Pacemakers, Cardioverters, and Defibrillators

Slides:



Advertisements
Similar presentations
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Seventh Edition ©2011 by Pearson Education, Inc., Upper Saddle River, NJ.
Advertisements

Dual Chamber Temporary Pacing Operations & Troubleshooting
Pacemakers & Pacing in the ED Albury Wodonga Education Program 2014.
Temporary Pacemakers Karim Rafaat, MD.
Department of Anesthesia and Perioperative Care advancing health worldwide TM Combined ICD/Pacing Devices What options are available? What’s new in the.
Pacemaker Malfunctions Even less amusing!. Pacemaker Codes (NASPE/BPEG) Position I IIIII Category Chamber(s) Chamber(s) Response to paced sensed sensing.
The Very Basics of Pacing Glenn Estell Medtronic Pribcipal Clinical Specialist.
Modes of Pacing Seoul National University Hospital
Cardiac Assist Devices
Jennifer Cohen, MD, Heather Costa, PhD, Robert Russo, MD, PhD, Division of Cardiovascular Diseases, Scripps Clinic, La Jolla, CA The MagnaSafe Registry:
Pacemakers and Implantable Cardioverter-Defibrillators
Appendix E Pacemakers Gail Walraven, Basic Arrhythmias, Sixth Edition ©2006 by Pearson Education, Inc., Upper Saddle River, NJ.
Artificial Pacemakers and Anesthesia
Pacemakers and Implantable Defibrillators
The Electrical Management of Cardiac Rhythm Disorders Bradycardia Device Course The Electrical Management of Cardiac Rhythm Disorders, Bradycardia, Slide.
Juan Camilo Diaz Cardiac Pacemakers.
Anesthetic Management of Cardiac Rhythm Management Devices N746: Summer 2014 Jennifer Ranieri.
Dr.Gharibzadeh Alaleh Rashidnasab
Problems of creating physiologically matched artificial cardiac pacemakers Sergei Ovsjanski Tallinn University of Technology 2009.
Pacemaker & its Classification
Artificial Pacemaker: The Heart
Pacemakers and Implanted Defibrillators Mike Harlan.
Pacemaker Emergencies Arun Abbi MD Jan 21, Overview Initial approach Pocket Complications Acute complications with placement Nonarrythmic complications.
Single Chamber Temporary Pacing Operations & Troubleshooting.
Basic Concepts—Electricity and Pacemakers Module 3
Pacemakers and Implantable Cardioverter Defibrillators Chapter 10
Arrhythmias/Pacemakers trouble shooting
Rhythm Strips Jessica Wagner UMSON. EKG Grid.
Pacemakers, "Heart Sleeve" and the Economics
Basic Cardiac Pacing Claire Regan MSc Chief Cardiac Physiologist UHSM 2009.
AV Blocks Artificial Pacemakers Terry White, RN, EMT-P.
Mar 20, 2008 ECG Rounds Yael Moussadji, R4. Case 1.
Pacemakers.
Device and Antiarrhythmic Drugs: Advantages and Pitfalls Teresa Menendez Hood, M.D.
ECG in Pacemaker Malfunction
Pacemakers and AICD ’ s. Pacemaker Basics Provides electrical stimuli to cause cardiac contraction when intrinsic cardiac activity is inappropriately.
The Case for Rate Control: In the Management of Atrial Fibrillation Charles W. Clogston, M.D. Cardiologist CHI St. Vincent Heart Clinic Arkansas April.
Implantable Cardioverter Defibrillator (ICD) Reprogramming Guidelines Lauren Butler.
Supparerk Prichayudh M.D
Cardiovascular Therapeutic Management 2013
Basics of Pacemaker Functioning
Cardiology for Dr. Pelaez By Sai Kumar Reddy American International Medical University, St.Lucia.
Heart Blocks and Pacing
Staff Anesthesiologist – Allegheny Health Network
ECG RHYTHM ABNORMALITIES
Atrial fibrillation J Heinsimer MD.
CARDIAC PACEMAKER Ms. Saranya N 27-Feb-18 Cardiac Pacemaker.
Questions included for Critical Care Competency Day
Pacemaker for beginners
Pacemaker : overview Chennai: Feb2017
Temporary Pacemakers.
Pacemaker II Lecture (6).
Cardiac Pacemakers new 10 Oct 12 D McMahon.
Pacemakers and Implantable Cardioverter-Defibrillators
PACEMAKER Yoga Yuniadi
Laurie Racenet, FNP, MSN, CCDS, CEPS, FHRS
Arrhythmia Arrhythmia.
Pacemakers and AICD’s.
Pacemakers.
Dysrhythmias Disorders of formation or conduction (or both) of electrical impulses within heart Can cause disturbances of Rate Rhythm Both rate, rhythm.
Pacemakers and Devices – Interactive Session
EKGs and Pacemakers Cooper University Hospital
Diathermy and its safe use
Cardiac Implantable Electronic Devices
David D. Berg et al. JACC 2018;71:
The Electrical Management of Cardiac Rhythm Disorders Tachycardia Brady Therapy.
Electrocardiography for Healthcare Professionals
Cautery (ELECTRO MAGNETIC INTERFERENCE) & cardiac devices in endoscopy
Learn from the past and prepare for a better future
Presentation transcript:

