Quantitative Proteomics II: Targeted Quantitation

Slides:



Advertisements
Similar presentations
Instrumental Analysis
Advertisements

Protein Quantitation II: Multiple Reaction Monitoring
Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
Quantification of low-abundance proteins in complexes and in total cell lysates by mass spectrometry Bastienne Jaccard and Manfredo Quadroni Université.
Proteomics Informatics – Protein identification II: search engines and protein sequence databases (Week 5)
Proteomics Informatics Workshop Part I: Protein Identification
Previous Lecture: Regression and Correlation
Proteomics Informatics (BMSC-GA 4437) Course Director David Fenyö Contact information
Proteomics Informatics (BMSC-GA 4437) Course Director David Fenyö Contact information
Proteomics Informatics Workshop Part III: Protein Quantitation
Fa 05CSE182 CSE182-L9 Mass Spectrometry Quantitation and other applications.
Proteome.
Proteomics Informatics – Data Analysis and Visualization (Week 13)
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Organic Mass Spectrometry
Proteomics and Biomarker Discovery “Research-grade” Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, “How I learned to ditch.
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Analysis of Complex Proteomic Datasets Using Scaffold Free Scaffold Viewer can be downloaded at:
Metabolomics Metabolome Reflects the State of the Cell, Organ or Organism Change in the metabolome is a direct consequence of protein activity changes.
Quantification of Membrane and Membrane- Bound Proteins in Normal and Malignant Breast Cancer Cells Isolated from the Same Patient with Primary Breast.
June 9th, 2013 Matthew J. Rardin June 9th, 2013 Matthew J. Rardin MS1 and MS2 crosstalk in label free quantitation of mass spectrometry data independent.
Innovative Paths to Better Medicines Design Considerations in Molecular Biomarker Discovery Studies Doris Damian and Robert McBurney June 6, 2007.
Multiple flavors of mass analyzers Single MS (peptide fingerprinting): Identifies m/z of peptide only Peptide id’d by comparison to database, of predicted.
Isotope Labeled Internal Standards in Skyline
Proteomics Informatics (BMSC-GA 4437) Instructor David Fenyö Contact information
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Deducing protein composition from complex protein preparations by MALDI without peptide separation.. TP #419 Kenneth C. Parker SimulTof Corporation, Sudbury,
Proteomics Informatics (BMSC-GA 4437) Course Directors David Fenyö Kelly Ruggles Beatrix Ueberheide Contact information
Workflows to set up acquisition methods for scheduled sMRM-HR on the TripleTOF 5600 Start from a data dependent acquisition (DDA) Perform data base search.
What is proteomics? Richard Mbasu and Ben Richards.
DIA Method Design, Data Acquisition, and Assessment
Protein quantitation I: Overview (Week 5). Fractionation Digestion LC-MS Lysis MS Sample i Protein j Peptide k Proteomic Bioinformatics – Quantitation.
Introduction to Liquid Phase Mass Spectrometry
김지형. Introduction precursor peptides are dynamically selected for fragmentation with exclusion to prevent repetitive acquisition of MS/MS spectra.
Quantitation using Pseudo-Isobaric Tags (QuPIT) and Quantitation using Pseudo-isobaric Amino acids in Cell culture (QuPAC) Parimal Samir Andrew J. Link.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
Agenda  Welcome from the Skyline team!  Targeted Method Design  Introduction with Brendan MacLean  Tutorial with Brendan MacLean  Targeted proteomics.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
DIGE (difference gel electrophoresis)
Mass Spectrometry makes it possible to measure protein/peptide masses (actually mass/charge ratio) with great accuracy Major uses Protein and peptide identification.
Tandem MS.
Large Scale DIA With Skyline
Jarrett Egertson, Ph.D. MacCoss Lab
Bottom-Up Proteomics Data collection
Multiple Reaction Monitoring (MRM) Selected Reaction Monitoring (SRM)
The Syllabus. The Syllabus Safety First !!! Students will not be allowed into the lab without proper attire. Proper attire is designed for your protection.
MassMatrix Search Results Explained
View  text zoom  large Set properties text size to 14 point
Agenda Welcome from the Skyline team!
Volume 4, Issue 6, Pages e4 (June 2017)
Mass Spectrometry Vs. Immunoassay
Pinpointing phosphorylation sites using Selected Reaction Monitoring and Skyline Christina Ludwig group of Ruedi Aebersold, ETH Zürich.
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Protein/Peptide Quantification
Mass spectrometry-based proteomics
Bioinformatics Solutions Inc.
Chapter 1: The Nature of Analytical Chemistry
Proteomics Informatics David Fenyő
Proteomic Approaches to Cancer Biomarkers
Metabolomics: Preanalytical Variables
A perspective on proteomics in cell biology
Volume 4, Issue 6, Pages e4 (June 2017)
Proteomics Informatics –
NoDupe algorithm to detect and group similar mass spectra.
Volume 24, Issue 13, Pages (July 2014)
Shotgun Proteomics in Neuroscience
Proteomics Informatics David Fenyő
Kuen-Pin Wu Institute of Information Science Academia Sinica
Presentation transcript:

