Electron Paramagnetic Resonance Biodosimetry in Teeth and Fingernails

Slides:



Advertisements
Similar presentations
CONFIDENTIAL R.S.I. CORPORATION University Based Safety Training Personal Monitors.
Advertisements

Radiation Safety Innov-X Systems X-Ray Fluorescence
CHPPM-EUROPE RADIATION PROTECTION DIVISION
Radiation Safety Course: Biological Effects
Sensitivity of Human Lymphocytes to Low-Dose Radiation
The Electromagnetic Spectrum
Principle of Electron Spin Resonance dating ESR dating in earth sciences and achaeology refers to the effect of accumulated radiation in a mineral relative.
X-Rays In Medicine Noadswood Science, 2013.
Radiation Dosimetry and Safety Thomas H. Hauser MD, MMSc, MPH, FACC Director of Nuclear Cardiology Beth Israel Deaconess Medical Center Assistant Professor.
Electromagnetic Waves
Estimation of TLD dose measurement uncertainties and thresholds at the Radiation Protection Service Du Toit Volschenk SABS.
G.R.Eaton, S.S.Eaton, K.Ohno, EPR imaging and In vivo EPR
Electron Spin Resonance Spectroscopy
Essentials of Environmental Health PH 203 Dr. Khaled El-Ezaby
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
CP Physics Ms. Morrison.  Moving charged particles create magnetic fields  Changing motion of charged particle creates expanding and collapsing magnetic.
Radical Recombination Kinetics. Objectives To synthesize a dimer, which upon irradiation, undergoes dissociation to a radical Determine the order and.
Introduction Radiosensitive polyacrylamide gels (PAG) provide a method of mapping dose distributions in 3D with sub-millimetre resolution [1]. Largely.
Imaging Science FundamentalsChester F. Carlson Center for Imaging Science Medical X-ray Imaging System Imaging Science Fundamentals.
Radiation Exposure, Dose and Relative Biological Effectiveness in Medicine Background Image:
Chapter 15 Molecular Luminescence Spectrometry Molecular Fluorescence  Optical emission from molecules that have been excited to higher energy levels.
Electromagnetic Waves
Prof.Dr. Gehan Mosaad. At the end of this lecture the student must be able to:  Define electrotherapy, electric current and electromagnetic spectrum.
Electron Paramagnetic Resonance spectrometer
Radiology is concerned with the application of radiation to the human body for diagnostically and therapeutically purposes. This requires an understanding.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Chris Roy September 28 th 2010 MBP 1028 Optical, Thermal and Radiation Biophysics Principles of Radiofrequency and Microwave Heating.
Electron Paramagnetic Resonance at Hunter College
Electron Spin Resonance Spectroscopy
Common types of spectroscopy
Principles of Magnetic Resonance
Atomic Emission Spectroscopy
IAEA International Atomic Energy Agency Basics of Biodosimetry Part 1 Lecture Module 2.
Magnetic Resonance Imaging
Radiation. Ionising Radiation Alpha Radiation Beta Radiation Gamma Rays X-Rays Neutrons.
Chapter 31 Nuclear Energy; Effects and Uses of Radiation.
Personal Radiation Dose IONIZING AND NON-IONIZING RADIATION Non-ionizing: Carries LESS energy Can only excite the water molecule. Ionizing: Carries MORE.
L 36 Modern Physics [2] How lasers work Medical applications of lasers Applications of high power lasers Medical imaging techniques CAT scans MRI’s.
Biological Dosimetry in Radiation Accidents Andrzej Wojcik Department of Radiobiology and Health Protection Institute for Nuclear Chemistry and Technology.
Introduction to Radioisotopes: Measurements and Biological Effects
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
1. 2 Radiation Safety 3 What is Radiation? Radiation is a form of energy. It is emitted by either the nucleus of an atom or an orbital electron. It.
Training Module 3 – Version 1.1 For Internal Use Only ® Radiation Therapy 
DNA Damage and Biodosimetry
Introduction to Electron Spin Resonance and Spin Trapping
Mechanical and fluidic integration of scintillating microfluidic channels into detector system 1 Davy Brouzet 10 th September 2014.
Ferris State University & Michigan Department of Career Development 1 Radiation Safety Answer Key.
30.1 X-rays and radioactivity
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Presented by Ms. Kanokwan Boonsook Date: 8 June, 2016
5.5 Medical Applications Using Radioactivity
Absorbed dose of radiation and its biological influence
Radiation Protection Omar Desouky Review article Submitted by:
ECEN5341/4341Bioelectromagnetics
CHAPTER 12 Radiation.
Chapter 4 Nuclear Chemistry
Electromagnetic Radiation
Bystander Effects.
ECEN5341/4341Bioelectromagnetics
Atomic Absorption Spectroscopy
Magnetic Susceptibility
Medical Physics Physics 421 Course Description:
Health Effects of Radiation
4.3 Light and the Electromagnetic Spectrum
ECEN5341/4341Bioelectromagnetics
Irradiation of Polarized Target Materials
Molecular Luminescence Spectrometry
Radiation and YOU .
at the University of Alabama
Presentation transcript:

