F Aero Diffusion Technical Specifications CryptoScent®

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

ACTIVE LEARNING PROCESS
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
HVAC CONTROLS (See section 18.9)
Setup/Installation/Operation of an Environmental Control Unit (ECU)
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Installation. Indoor Unit Installation Typical Installation.
Mate Grinder MATE European Dealer Meeting Advantages of Automatic Controlled Punch and Die Grinding More regrinds, accurate material removal Protect.
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
TrueSTEAM™ Humidification Systems Module 3: Basic Installation.
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
TrueSTEAM™ Humidification Systems Module 4: Advanced Installation.
Experiment 8 : Minor Losses
HVACR312 - Refrigeration Metering Devices.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
GAMMA & ROAD TUBE BASICS TRAINING
Installation. Indoor Unit Installation Typical Installation.
Product Introduction.
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
STEAM HEATING.
Hydronic Mechanical Controls
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
GIDC DEGREE ENGINEERING COLLEGE BRANCH- CIVIL ENROLLMENT NO PATEL SHARADKUMAR KIRITBHAI SHARMA TANISHQ SHAH ASHIT.
Important variables Water: Air: Conversion:
Installation. Indoor Unit Installation Typical Installation.
Settings & Adjustments. Settings & Adjustments.
The DUCTZ Experience. A Brief Overview of how DUCTZ Cleans a Heating and Cooling System.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
Suggestion for installation Demolish and destroy the old air condition, then send them to owner building Install a new one by last main.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Air condition installation
Technical Seminar on Application and Technical Specification June 2016
Chapter 6 technology institute of HAVC from usst INDUSTRIAL VENTILATION TUTORIAL 王丽慧.
VIEW SERIES with Sliding Door
Select your System Freedom Micro DI.
Maturing and cold smoking
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Fan Coil Controller FC/S 1.1
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
Easy centering and setting system
Heating, Ventilating, and Air Conditioning
Heating Ventilating and Air Conditioning
Techniques in Molecular Biology 2017 Fall Lecture -2-
EVAPORATIVE EMISSION CONTROL SYSTEMS
Air Distribution Control
Internal Training Module
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Techniques in Molecular Biology 2017 Fall Lecture -2-
Use and Maintenance of Micro-pipettes
Heating, Ventilating, and Air-Conditioning
Commercial Stainless Steel Freezers
Wiring the Light and Relay
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
By: JAGDEEP SANGWAN Refrigeration Basics 101.
FBE03: Building Construction & Science
Smokes extraction principle
F Aero Diffusion Technical Specifications ArtyScent®
F Aero Diffusion Technical Specifications IconoScent®
The DUCTZ Experience 1.
The DUCTZ Experience 1.
BabyCart Facilitates power and oxygen to transport incubator
Presentation transcript:

F Aero Diffusion Technical Specifications CryptoScent®

Table of Contents Introduction p.1 Technology p.5 Precautions p.6 General Maintenance p.7 Programming p.8 Installation p.13 Specifications p.19 Aero Diffusion Technical Specifications 2014 2

Introduction Aero Diffusion Technology® can be applied by 3 different devices that cover every need. The devices have been designed in order to respond to the demands of any project or area. They are fully programmed and ergonomical. Aero Diffusion Technical Specifications 2014 3

CryptoScent® CryptoScent® has been designed in order to aromatize any kind of large scale spaces through the central ventilation system. It can be applied directly on the HVAC or to the supply duct of the central air-conditioning system. CryptoScent® ensures 100% area coverage of large spaces and is suggested in highly demanding projects. Aero Diffusion Technical Specifications 2014