Pacemakers, Cardioverters, and Defibrillators By: Lauryn Rametta, CRNA

Pacemaker Basics Pacemakers sense and pace the heart Sense the voltage produced by the heart (mV) and respond by sending (or not) electrical current (mA) to the heart Think of a pacemaker as a drug delivery device. The drug it delivers is electrons. The current it is delivering is the dose (electrons/second)

Pacemaker Basics Pacemakers are made up of: A pulse generator with a computer and battery that should last 6-10 years Leads placed in the right atrium and/or right ventricle and sometimes left ventricle Unipolar vs bipolar leads Unipolar leads less likely to fail but bipolar leads produce a sharper signal

Pacemaker Leads Passive Active

AICD Basics AICDs are made up of: A pulse generator with a computer and battery Battery is designed to deliver 120 shocks and usually lasts 3-6 years A lead electrode that detects dysrhythmias, delivers defibrillating shocks, paces, telemetry, and provides diagnostic data Many AICDs also have a 3rd lead (beyond the R atrial and ventricular leads) in the coronary sinus that can pace the left ventricular wall in synchrony with the right ventricle These are CRT-Ds (cardiac resynchronization therapy defibrillator) Without the defibrillation capability, these are merely bi-ventricular pacers or CRT pacemakers AICDs programmed to recognize VF or VT. If VF is detected, should deliver a shock within 10-15 seconds (needs time to charge) If VT is detected, it will treat with overdrive pacing

Why does my patient have this device? Good question. Always determine the underlying pathology that bought your patient this expensive device. What type of device is it? When was it placed? Are they pacer dependent? What is their underlying rhythm? Have they ever been shocked? When? How often? Has the pacer been interrogated recently?

Why does my patient have this device? Sinus node dysfunction Symptomatic bradycardia AV node dysfunction 3rd degree or type two 2nd degree heart block, symptomatic 1st degree or type one 2nd degree heart block Heart failure Sustained or recurrent VT/VF Other conditions such as alternating BBB, myotonic muscular dystrophy, neurocardiogenic syncope, cardiac transplant with persistent bradycardia, congenital heart diseases The list goes on…

Why Do We Worry About Pacemakers/ICDs in the OR? Risk of electromagnetic interference which can lead to: Inhibition of pacemaker Inappropriate delivery of shock by ICD Changes in parameters “Runaway” pacemaker Reprogramming Transient or permanent loss of capture Device failure Myocardial burns Minimize the risk by: Use of bipolar cautery Placement of grounding pad so that the current does not cross the generator Short bursts of monopolar cautery Have magnet available

Low Budget Pacemaker

Basic Electricity Review Voltage (measured in mV) The potential of the electrons if you cared to actually deliver them. Think of batteries (12v, 1.5v, etc.). They just sit there holding potential power until you use them. Current (measured in mA) The delivery of electrons. This is your dose (electrons/sec) Ground (earth) Basically where all the extra electrons get dumped so they don’t get dumped in you or a patient or anything else

Basic Electricity Review Ohms Law Current depends on voltage and resistance Voltage (V) = Current (I) x Resistance (R) V = IR Why do we care about all this?

