GASMET DX4040 Antti Heikkilä 1.

Slides:



Advertisements
Similar presentations
Basic Scales | Robust, Fast, Portable Simple scales for all your applications and store formats.
Advertisements

Corporate Office: “4 B", 4th  Floor Bigjos ,Building No 8
GASMET DX4040 Antti Heikkilä.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
The physical parts of Computer
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
COMPUTER CONCEPTS Computer Information Systems. COURSE COMPETENCIES Explain the functions of computer system components. Describe the information processing.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
1 Electrical and Computer Engineering Cam Proctor Ramsey Khudairi Tom Gilbert Chad Young Project Orion TekBand.
ISolar Portable Solar Kit 4W. Front view of the solar panel while it stand Size: 20 x 23 x 3 cm, Weight: 390 gram.
DP Cabinet.
DataLogger Operation - 1 DataLogger ® Operation Procedures.
Computer Parts There are many parts that work together to make a computer work.
Computer Architecture Ports.  There are lots of external devices that you can connect to your computer. All external devices connect to the computer’s.
COMPUTER SYSTEM.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
COMPONENTS OF THE SYSTEM UNIT
Hardware specifications. Hard drive The hard drive is what stores all your data. It houses the hard disk, where all your files and folders are physically.
Unit 30 P1 – Hardware & Software Required For Use In Digital Graphics
Hardware Lesson 2 Computer Components. Path of Information Through a Computer Input Device RAM CPU Output Device.
World Leader In Gas Detection & Sensor Technology Stand Alone Calibration Station SM 2000 Series.
Computer Basics & Keyboarding. What Is A Computer? An electronic device operating under the control of instructions stored in its own memory unit An electronic.
Computer Hardware Introduction to Computer Components and Terminology.
I NTRODUCTION TO N ETWORK A DMINISTRATION. W HAT IS A N ETWORK ? A network is a group of computers connected to each other to share information. Networks.
Computer main parts HARDWARE It corresponds to all physical and tangible parts of a computer: your electrical, electronic, electromechanical and mechanical.
Camera Basics. Film (Analog) Cameras Digital Cameras Types of Cameras.
Quick Start Guide ST30/ST32 Series mobile computer.
Interfaces 101 Interfaces provide connectivity for the drawers to virtually any POS device (printer, terminal, tablet etc.) in the industry.
Voice Controlled Robot by Cell Phone with Android App
Unit Hardware Troubleshooting
Chapter Objectives In this chapter, you will learn:
Chapter Objectives In this chapter, you will learn:
Smart Phone Cradle (Option) Barcode Scanner (Option) RF Antenna Lamp for reading-status Status Display LCD Power Adopter USB Terminal Trigger.
Computer Information Systems
Avaya VA Line-interactive UPS
Last Update: 2-Jan-2005 Version: 1.0 Global Prepared By: John Lysfjord
USB flash drive A flash drive consists of a small printed circuit board carrying the circuit elements and a USB connector, insulated electrically and protected.
GammaTRACER Key features
Chapter 1 Getting Started
Datawind Calling Tablet Communication Redefined!
Computer Hardware – System Unit
Fujitsu Training Documentation Hardware Installation
mimio Training Developed by Marc Cooke, M.Ed. University of Delaware
Principles of Information Technology
MOBILE COMPUTING Jitendra Patel ROLL NO :- 38 TY MSC(CA & IT)
Drill Translate the following message:
Chapter 18 Buying a PC.
Creating a Media Server with a Raspberry Pi
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
Office 365 September 07, 2016.
Computer Basics.
Personal Computers and Applications
Introduction to Computing Lecture # 1
Product Training Module
IPad The best way to experience the web..
AQT90 FLEX Service Training
Quick Start Guide   Micrometer GM Pro 7.4.
Network Models, Hardware, Protocols and number systems
Hardware Components & Software Concepts
Stand Alone Calibration Station
Module 1 – Power Supply AMC APS-PBC-60
Module 1 Chapter 1. UNIT 2 – Hardware Basics  LESSON 1 – Basic Parts of A Computer  LESSON 2 – Buttons and Ports on A Computer  LESSON 3 – Inside A.
Chapter 4: Hardware for Educators
Bharat Electronics
TERMS AND CONDITIONS   These PowerPoint slides are a tool for lecturers, and as such: YOU MAY add content to the slides, delete content from the slides,
Presentation transcript:

GASMET DX4040 Antti Heikkilä 1

Complete redesign of the DX4040 New electronics New handheld computer New Calcmet Lite New battery New enclosure New accessories SAME INTERFEROMETER SAME SAMPLE CELL SAME DETCTOR

New mode of operation Analysis is removed from the electronics board to the PDA PDA stores several libraries Each PDA library has up to 200 gases PDA can analyse up to 50 gases Libraries can be changed easily Gases can be added and removed from analysis easily Limited editing of analysis settings also possible Analyser’s role more similar to traditional Gasmet DX4000, CX4000 models