Quantitative Proteomics II: Targeted Quantitation

Traditional Affinity-based proteomics Using antibodies to quantify proteins RPPA Western Blot Immunohistochemistry ELISA Immunofluorescence

Using MS/MS for quantitative protein assays Most clinical and biology studies in the literature rely on measurement of proteins which already have antibodies available Goal of targeted proteomics is to create reliable, high quality assays to measure proteins that do not require antibodies and instead rely on MS/MS

Targeted Proteomics Focuses on a subset of proteins of interest Disease related changes in proteins Signaling processes Highly multiplexed alternative method to western blots/antibodies Can focus on unique and informative peptides for protein of interest Hypothesis driven questions! Nature Method of the Year 2012

Targeted Proteomics Overview

When to use targeted MS vs. global shotgun MS? Identify maximum number of proteins in limited number of conditions Identify limited number of proteins in maximum number of conditions r2=0.4698 RNA Protein Kennedy JJ et al., (2014) Nature Methods 11(2)

Mass Spectrometry based proteomic quantitation Shotgun proteomics LC-MS Targeted MS 1. Records M/Z 1. Select precursor ion MS MS Digestion 2. Selects peptides based on abundance and fragments Fractionation 2. Precursor fragmentation MS/MS MS/MS Lysis 3. Protein database search for peptide identification 3. Use Precursor-Fragment pairs for identification Data Dependent Acquisition (DDA) Uses predefined set of peptides

Multiple Reaction Monitoring (MRM) Triple Quadrupole acts as ion filters Precursor selected in first mass analyzer (Q1) Fragmented by collision activated dissociation (Q2) One or several of the fragments are specifically measured in the second mass analyzer (Q3)

MRM Instrumentation: Triple Quadrupole (QqQ)

Fragment Ion Detection

Peptide Identification with MRM Mass Select Fragment Ion Mass Select Precursor Fragment Q1 Q2 Q3 Transition Transition: Precursor-Fragment ion pair are used for protein identification Select both Q1 and Q3 prior to run Pick Q3 fragment ions based on discovery experiments, spectral libraries Q1 doubly or triply charged peptides Use the 3 most intense transitions for quantitation

Peptide Identification with MRM Used for to analyze small molecules since the late 1970s More recently, used for proteins and peptide quantitation in complex biological matrices Particularly for biomarker discovery With small molecules, the matrix and analyte have different chemical natures so separation step is able to remove other components from analytes Separation MS analysis With proteomics, both the analytes and the background matrix are made up of peptides, so this separation cannot occur Separation MS analysis

Strengths of MRM Can detect multiple transitions on the order of 10msec per transition Can analyze many peptides (100s) per assay and the monitoring of many transitions per peptide High sensitivity High reproducibility Detects low level analytes even in complex matrix Golden standard for quantitation!

Weaknesses of MRM Focuses on defined set of peptide candidates Need to know charge state, retention time and relative product ion intensities before experimentation Physical limit to the number of transitions that can be measured at once Can get around this by using time-scheduled MRM, monitor transitions for a peptide in small window near retention time

Parallel Reaction Monitoring (PRM) Q3 is substituted with a high resolution mass analyzer to detect all target product ions Generates high resolution, full scan MS/MS data All transitions can be used to confirm peptide ID Don’t have to choose ions beforehand Peterson et al., 2012

PRM Instrumentation: Quadrupole Time of Flight (Qqtof) The third quadrupole is replaced with a time of flight (TOF) mass analyzer offering high sensitivity, mass resolution and mass accuracy for both precursor and product ion spectra

Applications of MRM/PRM Metabolic pathway analysis Protein complex subunit stoichiometry Phosphorylation Modifications within protein Biomarkers: protein indicator correlating to a disease state Can enrich for proteins/peptides using antibody