Electron Paramagnetic Resonance Biodosimetry in Teeth and Fingernails A. Romanyukha1,2, R.A. Reyes2, F. Trompier3, L.A. Benevides1, H.M. Swartz4 1Naval Dosimetry Center, 8901 Wisconsin Ave., Bethesda, MD, 20889, USA, 2Uniformed Services University, 4301 Jones Bridge Rd., Bethesda, MD, 20814, USA, 3Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-roses, France, 4Dartmouth Medical School, Hanover, NH, 03755, USA

Outline EPR dosimetry basics In vitro X and Q dosimetry in tooth enamel In vivo tooth L-band dosimetry EPR dosimetry in fingernails Conclusions

What is Electron Paramagnetic Resonance (EPR) ? Non-destructive magnetic resonance technique used to detect and quantify unpaired electrons. Absorption of ionizing radiation generates unpaired electrons (i.e., paramagnetic centers). The concentration of radiation-induced paramagnetic centers is proportional to the absorbed dose.

EPR: Fundamentals and Principles There is a net absorption of energy from the microwave field at resonance because of a greater population of electrons are in the lower energy state. The process is non-destructive because the population difference reestablishes itself after the microwave field is turned off. Thus, the history of radiation exposure is not destroyed by EPR measurements.

Electron Resonance Optical Imaging

Typical frequencies and wavelengths required for resonance of a free electron in EPR measurements Mw Band Frequency, GHz Magnetic field, T Sample size L 1.5 0.05 Small animals, whole human teeth, fingers in situ S 3.2 0.11 Whole teeth, fingers X 9.5 0.33 30 - 1000 mg (solid) K 20 0.70 10 – 30 mg (solid) Q 35 1.22 2 – 10 mg (solid) W 95 3.30 0.25 – 1 mg (solid)

EPR dosimeters for partial body exposure Radiation-induced radicals are stable only in hard tissues: teeth, bone, fingernails and hairs. Depending on mw band EPR can be measured in vivo or in vitro using specially prepared samples from human hard tissues Finger- and toenails Finger- and toenails

Characteristics of EPR dosimetry Non-invasive Based on a physical process Not affected by biological processes such as stress Not affected by simultaneous damage that is likely to occur with irradiation such as wounds & burns Applicable to individuals Measurements can be made at any interval after irradiation up to at least 2 weeks (fingernails) or indefinately (teeth) Can provide output immediately after the measurement Unaffected by dose rate Can operate in a variety of environments Systems can be developed so that they can be operated by minimally trained individuals

In vitro measurements in tooth enamel samples (X and Q-bands)

Extracted teeth can be available for in vitro EPR measurements

Validation and Standardization Four successful International Dose Intercomparisons with totally more than 20 participating labs ICRU, 2002. Retrospective Assessment of Exposures to Ionizing Radiation. Report 68 (Bethesda, MD: ICRU). IAEA, 2002. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. International Atomic Energy Agency, Vienna, IAEA-TECDOC-1331. EPR dosimetry with teeth is the only method which can reconstruct external gamma radiation doses (<100 mGy) individually.

Steps of the method Tooth collections Tooth enamel sample preparation EPR measurements of radiation response Calibration of EPR radiation response

EPR Biodosimetry (Teeth)

EPR Biodosimetry (Teeth) Hydroxyapatite constitutes: ~95% by weight of tooth enamel 70-75% of dentin 60-70% of compact bones Romanyukha, et. al, Appl. Radiat. Isot. (2000) and IAEA-TECDOC-1331

EPR Biodosimetry (Dose Calibration)

EPR Biodosimetry Applications (Epidemiological Investigations Using Tooth EPR) Description of group Year of over-exposure Number of reconstructed doses Values of reconstructed doses, Gy Reference Survivors of a-bombing of Hiroshima, Japan 1945 100 0.3-4.0 Gy Nakamura et al., Int. J. Radiat. Biol. 73, 619-627 (1998) Mayak nuclear workers, Russia 1948-1961 ~100 0.2-6.0 Gy Wieser et al., Radiat. Env. Biophys. 2006 Romanyukha et al., Health Phys. 78, 15-20 (2000) Techa riverside population 1948-1958 0.1-10 Gy Romanyukha et al., Health Phys., 81, 554-566 (2001) Romanyukha et al., Radiat. Environ. Biophys., 35, 305-310 (1996) Eye-witnesses of Totskoye nuclear test, Russia 1954 10 0.1-0.4 Gy Romanyukha et al., Radiat. Prot. Dosim., 86, 53-58 (1999). Chernobyl clean up workers, Ukraine 1986 660 0 - 2.0 Gy Chumak et al., Radiat. Prot. Dos. 77, 91-95 (1998) Population of areas contaminated by Chernobyl fallout, Russia 2500 ~ 0.1 Gy Stepanenko et al., Radiat. Prot. Dos. 77, 101-106 (1998) Semipalatinsk population 1950s 32 Romanyukha et al., Appl. Mag. Res.., 22, 347-356 (2002)