New Enclosure Designed both for tabletop and backpack operation Battery completely inside the enclosure Tilted front panel for easier operation Polyurethane plastic, tough and chemical resistant Copper paint on inside ensures electromagnetic shielding and grounding Improved carrying harness and shoulder strap 4

New front panel Easy to use selector switch with 3 positions Bluetooth ON OFF Serial ON Battery charge indicator Battery can be charged in place Analyzer will run on 115/230 VAC with battery in place Accessible gas connectors Innovative connector cover plate

New front panel Battery indicator Red < 15% Flashing LEDs indicate malfunction Quick fittings Sample in Sample out Zero + Span in Interf. purge Power plug Charges battery while powering DX4040 with 115/230 VAC Serial port Cable terminates in standard RS-232 conncector USB converter can be used Power switch GREEN – RS232 NO LIGHT – off BLUE – bluetooth

New Battery 11.25 VDC Lithium Ion battery 13.6 Ampere-hour capacity (150 Watt continuous discharge for one hour) Smart Battery Standard – charge indicator LED’s on the battery and further diagnostics via USB from the charger Battery can be charged inside the analyzer as in laptop computers

New Battery Desktop charger available Diagnostics available in Calcmet Service mode via USB connector on desktop charger: % of charge Estimated remaining charge time Battery voltage Battery temperature Charge / discharge cycle counter

New accessories Carrying harness Easier to attach and remove More comfortable to carry Probe Less weight Better grip Extension tube possible with Swagelok 6 mm fitting

New PDA NAUTIZ X7 IP65, shockproof 806Mhz processor 128Mb/4Gb memory 3G/HSDPA and Wlan networking Bluetooth and RS-232 communications Built-in Camera and GPS    

New Calcmet Lite Calcmet Lite has been completely revised to include analysis of recorded spectra New PDA with more memory, faster processor and bigger screen enables other improvements as well: Better spectrum draw routine Sending results and spectrum files via WLAN or 3G modem (the PDA acts as a cell phone) Integrated GPS with coordinates saved in results file

Calcmet Lite v2.0 features On screen guidance Big buttons for START STOP ZERO

Calcmet Lite v2.0 features On screen guidance during measurement

Calcmet Lite v2.0 features Common procedures like zeroing are made easier Minimal training required for basic operation

Calcmet Lite v2.0 features Built in help file (opens in web browser) Contains same information as DX4030 quick reference cards

Calcmet Lite v2.0 features Hardware status contains OK / ERROR message listing the parameters, which are outside accepted ranges

Calcmet Lite v2.0 features Built-in protection against low memory card space problems Completely filling the system memory requires low-level reboot, losing all data

Calcmet Lite v2.0 Analysis settings Selecting an application

Calcmet Lite v2.0 Analysis settings Enabling and disabling components

Calcmet Lite v2.0 Analysis settings Editing component specific settings All settings can be edited on PDA Due to limited spectrum display options actual application development is best made with full version of Calcmet for Windows

Calcmet Lite v2.0 Analysis settings Editing component specific settings All settings can be edited on PDA Due to limited spectrum display options actual application development is best made with full version of Calcmet for Windows

Calcmet Lite v2.0 Analysis settings Editing component specific settings All settings can be edited on PDA Due to limited spectrum display options actual application development is best made with full version of Calcmet for Windows

Using DX4040 with Calcmet for Windows Calcmet 4030 Standard software is no longer needed, Calcmet Lite performs same functions Calcmet 4030 Pro software renamed Calcmet 4040 Pro remains DX4040 cannot be run from Calcmet for Windows without serial number specific HASP key New, improved simple mode, optimized for 7” tablet PC in Calcmet 12 (more in Calcmet presentation) New, improved simple mode, optimized for 7” tablet PC in Calcmet 12 (more in Calcmet presentation)

Comparison with DX4030 DX4030 DX4040 Analysis Within analyzer DSP board In new version of Calcmet Lite Application file Special text files (2) for DSP + LIB file for PDA Standard Calcmet LIB file Changing applications Only by uploading new files to analyzer with Calcmet Standard or Pro key Application can be changed and edited directly in PDA # of analysed gases Up to 25 Battery charging In external charger only, no charge indicator Inside analyzer or in external charger Battery status Not available Indicators on analyzer, charger and battery + full diagnostics in Calcmet Service mode GPS support no Yes Using full version of Calcmet Requires Calcmet Pro key

Availability and Pricing Orders accepted now First deliveries in December Base price will be slightly higher than DX4030 Better PDA and added features compensate for this DX4040 without any extras is more powerful than DX4030 with Calcmet 4030 Standard software and HASP key Calcmet 4040 Pro version priced in the same way as Calcmet 4030 Pro Price lists will be sent shortly after the meeting

Availability of DX4030 DX4030 will not be discontinued Availability in 2012 is guaranteed Ongoing public tenders and other long-term projects with the DX4030 will not be affected The need for DX4030 after 2012 will be assessed next year

27