Motivating example: AKT and breast cancer

MRM Workflow Clinical/Biological Question Proteotypic Define protein set Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Clinical/Biological Question Proteotypic LC and MS properties Intensity of transitions MS Interferences

MRM Workflow Clinical/Biological Question Proteotypic Define protein set Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Clinical/Biological Question Proteotypic LC and MS properties Intensity of transitions MS Interferences

Define the set of proteins based on a biological question

MRM Workflow Clinical/Biological Question Proteotypic Define protein set Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Clinical/Biological Question Proteotypic LC and MS properties Intensity of transitions MS Interferences

Selecting Peptides A few representative peptides will be used to quantify each protein Need to fulfill certain characteristics Have an unique sequence Consistently observed by LC-MS methods 8-25 amino acids Good ionization efficiency m/z within the range of the instrument No missed cleavages Not too hydrophillic (poorly retained) or hydrophobic (may stick to column)

Identifying Proteotypic Peptides Step 1: Full protein sequence in FASTA format Set of Proteins Trypsin Peptides Step 2: Tryptic Peptides PTPIQLNPAPDGSAVNGTSSAETNLEALQK LEAFLTQK PSNIVLVNSR LEELELDEQQR DDDFEK….. RefSeq Ensembl Uniprot Step 3: Compare to human reference database Proteotypic Peptides -Contain all peptide sequences -Find all peptides that only map back to one gene PTPIQLNPAPDGSAVNGTSSAETNLEALQK LEAFLTQK PSNIVLVNSR LEELELDEQQR DDDFEK….. Match peptide to proteins Match proteins to genes (Reference Protein DB) (Using protein names and genomic DB)

LC/MS Properties: GPMDB -Compares peptides to a collection of previously observed results -Determines how many times the peptide has been observed by others -Most proteins show very reproducible peptide patterns

LC/MS Properties: Skyline -Compares peptides to MS/MS spectral library -Predicts most abundant transitions

Selection of transitions MRM Workflow Define protein set Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Clinical/Biological Question Proteotypic LC and MS properties Intensity of transitions MS Interferences

Selecting Transitions Limitation of MRM-MS: ~1-2 m/z unit window for precursor and fragment ion occasionally let in interfering peptides with similar characteristics If we want to use these transitions for quantitation, we need to be confident there are no interferences Largest always largest, smallest always smallest etc. b-fragments of high m/z are less represented on QqQ MRM

Selecting Transitions Limitation of MRM-MS: ~1-2 m/z unit window for precursor and fragment ion occasionally let in interfering peptides with similar characteristics If we want to use these transitions for quantitation, we need to be confident there are no interferences Largest always largest, smallest always smallest etc. b-fragments of high m/z are less represented on QqQ MRM Peptide of interest Interfering peptide

Selecting Transitions: Skyline Can use to find best transitions to pick Intensity (rank) Dot product (similarity to reference spectra) Want high rank and dotp close to 1

Validation of transitions MRM Workflow Define protein set Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Clinical/Biological Question Proteotypic LC and MS properties Intensity of transitions MS Interferences

Validating Transitions: “Branching ratio” Branching Ratio (BR): ratio of the peak intensities 𝐵𝑅=𝑙𝑛 𝐼 𝐴𝑥 𝐼 𝐵𝑥 𝐼 𝐴𝑥𝑆 𝐼 𝐵𝑥𝑆 𝑛 Light (Analyte) Heavy(SIS) I1 I3 I1 I2 I2 I3 IAx, IBx : Peak areas of Analyte IAxS, IBxS : Peak areas of SIS n=number of SIS transitions Kushnir, 2005

Validating Transitions: AuDIT AuDIT: Automated Detection of Inaccurate and imprecise Transitions Uses “branching ratio” 1. Calculate relative ratios of each transition from the same precursor 2. Apply t-test to determine if relative ratios of analyte are different from relative ratios of SIS http://www.broadinstitute.org/cancer/software/genepattern/modules/AuDIT.html.

