M. Lichtwarck-Aschoff, A. Helmer, R. Kawati, M. Lattuada, U. H

Slides:



Advertisements
Similar presentations
Assessing the performance of the Whisperflow® continuous positive airway pressure generator: a bench study  G.W. Glover, S.J. Fletcher  British Journal.
Advertisements

Relationship of inspiratory and expiratory times to upper airway resistance during pulsatile needle cricothyrotomy ventilation with generic delivery circuit 
Increasing positive end-expiratory pressure (re-)improves intraoperative respiratory mechanics and lung ventilation after prone positioning  J Spaeth,
Nasal high-flow therapy delivers low level positive airway pressure
Is pulmonary resistance constant, within the range of tidal volume ventilation, in patients with ARDS?  G Mols, V Kessler, A Benzing, M Lichtwarck-Aschoff,
Isocapnic hyperpnoea accelerates recovery from isoflurane anaesthesia
Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients  A.
N.P. Talbot, P.A. Robbins, K.L. Dorrington 
M. Weiss, C. Doell, N. Koepfer, C. Madjdpour, K. Woitzek, V. Bernet 
Supplemental oxygen and surgical site infection: getting to the truth
G. Hedenstierna, L. Edmark, G. Perchiazzi 
The upper airway during anaesthesia
The effect of bi-level positive airway pressure mechanical ventilation on gas exchange during general anaesthesia  Yu G , Yang K , Baker A.B. , Young.
Double-lumen tubes and auto-PEEP during one-lung ventilation
New concepts of atelectasis during general anaesthesia
Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical spine immobilization  F Agrò, G Barzoi, F Montecchia 
W. Habre, T. Asztalos, P.D. Sly, F. Petak 
Static versus dynamic respiratory mechanics for setting the ventilator
High-frequency oscillation in adolescents
Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile  S. Wirth, M. Baur, J. Spaeth, J. Guttmann,
Respiratory resistance during anaesthesia with isoflurane, sevoflurane, and desflurane: a randomized clinical trial  V. Nyktari, A. Papaioannou, N. Volakakis,
High-frequency oscillatory ventilation and an interventional lung assist device to treat hypoxaemia and hypercapnia  David M. , Heinrichs W.   British.
Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques  A.L. Balogh, F. Petak, G.H. Fodor, J. Tolnai,
Phase behaviour of premixed 0
Lung protective strategies in anaesthesia
Preoxygenation: a comparison of three different breathing systems
Practical assessment of respiratory mechanics
Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study†  G. Wallon, A. Bonnet, C. Guérin  British.
Mind the gap when performing emergency front-of-neck access
H. Reissmann, W. Pothmann, B. Füllekrug, R. Dietz, J. Schulte am Esch 
O. Thom, D. M. Taylor, R. E. Wolfe, J. Cade, P. Myles, H. Krum, R
Improvement of lung mechanics by exogenous surfactant: effect of prior application of high positive end-expiratory pressure  A. Hartog, D. Gommers, J.J.
U. Goebel, J. Haberstroh, K. Foerster, C. Dassow, H. -J. Priebe, J
L.M. Ferguson, G.B. Drummond  British Journal of Anaesthesia 
Recent advances in gas exchange measurement in intensive care patients
J. Hofland, I. GuÕltuna, R. Tenbrinck  British Journal of Anaesthesia 
M.A. Olympio, R. Whelan, R.P.A. Ford, I.C.M. Saunders 
Modification of tracheal tubes
P. Michelet, A. Roch, D. Brousse, X. -B. D'Journo, F. Bregeon, D
A. Absalom, D. Amutike, A. Lal, M. White, G.N.C. Kenny 
Complete heart block during central venous catheter placement in a patient with pre- existing left bundle branch block  D Unnikrishnan, N Idris, N Varshneya 
Correction to the paper ‘Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study’  M Hallbäck,
Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult.
Maintenance of stable cuff pressure in the Brandt™ tracheal tube during anaesthesia with nitrous oxide  F. Karasawa, T. Okuda, T. Mori, T. Oshima  British.
Effects of carbon dioxide absorbent cooling and temperature gradient reduction on water condensation in the anaesthesia circuit  G. Hirabayashi, H. Uchino,
B. McNamara, J. Ray, D. Menon, S. Boniface 
New ventilators for the ICU—usefulness of lung performance reporting
Expertise in practice: an ethnographic study exploring acquisition and use of knowledge in anaesthesia  A. Smith, D. Goodwin, M. Mort, C. Pope  British.
The abdominal muscles in anaesthesia and after surgery
V. Uppal, G. Fletcher, J. Kinsella  British Journal of Anaesthesia 
S Singh, J.E. Smith  British Journal of Anaesthesia 
Tidal changes in PaO2 and their relationship to cyclical lung recruitment/derecruitment in a porcine lung injury model  D.C. Crockett, J.N. Cronin, N.
Anaesthesia for awake craniotomy—evolution of a technique that facilitates awake neurological testing  A. Sarang, J. Dinsmore  British Journal of Anaesthesia 
R.J. Roche, C. Mackinlay, A. McLaughlin, K. Panikkar, J.D. Young 
Positive pressure ventilation: what is the real cost?
Effects of tracheal tube orientation on the success of intubation through an intubating laryngeal mask airway: study in Mallampati class 3 or 4 patients 
Ventilation strategies in obese patients undergoing surgery: a quantitative systematic review and meta-analysis†  M. Aldenkortt, C. Lysakowski, N. Elia,
An appropriate inspiratory flow pattern can enhance CO2 exchange, facilitating protective ventilation of healthy lungs  L.W. Sturesson, G. Malmkvist,
Jet or intensive care unit ventilator during simulated percutaneous transtracheal ventilation: a lung model study  Y.H. Liu, A.L. Wang, A.D. Marchese,
Pressure-controlled ventilation improves oxygenation during laparoscopic obesity surgery compared with volume-controlled ventilation  P. Cadi, T. Guenoun,
Anaesthetic staff cannot identify extremely high tracheal tube cuff pressures by palpation of the pilot balloon  S.A. Michlig  British Journal of Anaesthesia 
P. Persson, O. Stenqvist, S. Lundin  British Journal of Anaesthesia 
J.-L. Vincent, M.M. Wilkes, R.J. Navickis 
Ventilation with the Ventrain through a small lumen catheter in the failed paediatric airway: two case reports  M.G.A. Willemsen, R. Noppens, A.L.M. Mulder,
Comparison of central venous and external jugular venous pressures during repair of proximal femoral fracture†  A.D. Leonard, C.M. Allsager, J.L. Parker,
Cross-tolerance between spinal neostigmine and morphine in the rat
Hayes-Bradley C   British Journal of Anaesthesia 
Another case of obstruction to an anaesthetic circuit
Alveolar recruitment in acute lung injury
Remote measurement of the leak around the uncuffed tracheal tube: objective measurement and physical characteristics  A.J. Sims, K. Keltie, C.A. Reay,
Presentation transcript:

