Programs and techniques based on ROOT package for acquisition and sorting of the list mode data of the neutron detectors Elena Litvinenko1, Andrey Bogdzel1,

Slides:



Advertisements
Similar presentations
Components of GIS.
Advertisements

Overview of the current TDR system Introduction Electronics for instrumentation TDR core : Metronome, ADC, Merge Data Handling Pete Jones, University of.
Pete Jones University of Jyväskylä INTAG Workshop GSI, Germany May 2007 Status of digital electronics at JYFL Pete Jones Department of Physics University.
2D Detectors DAQ Overview 2D detectors are organized as tiles providing 10G Ethernet serialized portions of the full.
28 August 2002Paul Dauncey1 Readout electronics for the CALICE ECAL and tile HCAL Paul Dauncey Imperial College, University of London, UK For the CALICE-UK.
6 June 2002UK/HCAL common issues1 Paul Dauncey Imperial College Outline: UK commitments Trigger issues DAQ issues Readout electronics issues Many more.
Frank L. H. WolfsDepartment of Physics and Astronomy, University of Rochester Using Digital Signal Processing in the Advanced Laboratory F. Wolfs, M. Alexander,
4 Dec 2001First ideas for readout/DAQ1 Paul Dauncey Imperial College Contributions from all of UK: result of brainstorming meeting in Birmingham on 13.
Trigger-less and reconfigurable data acquisition system for J-PET
Pocket Multi-channel Signal Analyzer IIntroduction Key Features Applications Key Specifications Hardware Connections.
Ana Fernandes Real-time tools and algorithms for gamma spectroscopy Doctorate in Fusion Science and Engineering | IPP Garching | Sept. 30 th, 2009.
Developing a DSP Core using an FPGA Prototype for Scintillation Detector Signals Submitted to: Communication & Electronics Dept., Al Azhar University.
Shuei MEG review meeting, 2 July MEG Software Status MEG Software Group Framework Large Prototype software updates Database ROME Monte Carlo.
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
Data Acquisition Systems
New Nuclotron Beam Intensity Monitoring Subsystem V. Andreev, A. Butenko, A. Kirichenko, S. Romanov, G. Trubnikov, V. Volkov Veksler and Baldin Laboratory.
FOX AVL SYSTEM Satellite vehicle locating, tracking and fleet management.
David N. Brown Lawrence Berkeley National Lab Representing the BaBar Collaboration The BaBar Mini  BaBar  BaBar’s Data Formats  Design of the Mini 
A Front End and Readout System for PET Overview: –Requirements –Block Diagram –Details William W. Moses Lawrence Berkeley National Laboratory Department.
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Building a Decision Engine for Neutron/  Measurements FI eld-Programmable D etection.
GAYA Analyzer SDD Presentation. GAYA Analyzer Introduction OMS40G256 is a hardware device used for detection of radioactive radiation for medical imaging.
Sub-Nyquist Sampling Algorithm Implementation on Flex Rio
W.Skulski APS April/2003 Eight-Channel Digital Pulse Processor And Universal Trigger Module. Wojtek Skulski, Frank Wolfs University of Rochester.
Dec.11, 2008 ECL parallel session, Super B1 Results of the run with the new electronics A.Kuzmin, Yu.Usov, V.Shebalin, B.Shwartz 1.New electronics configuration.
W.Skulski Phobos Workshop April /2003 Digital Pulse Processor DDC-8 (Universal Trigger Module) for PHOBOS. Wojtek Skulski University of Rochester.
Event Mode Data Acquisition System Richard Riedel, Oak Ridge National Laboratory.
SoLID simulation with GEMC Zhiwen Zhao 2015/03/26.
Operated by Los Alamos National Security, LLC for the U.S. Department of Energy's NNSA UNCLASSIFIED LANSCE Beam Diagnostics R&D Presented by James Sedillo.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
New digital readout of HFRAMDON neutron counters Proposal Version 2.
Rutherford Appleton Laboratory September 1999Fifth Workshop on Electronics for LHC Presented by S. Quinton.
Elena Litvinenko, Feodosiy Levchanovsky, Valentin Prikhodko, Sergey Kulikov, Valeriy Zhuravlev FLNP JINR Dubna
Vladimir Zhulanov for BelleII ECL group Budker INP, Novosibirsk INSTR2014, Novosibirsk 2014/02/28 1.
Recent development of gaseous position-sensitive thermal neutron detectors for the IBR-2 spectrometers A.V.Belushkin, A.A.Bogdzel, A.N.Chernikov, A.V.Churakov,
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
DeLiDAQ-2D ─ a new data acquisition system for position-sensitive neutron detectors with delay-line readout F.V. Levchanovskiy, S.M. Murashkevich Frank.
Software Design of Electronics Tests and Data Acquisition for a New Gas Detector ZHAO Dongxu 1, 2 ZHANG Hongyu 2 YUE Xiaobo 1 ZHAO Yubin 2 CHEN Yuanbo.
Digital Acquisition: State of the Art and future prospects
Transient Waveform Recording Utilizing TARGET7 ASIC
"North American" Electronics
DAQ ACQUISITION FOR THE dE/dX DETECTOR
EET 2259 Unit 12 Data Acquisition
Data transmission system for 2D-SND at CSNS
HZB Proposal for a – New Readout Board for Delay Line Detectors
RF acceleration and transverse damper systems
GammaTRACER Key features
2007 IEEE Nuclear Science Symposium (NSS)
JEDI polarimetry – Developments at SMART|EDM_Lab
Front-end and VME / VXI readout electronics for ASICs
MoNA detector physics How to detect neutrons. Thomas Baumann NSCL.
T. Eberl for Robert Lahmann and the Erlangen acoustic group
Data acquisition systems on neutron spectrometers of the IBR-2 reactor
96-channel, 10-bit, 20 MSPS ADC board with Gb Ethernet optical output
DCH FEE 28 chs DCH prototype FEE &
Presentation of Vision System
Embedded Systems Design
Overview of AMADEUS and Positioning for KM3NeT
PADME L0 Trigger Processor
Magnet Safety System for NA61/Shine
Vertex 2005 November 7-11, 2005 Chuzenji Lake, Nikko, Japan
Software Implementation of USB 3.0 Stack
Laboratory Information System (LIS)
הודעות ריענון מהיר והרחבות Charts & Graphs גרף XY בניית מחולל אותות
CLAS12 Timing Calibration
Data Acquisition (DAQ)
Jupiter and Satellites
Readout Systems Update
Embedded Sound Processing : Implementing the Echo Effect
DAQ and visualization software
Presentation transcript:

Programs and techniques based on ROOT package for acquisition and sorting of the list mode data of the neutron detectors Elena Litvinenko1, Andrey Bogdzel1, Andrey Churakov1, Feodosiy Levchanovsky1, Lutz Rossa2, Olaf-Peter Sauer2, Thomas Wilpert2 1FLNP JINR Dubna 2HZB Berlin litvin@nf.jinr.ru

FLNP JINR flnph.jinr.ru

Outline Software requirements from the detector group About list mode data acquisition Delay line detector signals What is DeLiDAQ-1 DeLiDAQ-1 list mode options DeLiDAQ-1 data structure and format Why ROOT ROOT file with list mode data ELLADA program CaDeLin program E.I.Litvinenko 18 Oct 2016

The software requirements from the detector group in FLNP detailed diagnostic tools autonomy (stand-alone operation, independence from the experiment control systems and local database management systems, etc.) fast deployment flexibility (flexible configurability of parameters, easy modifications, configurable visualization tools) compact data formats easy integration into the experiment control software (via communication components or via components which can be used autonomously) extensibility E.I.Litvinenko 18 Oct 2016

About list mode data acquisition Listmode - a special measurement mode in which each event and its precise time of occurrence (timestamp) is recorded sequentially, with selected properties. List mode data can be used as a diagnostics tool to verify the performance of the detection system, but also to find time correlations between signals. Acquisition of data in list mode is known since 1985. Before 2000 - the analog electronics (values from ADC stored together with a timestamp). After 2000 - the digitizers that collect the signals directly from the detector output (pre-amplifier or photo-multiplier) with rate ~10 MHz In recent years – the digitizers with sampling rates up to 5 GS/s. Recent digitisers use DSPs and FPGAs equipped with algorithms for data reduction embedded in the digitiser's firmware. Now -new international standard for the data format for list-mode digital data acquisition used in radiation detection and measurement is being developed (TC45 of IEC) E.I.Litvinenko 18 Oct 2016

Delay line detector signals MWPC – ³He-2D Detector Delay line detector signals EMBL, DENEX (300x300 mm²) ~200 wires/plane

DeLiDAQ-1 systems at the FLNP (used since 2005) Detector (2D PSD)PreamplifiersDiscriminator  DeLiDAQ-1 < PCI < PC software PC E.I.Litvinenko 18 Oct 2016