Conclusion EPR X-band (9 GHz) dosimetry in tooth enamel works excellent (LLD<100 mGy, time after exposure when dose measurements are possible from 0.01 hr to 106 yr. But it requires to have extracted or exfoliated teeth available for preparation of tooth enamel

exfoliated/extracted teeth Alternatives to exfoliated/extracted teeth L-band (1.2 GHz) non-Invasive in vivo measurements Q-band (35 GHz) measurements in enamel “biopsy” samples (~2 mg) with followed up tooth restoration

Q-band (35 GHz) measurements in enamel “biopsy” samples (~2 mg) with followed up tooth restoration

Description of Q-band feasibility test Tooth enamel powder samples for test: 0; 0.1 Gy; 0.5 Gy; 1 Gy; 3 Gy; 5 Gy Each sample was recorded 3 times in X (100 mg) and Q bands (2, 4 mg) Recent publication Romanyukha A. et al. Q-band EPR biodosimetry in tooth enamel microprobes: Feasibility test and comparison with X band. Health Physics. 93, 631-635, (2007).

X-band spectrum vs Q-band spectrum X-band (100 mg), 0.1 Gy Q-band, (4 mg) 0.1 Gy Q-band has significantly lesser amount of the sample required for dose measurements Q-band has significantly better spectral resolution of dose response

Dose dependence: X vs Q

Dental Biopsy Technique With the enamel biopsy technique a small enamel chip is removed from a tooth crown with minimal damage to the structural integrity of the tooth. A high-speed compressed-air driven dental hand piece is used with appropriate dental burs for this purpose. Standard techniques for tooth restoration using light-cured composite resins rapidly restore the small enamel defect in the biopsied enamel surface of the crown. Preliminary study on discarded teeth have demonstrated the feasibility of removing 2 mg enamel chips, the desired size for sufficient sensitivity with Q-band EPR dosimetry. Biopsy Whole Tooth In collaboration with B. Pass, P. Misra, T. De (Howard University)

Q-band biopsy experiment Tooth enamel biopsy sample 2.2 mg was irradiated 4 times to the same dose - 4.3 Gy After each irradiation angle dependence (12 positions) of biopsy sample was studied Using average, maximum, minimum and median values of EPR radiation response at each dose (e.g. 4.3, 8.6, 12.9 and 17.1 Gy) and linear back extrapolation attempt to reconstruct dose of 4.3 Gy was made

Angle dependence of radiation response Possible approaches: 1. Use average value of radiation response at each dose; 2. Use maximum value of radiation response at each dose; 3. Use minimum value of radiation response at each dose; 4. Use median value of radiation response at each dose.

Spectra in biopsy sample at different doses and dose dependences Appearance of tooth enamel spectrum (maximum) of the same biopsy sample 2.2 mg at different doses Dose dependences for average, maximum, minimum and median values of radiation response at each dose

Results of attempt to reconstruct 4. 3 Gy in biopsy sample (2 Results of attempt to reconstruct 4.3 Gy in biopsy sample (2.2 mg) using different approaches Approach Result of linear back extrapolation Average values 5.5 ± 0.8 Gy Maximum values 7.3 ± 3.6 Gy Minimum values 5.4 ± 0.7 Gy Median values 5.4 ± 1.4 Gy

Preliminary conclusions Tooth enamel biopsy spectra have slightly different shape from powder spectra, they are more narrow and have higher signal-to-noise ratio for the same dose than powder spectra. However existence of angle dependence for biopsy spectra makes difficult dose reconstruction. Possible solution is to use average, maximum, minimum or median values for each dose for dose reconstruction Use of average and minimum EPR radiation response values gives the best results to reconstruct 4.3 Gy, e.g. 5.5 ± 0.8 Gy and 5.4 ± 0.7 Gy, respectively A possible reason for some dose offset (~1 Gy) is a slope of a base line of the spectra for this sample A possible solution is to apply base line correction to spectra before measurements of peak-to-peak amplitude of radiation response

L-band in vivo

Recent publications Swartz H.M. et al. Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ. Appl. Radiat. Isot. 62, 293-299 (2005) Swartz H.M. et al. In Vivo EPR Dosimetry to Quantify Exposures to Clinically Significant Doses of Ionizing Radiation. Radiat. Prot. Dosim. 120, 163-170 (2006). Swartz H.M. et al. In Vivo EPR for Dosimetry. Radiat. Meas. 42, 1075-1084, (2007).