Technology Aero Diffusion appliances of Spring Air thanks to the patented diffusion system that they use, they can ensure the conversion of the liquid fragrance into ultra fine droplets ,distributing them at an average of 1.000 nanometers (1 micrometer μm) in diameter. What can be characterized as being unique concerning the Aero Diffusion Technology® is the small droplet diameter and the extra light weight of the droplet that can ensure uniform scent distribution. In performance terms, Aero technology droplets convert liquid into vapor very fast. This ensures the absence of residues on surfaces within the scented area. Very important parameter is that the scent effect, which is created, cause very low concentration of fragrance in the air, usually less than 1PPM which is below the international standards for allergic response. The perfect diffusion of the fragrance into the area can be achieved with the complete programming of the devices. Each device can be programmed for every day separately into two different zones. Thus, given that capability, the aromatization of each space is feasible. Aero Diffusion Technical Specifications 2014 5

CryptoScent® Appliance Precautions The appliance must be operated in an upright or vertical position and firmly attached to a vertical surface such as a wall or a duct. The appliance should NOT be used with the door in the open position. The door is opened only to perform a cartridge or program change. NEVER put your nose to the output of CryptoScent®. Within 12 inches of the output, the fragrance is highly concentrated. The improper inhalation of high concentrations of fragrance may cause irritation in eyes and respiratory. The appliance is built to be plugged into an 110VAC or 220VAC power outlet. The UL and CE compliant power supply converts power to 12V DC to power the appliance. Unplug before cleaning Aero Diffusion Technical Specifications 2014 6

General Maintenance Changing the Cartridge Unlock and open the door to access the cartridge: The door should be opened only to perform a cartridge or programming change. When in use, the doom must be locked. Detach metal hose connector from the cartridge output port (located on the top of the cartridge head). This is done by unscrewing the metal connector from the cartridge output port and pulling out. Remove air nozzle (located on the top of the cartridge head) Remove old cartridge from appliance enclosure Insert air nozzle on the new cartridge Install new cartridge, place and tighten metal hose connector firmly on cartridge output port Close the door and the device to secure Aero Diffusion Technical Specifications 2014 7

Programming Day & Time programming We press CLOCK and the indication HOUR is displayed. Using the + button we set HOUR Aero Diffusion Technical Specifications 2014 2) We press and the indication MINUTES is displayed. Using the + button we set MINUTES 3) We press . The days of the week will be shown on the screen. Using the + button we move the cursor to the current day 4) We press SET and the day & time programming has been completed 8

Programming 24-hour programming We press 24/7 for 3 seconds and the indication 00 is flashing in the right part of the screen Aero Diffusion Technical Specifications 2014 2) Using the + button we choose one of the 49 intensity options that device programming can give us 3) We press SET and the 24-hour programming has been completed Note: The device has 49 pre-installed programs in which the fragrance intensity can be adjusted. For example , in program 01 the intensity of the fragrance is the lowest and in the program 49 is the highest 9

Programming Daily customized programming We press PR button for 3 seconds and we have the days of the week on the screen. Using the + button we move the cursor among the days and with the button we underline the days that we want to function Aero Diffusion Technical Specifications 2014 We press SET and the indication is ON1 for the chosen days from step 1. Using the + button we adjust the time in which we want the device to start operating and we press Using the + button we adjust the minutes of the starting working hour of the device 3) We press SET and the indication is OFF1 for the chosen days from step 1. Using the + button we adjust the time in which we want the device to stop operating and we press Using the + button we adjust the minutes of the ending working hour of the device (Continue on page 11) 10

Programming Daily customized programming 4) We press SET and the indication 00 is flashing in the right part of the screen for the days we have chosen. Using the + button we choose one of the 49 installed programs (intervals) of the fragrances intensity Aero Diffusion Technical Specifications 2014 5) We press SET and we have the remaining days on screen that need programming. Using the + button we move the cursor under these days and with the button we underline the days that we want to adjust 6) We repeat STEPS 2,3, 4 and 5 until to complete all the days of the week a) Note in the step 4 of the programming: After the adjustment of the Interval if we choose SET and at the same time button instead of SET only, we have the indication ON2 for the chosen days. Repeating steps 2,3 and 4 we can program a second function zone for the chosen days b) In case we want for day the device to be OFF ex. Sunday we program the Internal 1 00 for that specific day. (Continue from page 10) 11