Good short-term agreement between measured and calculated tracheal pressure  M. Lichtwarck-Aschoff, A. Helmer, R. Kawati, M. Lattuada, U.H. Sjöstrand, N. Zügel, J. Guttmann, G. Hedenstierna  British Journal of Anaesthesia  Volume 91, Issue 2, Pages 239-248 (August 2003) DOI: 10.1093/bja/aeg169 Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 1 Tracings of calculated and measured tracheal and proximal airway pressure in a representative animal during VC without PEEP. Pprox (dotted line): Airway pressure measured at the proximal outlet of the tracheal tube; measured Ptr (heavy line): tracheal pressure measured directly at the carina; calculated Ptr (1) (thin line): PRohrer calculated according to 4; calculated Ptr (2) (thin line): PBlasius–Ito calculated according to 2. British Journal of Anaesthesia 2003 91, 239-248DOI: (10.1093/bja/aeg169) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 2 Tracings of calculated and measured tracheal and proximal airway pressure in a representative animal during PS. Pprox (dotted line): Airway pressure measured at the proximal outlet of the tracheal tube; measured Ptr (heavy line): tracheal pressure measured directly at the carinal level; calculated Ptr (1) (thin line): PRohrer calculated according to 4; calculated Ptr (2) (thin line): PBlasius–Ito calculated according to 2. British Journal of Anaesthesia 2003 91, 239-248DOI: (10.1093/bja/aeg169) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 3 Tracings of calculated and measured tracheal and proximal airway pressure in a representative animal during bi-level positive airway pressure (BiPAP) ventilation. Pprox (dotted line): Airway pressure measured at the proximal outlet of the tracheal tube; measured Ptr (heavy line): tracheal pressure measured directly at the carinal level; calculated Ptr (1) (thin line): PRohrer calculated according to 4; calculated Ptr (2) (thin line): PBlasius–Ito calculated according to 2. British Journal of Anaesthesia 2003 91, 239-248DOI: (10.1093/bja/aeg169) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 4 Agreement between calculated and measured tracheal pressure (PRohrer calculated according to 4) during VC with a PEEP of 12 cm H2O in surfactant-deficient animals. Bias and limits of agreement are indicated for distinct pressure points: 0.1 s after start of inspiration; peak airway pressure; 0.25 s past peak; 0.5 s past peak; 1 s past peak; last end-expiratory point. British Journal of Anaesthesia 2003 91, 239-248DOI: (10.1093/bja/aeg169) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 5 Flow-dependent resistive pressure decrease over the tracheal tube when ID is 7.5 mm (top) and when ID is 8.0 mm (middle). Assuming a constant inspiratory flow pattern and a narrowing of the native ID 8 tracheal tube to a 7.5 ID tracheal tube, the flow-dependent error in calculated tracheal pressure PRohrer is depicted at the bottom (deviation from true Ptr). When narrowing is from 8 to 7.5 mm ID and flow is 18 litre min−1, the calculated PRohrer overestimates the true Ptr by 0.11 cm H2O; with 48 litre min−1 overestimation is 1.06 cm H2O, and with 90 litre min−1 overestimation is 3.98 cm H2O, respectively. British Journal of Anaesthesia 2003 91, 239-248DOI: (10.1093/bja/aeg169) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions