Downstream Processing

Slides:



Advertisements
Similar presentations
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
Advertisements

Isofocusing Chromatography Prepared by- Shirin Akhter.
PURIFICATION OF GFP USING HIC CHROMATOGRAPHY. Chromatography  A technique used to separate molecules based on how they tend to cling to or dissolve in.
Size Exclusion Chromatography
Foundation GPC Training Course Theory. Nomenclature Gel Permeation ChromatographyGPC Size Exclusion ChromatographySEC Gel Filtration ChromatographyGFC.
Protein Purification Molecular weight Charge Solubility Affinity.
Bringing a Biotechnology Product to Market
Chromatography for Protein purification 1
Ion Exchange Laboratory. Today’s Schedule Pre-lab discussion Ion Exchange and Spectrophotometer Ion exchange experiment.
Downstream Processing in Biopharmaceutical Manufacturing
ION EXCHANGE CHROMATOGRAPHY PREPARED BY- MD.MARUF HASSAN.
Protein Purification Strategies Course: Methods in protein chemistry Rahman M. Mahfuzur 2012/01/11 SLU.
IEX Chromatography Presented by: Nikki Apostolakis Helen So Tiffany Yu CHEE450: Engineering Biology.
1. 2  A form of “partition chromatography”.  Stationary phase is a porous gelatinous matrix (in the form of beads).  Sample components enter pores.
Gel filtration Chromatography
HPLC when GC won’t cut it!!!. Types of HPLC Reverse-phase (water/MeOH-soluble) Normal Phase (very polar) Adsorption (very non-polar) Ion-Exchange (ionic)
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Cation Exchange Column CHEE450 Leslie Davis. Cation Exchange Following removal of biomass – processes supernatant Separate insulin precursor from glucose,
Chromatography Chapter 4 1 Dr Gihan Gawish. Definition Dr Gihan Gawish  Ion-exchange chromatography (or ion chromatography) is a process that allows.
Ion Exchange Laboratory
BIOMAN 2011 CHO-tPA Production System Downstream Processing
Chapter 4-1 Chromatography
High Performance Liquid Chromatography
Chromatography Chromatographic separation is based on distribution of separated compound (analyte) between mobile phase and stationary phase Richard Vytášek.
Types of Mechanism in the Chromatography
Magnet Analytical Chemistry Unit 4
Protein Purification and Analysis Solubility of proteins important for purification: 60-80% soluble, 20-40% membrane Size of proteins varies Some proteins.
Table 5-1 Protein Purification Essential for characterizing individual proteins (determining their enzymatic activities, 3D structures, etc.) Two main.
Analysis of Proteins and Peptides Amino acid composition Molecular weight Isoelectric point Subunit structure Prosthetic groups Solubility Biological activity.
Developing A Protein Purification Protocol Billie Parker
BIOCHEMICAL METHODS USED IN PROTEN PURIFICATION AND CHARACTERIZATION
Ion Exchange Laboratory
Bringing Biotech Product to Market Chapter 9. Objectives Purifying product Define chromatography and distinguish between planar and Column chromatography.
BIOMAN K. Lampe, MC3 U P S T R E A M D O W N S T R E A M B I O P R O C E S S I N G biosciences.com.
Lab 6 Salt fractionation In aqueous environments salt ions interact strongly with their complementary charge on a water molecule If the concentration of.
Downstream Processing
Chemistry 1- Separation Objectives: 1) Learn about 2 different separation methods.
Size Exclusion Chromatography. Proteins 75% of dry matter in living things is protein. Biologist must purify protein from other proteins in the cell.
Proteomics The science of proteomics Applications of proteomics Proteomic methods a. protein purification b. protein sequencing c. mass spectrometry.
Proteins separation and analysis using Fast Protein Liquid Chromatography Ayelet David, Ph.D Dept. of Clinical Pharmacology.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Protein Purification by Ion Exchange Chromatography
Protein Purification for Crystallization Dr Muhammad Imran Forman Christian College (A Chartered University) Dr Muhammad Imran Forman Christian College.
GEL FILTRATION CHROMATOGRAPHY Size Exclusion Chromatography
Lab 6 Ig Purification What will the Ig be used for? How pure does it need to be? What is the source of the antibody (serum, ascites, cell culture supernatant)
Chromatography PlanarColumn Paper TLC (Thin layer chromatography)
Principles of chromatography
Chromatography.
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
Bioreactor Harvest miniBIOMAN 2017
Purification Of Proteins.
BSB Biomanufacturing CHAPTER 13 GMP – Downstream Processes
Protein Characterization/Purification
Purification of Green Fluorescent Protein
Amino Acids, Peptides, and Proteins
Chapter 11 -Downstream Processing
Downstream Processing
Column Chromatography
Gel Filtration Chromatography.
INTRODUCTION  A membrane is a thin semi-permeable barrier which can be used for the following types of separation: 1. Particle-liquid separation 2. Particle-solute.
Biophysical Tools '04 - Chromatography
Chromatographic separation
Ion Exchange Laboratory
Principle of separation of different components:
M.S COLLEGE OF ARTS, SCIENCE, COMMERCE AND B.M.S
Purification of Green Fluorescent Protein
Experiment 3 Separation of proteins by Anion exchange chromatography
Presentation transcript:

