian artery at the level of the aortic arch. Such placement ensures maximal augmentation of diastolic pressures in the proximal aorta. Inflation of the balloon during diastole increases diastolic pressure, enhancing perfusion of the coronary arteries and oxygen delivery to the myocardium. Deflation of the balloon during systole creates a vacuum within the vessel lumen, decreasing ventricular afterload and enhancing forward blood flow. The following radiograph demonstrates an IABP in the proper position.

Click to locate the SGC.

Click to locate the IABP tip. SGC Click to locate the IABP tip.

Click to locate the IABP proper. Tip of IABP SGC Click to locate the IABP proper.

Tip of IABP SGC IABP Click to proceed.