List mode: encoded event data (DeLiDAQ-1) conventional raw list mode conventional filtered list mode packed list mode 0x00kmxxxx  0xkmiibbbb  0x00tttttt  0x0080xxxx  0x0081xxxx   0x0082xxxx  0x0083xxxx   0x0084xxxx  0x(8-F)xxx(0-7)xxx  0x(8-F)xxx(8-F)xxx E.I.Litvinenko 18 Oct 2016

Example of DeLiDAQ-1 data file structure DeLiDAQ-1 file (.root) Meas_1 Board_Param_run1 H1D_X1+X2_run1 H2D_X1-X2_Y1-Y2_run1 H3D_TOF_X1-X2_Y1-Y2_run1 Meas_2 H_Dead_run2 ReadListMode_run3 FPGA_ListMode (tree) Requested histograms [One file] [Folders] [Histograms; Parameters; Trees] E.I.Litvinenko 18 Oct 2016

Why DeLiDAQ-1 saves data to ROOT files Every day, thousands of physicists use ROOT applications to analyze petabytes of data or to perform simulations. E.I.Litvinenko 18 Oct 2016

ROOT file with list mode data The file sizes in bytes divided to the number of good events (i.e. number of bytes per good event in the file). Real world examples of the DeLiDAQ-1 list mode data from the detector. Mode (all TOF): Binary file: ROOT tree file: Raw (2D) (Ideal value 32) 36; 55 21; 30 Filtered (2D) 16 11 Packed (2D) 4 - Raw (1D) (Ideal value 24) 64 34 Filtered (1D) 12 8 E.I.Litvinenko 18 Oct 2016

Revealing the problems (examples)

ELLADA program Designed for express-analysis of the list mode data from the neutron spectrometer based on a proton telescope with electronic collimation of recoil protons, developed and created in the FLNP. Raw input data, collected using the digitizer N6724, produced by Caen, and CAEN MC2 Analyser software (10 ns timestamp resolution). ELLADA converts the raw binary data to root file with four independent ROOT trees (lmp,lm1,lm2,lm3) At the next step ELLADA performs the building of the events: lm0: t, e (timestamp, energy) lm1: t, e LM: t0,e0,t1,e1,t2,e2,t3,e3 lm2: t, e lm3: t, e E.I.Litvinenko 18 Oct 2016

ELLADA interface E.I.Litvinenko 18 Oct 2016

CaDeLin program Designed for data acquisition and express-analysis of the list mode data from the delay line neutron detectors, developed and created in the FLNP. Raw input data measurements using the digitizer N6730 (running DPP-PHA firmware ), produced by Caen (2 ns timestamp resolution). The raw data are saved directly to root file with several (from 5 to 8) independent ROOT trees (lm0,lm1,lm2,lm3,…,lm7) The data sorting (building of the events) is performed later lm0: t, e, w, … (timestamp, energy, waveform,…) lm1: t, e, w, … LM: tof,x1,x2,y1,y2 …. lm5: t, e. w, … E.I.Litvinenko 18 Oct 2016

CaDeLin measurements with detector E.I.Litvinenko 18 Oct 2016

References [ROOT] Brun R, Rademakers F 1997 Nucl. Instrum. Meth. A 389(1) 81-6, See also http://root.cern.ch [List Mode Standard developments] http://www.iec.ch/dyn/www/f?p=103:23:0::::FSP_ORG_ID,FSP_LANG_ID:1244,25 [DeLiDAQ-1 (the most recent publication)] Litvinenko E I, , Ryukhtin V, Bogdzel A A, Churakov A V, Farkas G, Hervoches Ch, Lukas P, Pilch J, Saroun J, Strunz P, Zhuravlev V V 2017 Upgrade of detectors of neutron instruments at Neutron Physics Laboratory in Řež Nucl. Instruments Methods Phys. Res. A 841 5–11 http://www.sciencedirect.com/science/article/pii/S0168900216310531 (free access to the article until 4-Dec-2016) [Proton telescope] Milkov V M, Panteleev T T, Bogdzel A, Shvetsov V N, Kutuzov S, Borzakov S B and Sedyshev P V 2012 Physics of Particles and Nuclei Letters 9(6) 508-16 [Caen] http://www.caen.it Paepen J, Peerani P, Schillebeeckx P, Tomanin A and Wynants R 2013 Use of a CAEN digitiser for nuclear safeguards and security applications with a scintillator detector JRC Sci. Tech. reports JRC87790. doi: 10.2787/87780 E.I.Litvinenko 18 Oct 2016