Programming STEPS We press CLOCK and the indication HOUR is displayed. Using the + button we set HOUR Aero Diffusion Technical Specifications 2014 2) We press and the indication MINUTES is displayed. Using the + button we set MINUTES 3) We press . The days of the week will be shown on the screen. Using the + button we move the cursor to the current day 4) We press SET and the day & time programming has been completed 12

Installation It is important to find an insertion point where the plume output will be smoothly drawn into and mixed with the airflow. This usually means those parts of the AHU where the static pressure is negative. Ideal locations include: Before the supply fan with injection through the wall of the AHU. Positioning immediately before the fan and after the coils if possible or in the mixed air chamber. Outside the AHU in the Supply duct. Best practice when installing in an AHU is to place the injection tube after the heating and cooling coils. If this not possible, the Plume output can pass over hot water, steam, chilled water, and DX coils. Aero Diffusion Technical Specifications 2014 13

Installation The best location for the Appliance is below the injector tube. The injector hose should be run upward as short a distance as possible and NEVER MORE THAN 20 cm. If an upward injector hose run is not possible, care should be taken support the hose to prevent sagging or any low spot in the run to avoid any possibility of condensation and liquid collection which will block the plume output. Give the hose a light upward slant along its run. The hose must not be run horizontally. A strong tape (such as Venture tape) may be used to support short runs. Aero Diffusion Technical Specifications 2014 14

Installation Injector tube CryptoScent ® 15 Aero Diffusion Technical Specifications 2014 Injector tube CryptoScent ® 15

Installation Aero Diffusion Technical Specifications 2014 16

Injector Tube installation The appliance is wall- mounted. Place the appliance onto the desired location on the wall or AHU and ensure that is level. Fasten the metal base of the appliance to the wall or AHU using necessary screws. Connect the power cord to a junction box or attach an AC plug to the cord and connect to a nearby outlet Secure the appliance Injector Tube installation The injector tube is installed directly into the AHU or ductwork. Its orientation can be adjusted relative to airflow. For installations into the negative/ suction side of the AHU fan, orient the tube with the elbow pointed upwards, so that any plume condensation will sip back in the tube. Aero Diffusion Technical Specifications 2014 17

Installation For installations after the supply fan, such as in a supply duct, it is necessary to configure and orient the Injector Tube to obtain a good aspiration of the output into the air stream. The injector tube should be pointed in the direction of the airflow and inclined approximately 45° upward. Turbulence in the airflow can prevent even aspiration of the plume. It is best to place the tube in a straight section of duct, and far away from turns. Branches, or cross- section changes as practical, and not immediately after the supply fan. At the insertion point, drill a hole using a ½“ drill bit. Insert the Injector Tube through the hole Find an orientation of the injector Tube that appears to produce a good draw of air into the end of the barb. Fasten the flange using the three #10 sheet metal screws. Turn the appliance on and verify that a plume is produced Attach the Injector hose into the hose barb of the Injector Tube Aero Diffusion Technical Specifications 2014 18

Specifications CryptoScent® Technical Characteristics Reference CryptoScent® Type Cold Evaporation Diffusion device Diameter of particles 300nm to 1μ micron Power Input Input 100 - 240 VAC at 0.6 A Frequency 50/60 Hz Protection Switching power supply Internal Power 12 VDC at 1.5 A Back-up battery Lithium 3V, #CR2032 Performance Up to 4.000 m² subject to air flow conditions Control Programmable start & stop times Programmable output 1 to 49 Dimensions Height x width x depth 37cm x 28cm x 20cm Weight with full container 6,600 kgs Cartridge Reservoir 1000ml Disposable/Recyclable Patented Spring Air Aero Diffusion Technical Specifications 2014 19

Revolutionary solutions for different needs…