L-band (1 GHz) of microwaves is better for realization of in vivo EPR than standard X-band (9 GHz) because it has Greater tolerance for the presence of water Relatively large sample volume sufficient for whole tooth.

Components of in vivo EPR spectrometer Resonators that will probe teeth in vivo Magnet system that can comfortably and effectively encompass the human head Software for EPR dose response determination Dose calibration for in vivo L-band measurements

Clinical EPR Spectrometers

Retrospective Radiation Dosimetry

In Vivo EPR Radiation Dosimetry Under practical conditions with an irradiated tooth in the mouth of a volunteer, the dose dependent signal amplitude is clearly observed. (Acq. time = 4.5 minutes/spectrum)

EPR Dose Response

Dose-dependence for 6 in vivo teeth, with each tooth irradiated to a different dose and measured on 3 separate days. Linear regression analysis shows that the standard error of dose prediction is ± 46 cGy.

EPR biodosimetry in tooth enamel for partial body dose assessment X-band EPR is ready to use for forensic dose assessment. Could be carried out on compact and transportable (< 150 kg) EPR spectrometer. Dose level <100 mGy. Q-band biopsy potentially is able to measure doses < 500 mGy in biopsy tooth enamel samples 2-4 mg. L-band in vivo EPR potentially is able to measure doses as low as 3 Gy. Needs some additional development.

Finger-and toenails facts Typical available amounts of nail parings are up to 120 mg for fingernails and up to 160 mg for toe nails Nails grow all the time, but their rate of growth slows down with age and poor circulation Fingernails grow at an average of one-tenth of an inch (3 mm) a month. It takes 6 months for a nail to grow from the root to the free edge Toenails grow about 1 mm per month and take 12-18 months to be completely replaced The nails grow faster on your dominant hand, and they grow more in summer than in winter The major component of fingernails is a a-keratin. This protein is built up from three, long a-helical peptide chains that are twisted together in a left-handed coil, strengthened by S – S bridges formed from adjacent cisteine groups.

Recent development Romanyukha A. et al. EPR dosimetry in chemically treated fingernails. Radiat. Meas. 42, 1110-1113, (2007). Trompier F. et al. Protocol for emergency EPR dosimetry in fingernails. Radiat. Meas. 42, 1085-1088, (2007). Reyes R.A. et al. Electron paramagnetic resonance in human fingernails: the sponge model implication. To be published in Radiat. Env. Biophys. (2008)

New insights in EPR fingernail dosimetry Fingernails can be considered as a sponge-like tissue which behaves differently from in vivo fingernails when mechanically-stressed after clipping Most of previously published results on EPR fingernail dosimetry were obtained on stressed samples and not applicable to life-scenario situation Unstressed fingernails have more significantly stable and sensitive radiation response which can be measured with EPR

Radiation-induced signal in unstressed fingernails RIS spectra obtained by subtraction of BKS spectrum recorded prior irradiation RIS parameters: g=2.0088 DH=9 G

Result of dose reconstruction in the sample irradiated to 4 Gy 5 days before reconstruction Reconstructed dose 3.66 Gy, reduction

Variability of dose dependence in fingernails

Dosimetric properties of fingernails Optimal sample mass is 15-20 mg (nail-parings from 2-3 fingers) Measurements time 5 minutes (10 scans) Achievable lower dose threshold ~ 1 Gy RIS fading half-time 300 hr (~2 weeks)

Conclusions Part of body EPR band/freq LLD, Gy in vivo/ amount Time stability Tooth enamel X 0.1 50 – 100 mg 106 yr Q 0.3-0.5 2-4 mg Tooth L 3-5 In vivo Finger-nails 0.5-1 20-30 mg ~2 wks

Acknowledgements G. Burke, E. Demidenko, C. Calas, I. Clairand, T. De, O. Grinberg, A. Iwasaki, M. Kmiec, L. Kornak, B. LeBlanc, P. Lesniewski, P. Misra, C. Mitchell, R.J. Nicolalde, B. Pass, A. Ruuge, D.A. Schauer, J. Smirniotopoulos, A. Sucheta, T. Walczak

Disclaimer The views expressed in this presentation are those of the author and do not reflect the official policy or position of the Navy and Marine Corps Public Health Center, Navy Bureau of Medicine and Surgery, Department of the Navy, Department of Defense, or the U.S. Government.

www.Biodose-2008.org