Downstream Processing

Know the Characteristics of Your Protein Green Fluorescent Protein (GFP) Sequence of Amino Acids Tertiary Structure MSKGEELFTGVVPVLVELDGDVNGQKFSVSGEGEGDATYGKLTLNFICTTGKLPVPWPTLVTTFSYGVQCFSRYPDHMKQHDFFKSAMPEGYVQERTIFYKDDGNYKTRAEVKFEGDTLVNRIELKGIDFKEDGNILGHKMEYNYNSHNVYIMGDKPKNGIKVNFKIRHNIKDGSVQLADHYQQNTPIGDGPVLLPDNHYLSTQSALSKDPNEKRDHMILLEFVTAARITHGMDELYK

Green Fluorescent Protein (GFP) MW (molecular weight = 27,000 Daltons (27 kD) pI (isoelectric point) - 4.8 Hydropathicity (hydrophobicity) - hydrophobic amino acids make up GFP’s fluorophore; amino acids associated with the fluorophore are also hydrophobic

GFP Chromatophore - Hydrophobic

Downstream Processing in Biopharmaceutical Manufacturing Protein Purification Harvest by Centrifugation Clarification by Depth Filtration Sterile Filtration (MF) Tangential Flow Filtration (UF/DF) Low Pressure Liquid Column Chromatography MF=microfiltration with .1 to .22u (pore size) filters UF=ultrafiltration with e.g. 10,000Dalton (pore size) cut-off filters DF=diafiltration where you exchange buffers and/or concentrate protein of interest

1 day 24 days 31 days Purification 8 days Inoculum Fermentation Large Scale Bioreactor Wave Bag Seed Bioreactors Fermentation 150L Bioreactor 750L Bioreactor 5,000L Bioreactor 26,000L Bioreactor 1 day Media Prep Working Cell Bank Sub- Culture Inoculum Depth Filtration Collection Centrifuge Harvest/Recovery 24 days 31 days Harvest Collection Tank 1,500L Filter Chromatography Skid Anion Exchange Chromatography (QXL) Column Eluate Hold 8,000L 6,000L Protein A Chromatography 20,000L Hydrophobic Interaction Chromatography (HIC) Viral Inactivation 5,000L Anion Exchange Chromatography (QFF - Fast Flow) Post-viral Vessel 3,000L Viral Filtering Ultra Filtration Diafiltration Bulk Fill Purification 8 days