Electricity Example Lets pretend you plug in 2 electrical wires to separate grounded outlets and then place those wires on a patient. One ground has a voltage of 0.1v and the other has a voltage of 0.5v. Your wires are really awesome and cutting edge. They have 0 resistance. What does this mean for your patient??

Electricity Example Ohms law: ∆V = IR We know V (0.1 and 0.5) and R (0 because of our amazing wires), so let’s rearrange our equation. I = ∆V/R Solve it. What does this mean?

Oops. You just killed your patient Infinity is a lot of electricity to send through a person. Probably try not to do that. This is called a “ground loop.” This is why all of the electricity in the OR is isolated. Ground 0.5 V Ground 0.1 V

I thought this lecture was about pacemakers? That example was on a macro scale but pacemakers, defibrillators, etc. follow these same laws and principles but from within the body and directly connected to the heart. This principle of grounded vs ungrounded has an impact on pacemaker interference as well

Pacemaker Vocab When talking about pacemakers in the most basic sense – whether they function or not – we focus on sensitivity, threshold, and inhibition. Sensitivity is the lowest voltage that must be achieved for a pacemaker to sense an R wave or P wave Threshold is the minimum current needed to pace the ventricle/atrium Inhibition refers to whether or not the pacemaker delivers a current. Basically whether it paces or just sits there doing nothing. Inhibition is determined by the pacemaker sensing electrical activity (from the heart or other sources such as cautery) Remember the inhibiting is done to the pacer, not by it. Pacemakers can only make the heart beat faster, they cannot slow it down!

Sensitivity Sensitivity is the lowest voltage that must be achieved for a pacemaker to sense an R wave or P wave You control the sensitivity. What happens if your sensitivity is too high/too low?

Sensitivity In order to make a pacemaker more sensitive you have to lower the sensitivity voltage.

A note on Atrial Sensing P wave sensing works on the same principle as we’ve described for R wave sensing You set an atrial sensitivity level that must be crossed in order to sense a P wave One exception Atrial sensitivity might also be set off by the T wave and that would be bad. So, for atrial sensing, the pacemaker senses an R wave and then waits. It waits for a refractory period and then assumes the next thing after that refractory period that crosses the atrial sensitivity level is a P wave. Sensitivity Level

Pacemaker/ICD Codes VOO, DOO, AOO, DDD, AAI, VVI, DVI – what does it all mean? ICDs have a 4 letter code and pacemakers have a 5 letters code. In this lecture, we will focus on the first 3 letters of the pacemaker code Pacemakers I: Chamber(s) paced II: Chamber(s) sensed III: Response to sensed event IV: Programmability, rate responsive V: Multisite pacing ICDs I: Chamber(s) shocked II: Antitachycardia Pacing Chamber(s) III: Tachycardia Detection E: Electrogram H: Hemodynamic IV: Antibradycardia Pacing Chamber(s)

A A I Pacemaker Codes O: None A: Atrium V: Ventricle D: Dual (A + V) or (Trigger + Inhibit) I: Inhibition Chamber Paced Chamber Sensed Response to Sensed Event

Pacemaker Code Practice Here are some common pacemaker codes you may encounter. Make sure you know what they each mean. DDD VVI VOO AOO DVI AAI

What Happens if a Pacemaker Senses Something Besides a Heartbeat? If you have a pacemaker that is programmed to inhibit (VVI, for example) it will sense this interference and inhibit its pacing Inhibition = no pacing = no heartbeat in a pacemaker dependent patient = Bad news

Pacemakers in the OR So, your patient has a pacemaker and is coming in for surgery. No big deal right? You’ve read their chart, and the cardiologist has made them low risk for surgery. You’re in a hurry so you haven’t had time to ask a lot of questions about the pacemaker but your attending tells you to put a magnet on the pacemaker when you get in the room and everything will be fine. Which brings us to our next topic…

Magnets!