Validating Transitions: AuDIT Blue: Light Red: Heavy Relative product ions should have a constant relationship Abbatiello, 2009

PRM Workflow MRM PRM MS Target Selection Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Target Selection Selection of peptides Selection of transitions Selection/ Validation of transitions Protein Quantitation MS

PRM Workflow MRM PRM MS Target Selection Selection of peptides Selection of transitions Validation of transitions Protein Quantitation Target Selection Selection of peptides Selection of transitions Selection/ Validation of transitions Protein Quantitation MS

Protein Quantitation

Label-free quantitation Usually use 3 or more precursor-product ion pairs (transitions) for quantitation Relies on direct evaluation of MS signal intensities of naturally occurring peptides in a sample. Simple and straightforward Low precision Several peptides for each protein should be quantified to avoid false quantitation

Stable Isotope Dilution (SID) Use isotopically labeled reference protein 13C and/or 15N labeled peptide analogs Chemically identical to the target peptide but with mass difference Add known quantity of heavy standard Compare signals for the light to the heavy reference to determine for precise quantification Lysis Fractionation Digestion Synthetic Peptides (Heavy) Light LC-MS MS H L

Quantitation Details MS H L SIS: Stable Isotope Standard PAR: Peak Area Ratio Analyte SIS PAR = Light (Analyte) Peak Area Heavy (SIS) Peak Area Analyte concentration= PAR*SIS peptide concentration -Use at least 3 transitions -Have to make sure these transitions do not have interferences

Limit of Blank, Limit of Detection and Limit of Quantitation Limit of Blank (LoB) Highest analyte concentration expected to be found when replicates of a blank sample containing no analyte are tested Limit of Detection (LoD) Minimal quantity of an analyte that can be confidently detected Intrinsic to method or instrument Limit of Quantitation (LoQ) Minimal amount of an analyte that can be confidently quantified Signal LOQ LOD Noise

Calculating LOD, LOB and LOQ Limit of Blank (LoB) 9thth percentile of blank measurements Limit of Detection (LoD) Mean of blanks + 3*SD of blanks Limit of Quantitation (LoQ) Mean of blank + 10*SD of blanks 3*LOD Lowest concentration of peptide at which CV<20% Armbruster DA and T Pry. Clin Biochem Rev. (2008)

Standard Curve Standard concentration curve is generated using increasing concentrations of the “heavy peptide” in the presence of a constant amount of biological sample (aka matrix) Matrix contains the “light” version of the peptide Standard Curve typically created using: 5 heavy peptide serial dilutions Blank (no heavy) Once the curve is generated, biological samples can be processed measuring the amount of endogenous “light” peptide in each sample Using the calibration curve, we can compute the endogenous concentration from the ratio of endogenous/heavy (PAR)

Label Free: Standard Curve Lysis & Fractionation Digestion LC-MS MS

Lower Limit of Detection The lowest amount of analyte that is statistically distinguishable from background or a negative control. Two methods to determine lower limit of detection: Lowest concentration of the analyte where CV is less than for example 20%. Determine level of blank by taking 95th percentile of the blank measurements and add a constant times the standard deviation of the lowest concentration. K. Linnet and M. Kondratovich, Partly Nonparametric Approach for Determining the Limit of Detection, Clinical Chemistry 50 (2004) 732–740.

Limit of Detection and Linearity Measured Concentration Measured Concentration Theoretical Concentration Theoretical Concentration

Precision and Accuracy Measured Concentration Measured Concentration Theoretical Concentration Theoretical Concentration

Open Source MRM analysis tools

Data Independent Acquisition

SWATH-MS “Targeted” style method but allows for data collection on all precursor ions and not just a subset Spectra are acquired over entire mass range in small windows of defined size Data acquired on quadrupole-quadrupole TOF high resolution instrument cycling S.I. Anjo et al., Proteomics (2017)

SWATH-MS: Data Analysis MS co-fragments all peptide ions in a “swathe” Records fragment ions in high resolution mass spectrum Fragment ion intensities are extracted from the multiplexed spectra in a targeted way Create extracted ion chromatogram peak groups Rost et al, Proteomics (2017)

SWATH-MS: Data Analysis Skyline: Windows application for DDA and DIA MS methods Proteowizard: Converts vendor data into open formats Assay Libraries: library of transitions and retention times OpenMS: open source analysis package for large-sale datasets pyProphet: calculates FDR using target decoy DB TRIC Alignment: integrates information from multiple OpenSWATH runs and does cross-run and retention time correction Rost et al, Proteomics (2017)

Summary Targeted proteomics can be used as an alternative to antibody-based protein assays in hypothesis driven biological experiments. Allows for multiplexed analysis of many proteins in different conditions. PRM removes the step of transition validation and allows for all computational analysis post-acquisition. SWATH removes the step of peptide selection and generates transitions for all precursor ions in the defined precursor retention time and m/z Transition interference must be appropriately identified prior to protein quantitation. Several computational tools to predict and identify interferences in MRM and PRM have been developed.

Questions?