Protein Purification - Filtration Separate protein using pores in solid media - small pore excludes large proteins (and vice versa): Depth Filtration Tangential Flow Filtration Ultrafiltration Sterile Filtration Defiltration

Protein Purification – Liquid Chromatography Separate protein using different affinities for a solid media (matrix or bead) vs. liquid buffer: Hydrophobic Interaction Chromatography (HIC) Ion Exchange Chromatography (IEX): Anion Exchange Chromatography Cation Exchange Chromatography Affinity Chromatography Gel Filtration or Size Exclusion Chromatography

Methods to Remove Cells and Cellular Debris Centrifugation Depth Filtration

Centrifuge

Depth Filtration Cells and cellular debris stick to ceramic encrusted fibers in pads

Tangential Flow Filtration- TFF Used to separate of protein of interest Using TFF with the right cut off filters, the protein of interest can be separated from other proteins and molecules in the sterile filtered, clarified medium e.g HSA has a molecular weight of 69KD . To make sure that the protein of interest is retained, a 10KD cut-off filter is used After ultrafiltration perform defiltration with buffer used to prepare for affinity chromatography of HSA

How TFF Concentrates and Purifies a Protein of Interest

Low Pressure Liquid (Production) Chromatography The Media: Hydrophobic Interaction (HIC) Ion Exchange (Anion AEX and Cation CEX Exchange) Gel Filtration (=Size Exclusion) Affinity The System: Components and Processes

Hydrophobic Interaction Chromatography (HIC HIC media have high capacity and are economical and stable; capable of powerful resolution used in therapeutic antibody purification because part antibodies are found in membranes, are lipid soluble and therefore hydrophobic molecular mechanism relies on unique structural features- serves as an orthogonal method to ion exchange and affinity chromatography adsorption takes place in high salt and elution in low salt concentrations These special properties make HIC very useful in whole processes for bridging or transitioning between other steps in addition to the separation which is effected

Ion Exchange Chromatography Separates by Charge

Isoelectric Focusing or IEF If the pI of your protein (or the pH at which your protein is neutral) is known , you can place it in a buffer at a lower or higher pH to alter its charge If the pH of the buffer < pI, the protein of interest will become positively charged If the pH of the buffer > the pI, the protein of interest will become negatively charged

Liquid Column Chromatography Process PURGE Air from Column use Equilibration Buffer PACK Column with Beads (e.g. ion exchange, HIC, affinity or gel filtration beads/media) EQUILIBRATE Column with Equilibration Buffer LOAD Column with Protein of Interest in Equilibration Buffer WASH Column with Equilibration Buffer ELUTE Protein of Interest with Elution Buffer of High or Low Salt or pH REGENERATE Column or Clean and Store (NaOH)

Liquid Column Chromatography

GFP Chromatography (HIC) GFP moving through HIC column GFP band or peak moving through HIC column.

GFP Chromatography Droplet of GFP Droplet of GFP caught in ‘fraction collector’.

LP LC System Components Mixer for Buffers, Filtrate with Protein of Interest, Cleaning Solutions Peristaltic Pump Chromatography Column and Media (Beads) Conductivity Meter UV Detector

LP LC System Components- Peristaltic Pump Creates a gentle squeezing action to move fluid through flexible tubing

LC System Components UV Detector - detects proteins from the column by measuring absorbance at 280nm Conductivity Meter - measures the amount of salt in the buffers coming out of the columns – high salt or low salt are often used to elute the protein of interest from the chromatography beads

Height Equivalent to Theoretical Plate (HETP) HETP = L/N L=length of column in mm N=column efficiency allows comparison of columns of different lengths smaller the HETP the better shorter the column the better

Calculating Column Efficiency (N)

A Typical Chromatogram Eluate Flow Through If you were running HIC columns, the chromatogram produced would show flow through of (hydrophilic) proteins that do not attach to the HIC column, no proteins in the wash, followed by a peak of hydrophobic GFP eluted from the HIC column with low salt. Wash