Generator Rules and Regulation City of Livermore

Slides:



Advertisements
Similar presentations
Stored Fuel Maintenance Standards as Defined by NFPA Gregory Hagopian President FUEL TECHNOLOGIES INTERNATIONAL LLC PO BOX 6368, Santa Maria, CA
Advertisements

IRON & STEEL FOUNDRY MACT COMPLIANCE ASSURANCE
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Fired And Unfired Pressure Vessels
EPA Proposed Mandatory Greenhouse Gas Reporting Rule.
Air Permitting and Compliance Smithfield Foods Environmental Conference Chicago, IL July 2013.
Railroad Commission of Texas Statewide Rule 32 and Flaring/Venting of Produced Gas Travis Baer, District 01 Engineering Specialist August 2014.
RICE MACT and Oil Analysis
APAI Environmental Workshop FESOP Recordkeeping/Plans James (Jim) Heim, C.T.C., E.P. Bruce Carter Associates, L.L.C February 9, 2012.
“TI” Ohhhh….. (TIO) (No TIO is not a person!) What is it all about?
1 Permit Exemptions Rule Revisions North Carolina Division of Air Quality Permit Exemptions Rule Revisions North Carolina Division of Air Quality Stakeholder.
Compliance Update NCMA 2015.
Blue Skies Delaware; Clean Air for Life Stationary Generators, Regulatory Requirements and Permitting State of Delaware DNREC - Air Quality Management.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
CALIFORNIA AIR RESOURCES BOARD DIESEL EMISSIONS STANDARDS AL UPTON BUTTE COUNTY FLEET MANAGER  Four separate rules apply to Public Agencies  On-Road.
© Copyright, Yorke Engineering, LLC 2008 SCAQMD Rule Compliance Steps and Strategies Judy Yorke and Bipul K. Saraf Yorke Engineering, LLC
PESH The Public Employee Safety and Health Act Article 2, Section 27a, NYS Labor Law Effective January 1, 1980.
Maricopa County Air Quality Department 1001 North Central Ave. Phoenix, Arizona Maricopa County Air Quality Department Protecting and improving our.
Mustang Watchdog April 22, 2014
1 Improving Environmental Protection and Reducing Administrative Burden North Carolina Division of Air Quality Improving Environmental Protection and Reducing.
Our Vision – Healthy Kansans living in safe and sustainable environments.
Hydrogen Fuel Standards Division of Measurement Standards 6790 Florin Perkins Road, Suite 100 Sacramento, CA
Air What causes air pollution? Chapter 12 Section 1.
2007 Grant Programs to Reduce Air Pollution Public Workshop Feather River Air Quality Management District August 10, 2007.
GENERAL CONDITIONS: ARTICLE 39 DIESEL VEHICLE EMISSIONS CONTROL GENERAL CONDITIONS: ARTICLE 39 DIESEL VEHICLE EMISSIONS CONTROL Connecticut's Diesel Reduction.
1 Public Hearing to Consider Proposed Amendments to the Emission Inventory Criteria and Guidelines Regulation for the AB 2588 Air Toxics “Hot Spots” Program.
How will we enforce AB32? It's tough to make predictions, especially about the future. Yogi Berra It's tough to make predictions, especially about the.
Air Resources Board’s 2005 Distributed Generation Technology Review DG Workgroup Meeting June 2, 2004 California Environmental Protection Agency Air Resources.
Welcome Revisions of Chapter WAC Sections -035 and -036 Rule advisory committee workshop #5 Lacey, WA October 28, 2009.
Diesel Risk Reduction Plan California Environmental Protection Agency Air Resources Board.
Demonstration Testing l Purpose: Assurance that major monitors are able to detect a malfunction and illuminate the MIL with emissions below the malfunction.
Air Quality Aspects for Construction Projects Subcontractor On Boarding Series 05/2012.
Orange County Board of County Commissioners Chapter 15, Proposed Modifications to Article III Air Quality Control Environmental Protection Division June.
1 Permit Exemptions Rule Revisions North Carolina Division of Air Quality Permit Exemptions Rule Revisions North Carolina Division of Air Quality Air Quality.
Analytical Laboratories - Potential and Restricted Emissions Kevin Tyson, Air Quality Analyst Wednesday, December 10, 2014.
Public Workshop Proposed RACT/BARCT Determination for Stationary Spark-Ignited Internal Combustion Engines August 29, 2000 California Environmental Protection.
30th Space Wing Team Vandenberg - HAWKS 1 California Airborne Toxic Control Measures for Particulate Matter Emissions from Diesel-Fueled Engines John Gilliland.
PROPOSED AMENDMENTS TO THE STATEWIDE PORTABLE EQUIPMENT REGISTRATION PROGRAM California Environmental Protection Agency Air Resources Board June 22, 2006.
By Kai Evans and Andrew Duran
Main flexibility tools for the adoption of high emission standards for LCPs set in the new Industrial Emissions Directive Gerard Lipinski Coordinator of.
The City of Morro Bay has implemented Mandatory Water Conservation Requirements for Severely Restricted Water Supply Conditions 2013 has been the driest.
ADOPT UPDATED SEWER SYSTEM MANAGEMENT PLAN (SSMP) Sausalito CC 11FEB14.
1 Diesel Training and General Requirements Pennsylvania Bureau of Deep Mine Safety.
Carbon Monoxide Detection: Code and Legislation Updates
CODE REVIEW: DOH Article 28 Compliance
Complying with Periodic Emissions Monitoring Requirements
First in Service First in Value
Commissioner Christi Craddick Commissioner Ryan Sitton
Compliance and Enforcement Presentation to Industrial Association of Contra Costa County February 22, 2017 Paul Grazzini, Air Quality Specialist Bay.
The Florida Energy and Climate Commission (FECC)
ONROAD AND NONROAD VEHICLES EMISSION STANDARDS
Combustion BY AREEB.
Record Keeping Completing a Manure Management Plan Workshop
NEW General Permit-005A Emergency Generators
OFFICE OF THE CITY CLERK JULY 24, 2017 CERTIFICATION OF SUFFICIENCY OF A REFERENDUM PETITION AGAINST ORDINANCE NO ADOPTED BY THE PASADENA CITY.
PREVENTION OF AIR POLLUTION FROM SHIPS
What is the Boiler NESHAP?
Current as of 12/12/2017 RES-BCT.
Simple but Complicated Air Quality Permitting for Generators
29 CFR NFPA Life Safety Code
Air Permitting General Permit Updates
Common Control Self-Declaration form
CDE Transportation Unit
Enforcing the NAAQS Case Study Sean Taylor
FACILITY DOCUMENT REVIEW TRAINING
City Council Meeting November 14, 2016
New York City Department of Environmental Protection
National Fire Protection Association Update
Air Quality Permitting
Presentation transcript:

