Introduction to the NGC Chromatographic System

Slides:



Advertisements
Similar presentations
Single-use Quantasep Systems First Bench-top Single-Use flow- path Chrom System with gradient capability.
Advertisements

1 The YL9100S HPLC All your needs for semi-preparative applications.
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
For Large Scale Purification
Total HVAC Control from anywhere Easy control that can save a fortune
Protein purification in practice Quantification of the procedure –How well did it work? –Did something go wrong? Where? Know how much fumarase is present.
Valve Washes LEAP Technologies. VSWII vs Active Wash LEAP VSW II CTC Active Wash System Number of solvent 42 Pumping system Syringe pump Solenoid Pump.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Lecture 9 Yuri Kazakevich Seton Hall University
Christian Gotenfels.
Introducing the EASY-nLC™
All you need to know – in the available time!
1 isr Institute for Sustainable Resources CRICOS No J Automated Greenhouse Gas Measurement System.
Introduction to the HPLC ChemStation and Acquisition.
Developing A Protein Purification Protocol Billie Parker
Qualitative Data Analysis. 2 In This Section, We Will Discuss:  How to load data files.  How to use Signal Options for data display.  How to apply.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
EZPump tm SSI Pump Control for EZChrom SI tm And EZChrom Elite tm.
Varian 920-LC Integrated Analytical HPLC
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
900-LC P. van Poppel – Field Support Specialist October 2009.
VARIAN, INC. HPLC Products
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
The characterization of Amino Acids and the Purification of Proteins Shawndell Powell High School for Medical Science Bronx, NY, Dr. Jeffrey O. Boles.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
HPLC – High Performance Liquid Chromatography
SSI Binary Gradient Pump Modular Simplicity. Ideal Gradient Characteristics Modular design Small foot print Easy Maintenance Compatible with stand alone.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
440-LC Fraction Collector
Waters HPLC Competitive Review
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
Protein Identification using 2D LC/MS/MS based on pH Gradient and Reverse Phase Separation Column Technology Inc.,
. : Introduction: We are testing end-user responses to a potential new chromatography platform for a leading bioprocessing supplier. This new product line.
Quick Start Guide for Flex Flow Pump
Dual-stream UHPLC separations on a new, compact, sample delivery system featuring simplified software automation for increased throughput in drug discovery.
Purification Of Proteins.
LIQUID CHROMATOGRAPHY
Real-time Concentration
LIAISON®: Instrument Overview
LIQUID CHROMATOGRAPHY
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Pompa Tenaga Surya The Complete Efficient Solar Water Pumping System.
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Automation of Sample Preparation for Trace Analysis Haibin Wan
Microsystems for selective gas sensing
High Performance Liquid Chromatography (HPLC)
PepDriver Controlling Liberty1
Varian 940-LC Analytical to Prep HPLC
AssayMAP Bravo for Automated Sample Preparation
Advancements in Gas Chromatography Analyzers - Keeping up with New Technology Chuck Runkle Gas Phase Product Specialist ASTS June 2013.
August 23, 2000 R.N. Dubois Dow Chemical
Overcoming Challenges in Elemental Speciation Techniques
Phoenix Family Overview Test with Confidence.
Ion Exchange Laboratory
Running the BioLogic DuoFlow Starter Kit
Diagnostics Analytical 920 LC Semi-Prep 940 LC
High Accuracy UV-VIS Spectroradiometer ( nm)
Setting up, testing and running LC-systems
Total HVAC Control from anywhere Easy control that can save a fortune
Varian 900-LC Series Galaxie Software
Downstream Processing
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
1. Downstream Processing: Purification
David Thornton1, Xiqin Yang1, Gary Yanik2 and Leo Hsu1*
Presentation transcript:

Introduction to the NGC Chromatographic System

Protein purification systems – yesterday & today Simplified, a chromatography system is just: Pumps Valves (Columns) Detector(s) Fraction Collector