Generator Rules and Regulation City of Livermore Bay Area Air Quality Management District 375 Beale Street Suite 600 San Francisco, California 94105 Peter Nelson Senior Air Quality Inspector

Regulation 9 Rule 8 NITROGEN OXIDES AND CARBON MONOXIDE FROM STATIONARY INTERNAL COMBUSTION ENGINES 9-8-101 Description: This rule limits the emissions of nitrogen oxides and carbon monoxide from stationary internal combustion engines with an output rated by the manufacturer at more than 50 brake horsepower 9-8-110 Exemptions: The requirements of Sections 9-8-301 through 305, 501 and 503 shall not apply to the following: 110.1 Until January 1, 2012, engines rated by the manufacturer at less than 250 brake horsepower output rating. 110.2 Engines rated by the manufacturer at 50 brake horsepower output rating or less. Effective January 1, 2012. 110.3 Until January 1, 2012, engines fired exclusively by liquid fuels including, but not limited to, diesel fuel, gasoline, and methanol. 110.4 Engines used directly and exclusively for the growing of crops or the raising of animals. 110.5 Emergency standby engines. 9-8-112 Registered Portable Equipment: The requirements of this section shall not apply to an internal combustion engine registered as portable pursuant to the Statewide Portable Engine and Equipment Registration Program, Sections 2450-2465, Article 5, Title 13, California Code of Regulations.

9-8-330 Emergency Standby Engines, Hours of Operation: A person may only operate an emergency standby engine under the following circumstances: 330.1 For emergency use for an unlimited number of hours; and 330.2 Until January 1, 2012, for reliability-related activities so long as total hours of operation for this purpose do not exceed 100 hours in a calendar year, or limitations contained in a District permit, whichever is lower. 330.3 Effective January 1, 2012, for reliability-related activities so long as total hours of operation for this purpose do not exceed 50 hours in a calendar year, or limitations contained in a District permit, whichever is lower. Hours of operation for reliability-related activities may exceed these limits only as necessary to comply with testing requirements of National Fire Protection Association (NFPA) 25 – “Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems,” 1998 edition. 9-8-530 Emergency Standby and Low Usage Engines, Monitoring and Recordkeeping: Each emergency standby and low usage engine shall be equipped with a nonresettable totalizing meter that measures hours of operation or fuel usage. All records shall be kept for at least two years, and shall be available for inspection by District staff upon request. The operator shall keep a monthly log of usage that shall indicate the following: 530.1 Hours of operation (total) 530.2 Hours of operation (emergency) 530.3 For each emergency, the nature of the emergency condition

http://www.baaqmd.gov/permits/apply-for-a-permit

Questions and Answers

Peter Nelson 415 749-4979 pnelson@baaqmd.gov