NGC System Capabilities Technical Overview Open platform compatible with all medium pressure chromatography columns 10 ml/min or 100 ml/min system pumps Buffer inlet module and buffer blending module for scouting and automated buffer preparation Flexible sample loading options via sample loop (static or dynamic) and a dedicated sample pump all without the need to re-plumb the system, a C96 autosampler can also be connected to the inject valve Column switching module enables up to 5 columns be connected. Contains an internal bypass function for system priming, and reverse flow functionality for affinity chromatography elution and column cleaning Single wavelength detector (255/280nm), or multi-wavelength detector enabling the simultaneous measurement of 4 wavelengths (UV & Vis). Both detectors include an integrated conductivity monitor. pH module with integrated calibration port and bypass port Flexible fraction collection options from 96 well plates, to a range of tubes and large volume bottles Bulletins 6286, 6326, and 6608

A chromatography platform that aligns to your needs Quest™ & Quest™ Plus Workhorse system for the purification of proteins peptides and nucleic acids Scout™ & Scout™ Plus All purpose purification system with buffer scouting Discover ™ Versatile automated purfication system for advanced method development Yes, it does look similar to GE

Expandable system that grows with you Get what you need today with a single, scalable platform that grows and adapts to your throughput and purification needs over time Tier Expansion

Plug-n-Play Modular Design A truly modular design Plug-n-play modules can be easily moved within the system New modules can be added to expand system capabilities as your purification needs change Plug-n-Play Modules Note system must be switched off before modules are removed

ChromLab Software Highlights Touchscreen Intuitive Method Templates Column Library Scouting Multi-D Import GE Unicorn SW and Bio-Rad DuoFlow files Analysis made easy One click peak integration Easy overlay Fraction heat map Concentration determination User Management Edition and Security Edition FREE Bulletin 6675

The Heart of the System - Pumps Two versions available, 10 and 100 mL/min Buffer blending module allows for double flow and simplified buffer preparation ANYONE INTERESTED IN 100 ML/MIN PUMPS IS LIKELY INTERESTED IN BBV – 180 ML/MIN IS PREFERRED OVER 100 ML/MIN BECAUSE YOU ARE NOT REDLINING THE PUMPS – SAME FOR 18 ML/MIN ON 10 ML/MIN PUMPS

Inlets – Great for Automation A buffer inlet valve provides automated buffer switching.

Sample Loading – Volume is Key Volumes >10 ml use a sample loading pump with air sensor. Smaller volumes should be done with loops.

Column Switching Valve Allows reverse flow CSV can also serve as a “loop multiplier” allowing for up to 5 sample loops

Detectors – The “eyes” of the system Single wavelength for labs doing simple protein OR DNA purification Multi-Wavelength is great for labs that: Purify Protein/DNA complexes Purify a fluorescently labeled protein Purify a protein with no signal at 280nm Human Eyes Superman’s Eyes

Outlet – Large Volume Fractionation Useful for labs doing large volume work Able to save the “flow through” in one large container rather using the BioFrac

NGCTM system capabilities System Pump 10 ml/min, 25.2 MPa 100 ml/min, 10 MPa Single-WL Detector 255/280nm BioFracTM Fraction Collector Unlimited Options 180 x 12mm tubes 168 x 1.5ml tubes 120 x 15mm tubes 24 x 30mm tubes 4 x 96, 48-, 24- or 12-position micro-plates 20 x unlimited vol. adaptor Outlet valve Sample Inj. Valve No re-plumbing Column Valve Up to 5 col. Int. Bypass Reverse Flow Pre- & Delta Col. Pressure Conductivity Monitor 0.01 – 999 mS/cm Sample Pump Ideal for Affinity Integrated 100 ml/min, 10 MPa Int. Press. Sensor Buffer Inlet Valve (A/B) Up to 8 Inlets each Multi-WL Detector 190-800nm (UV/Vis) Up to 4 simultaneous 2, 5 & 10 mm Path lengths Buffer Blending Valve pH Scouting Doubles pump flow with gradient Air Sensor Protects Column Up to 8 Inlets (7 Buffers, 1 Sample) pH Probe & Valve In situ calibration Integrated bypass

Standout features Point-to-Plumb™ Pay for only what you need Infinitely configurable Tier expansion Columns mount anywhere Modules can go anywhere Free software—for life! Ten-second module swapping Highly intuitive software