Magnets Rule number one: MAGNETS ARE NOT MAGIC! They do NOT fix everything. They do NOT magically make your pacemaker or ICD lovely and compatible with any situation. You do NOT always have to put a magnet on every implantable device just because the patient is going to surgery. You DO always want a magnet available

Magnets – What do they do? Generally will put a pacemaker into asynchronous mode Not always the same response, even for the same company May be high rate asynchronous (80-100), asynchronous with programmed rate or asynchronous low rate (60-100) Generally will suspend the arrhythmia detection on an ICD Will NOT switch the pacemaker function to asynchronous If you’re expecting electrical interference for a patient with an ICD-pacemaker you should have the rep reprogram the device to turn off arrhythmia detection and put the pacemaker into asynchronous mode

Caution Asynchronous modes are for the OR – only when you expect or see interference with the pacemaker/ICD In asynchronous modes YOU are the sensor Never leave a patient in asynchronous mode Risk of R-on-T → VT/VF If you turn off arrhythmia detection in an ICD, you must have an external defibrillator immediately available

Program these numbers into your phone Magnets Notice that these slides said what magnets generally do. Magnet response depends on brand, type of device, whether magnet mode is turned on, battery level… It’s good practice to call the manufacturer to confirm the device response to a magnet before using one. Program these numbers into your phone Biotronik: 1-800-547-0394 Boston Scientific: 1-800-227-3422 Medtronic: 1-800-633-8766 St Jude: 1-800-722-3774 These numbers are available 24/7, everyday

Asynchronous Modes AOO, DOO, and VOO are asynchronous modes They only pace They have no sense and no inhibitions “The Paris Hilton of pacing modes” It’s fun to be Paris Hilton for a little while, but no one wants to be Paris Hilton forever (as evidenced by her current irrelevance) Also all the OO modes = 007 → License to Kill (DOO, VOO, AOO)

What do you need to know Preoperatively? Type of device ICD - history of shock, lowest HR for shock delivery, resynchronization therapy? Brand/model Does the company have a rep available at your facility? Who can interrogate the device? Will someone be able to reprogram the device if a magnet is used? Why does the patient have it? When was it placed? Underlying rhythm/pacemaker dependent? When was it last interrogated? What does the magnet do? Confirm that battery life > 3 months If the patient does not have a report in the chart with all of this information, call the device company! It will only take 5 minutes and they will gladly help you and provide all this information.

Other Pre-op Considerations What type of surgery is the patient having? Do you anticipate electromagnetic interference (EMI) from cautery or any other source? Monopolar vs bipolar cautery Placement of grounding pad Patient positioning Location of the surgery EMI is much more likely if within 15 cm of the pacemaker/ICD generator Type of surgery EMI is more common with certain procedures such as ECT, radiofrequency ablation, lithotripsy…

What do you do Post-op? Interrogate the device If you have used the magnet or reprogrammed the device pre-op/intra-op If the pt had significant perioperative events i.e. cardiac arrest, anything that required temporary pacing, CPR If the pt had hemodynamically challenging surgery i.e. large vascular surgery, any surgery that led to or may lead to large shifts in hemodynamic status If the pt had cardiothoracic surgery If the patient underwent any surgery with high risk of EMI Always make sure you pass on in report everything you know about the patient’s device

What if the pacemaker stops working?

Take Home Quick Facts Pacemakers can only accelerate the heart. They never slow it down. Never leave a patient in asynchronous mode. Magnets do NOT fix everything! Always make sure you know what a magnet will do to a device before using it. Make sure you know everything you need to know about a device before going to the OR Type Brand/model Why the patient has it Underlying rhythm/pacemaker dependent? What does the magnet do? ICD history of shock Battery life > 3 months

Pacemaker Code Quick Reference What is it? Who gets it? AOO Atrial pace, no sense, no inhibition (Paris Hilton) Sick sinus syndrome (SSS) with intact conduction in OR with Bovie interference AAI Atrial pace, atrial sense, inhibited by atrium SSS with intact conduction system VOO Ventricular pace, no sense, no inhibition 3rd degree heart block in OR with afib VVI Ventricular pace, ventricular sense, inhibited by ventricle 3rd degree heart block with a fib DOO Dual pace, no sense, no inhibition 3rd degree heart block in OR DVI Dual pace, ventricular sense, inhibited by ventricle 3rd degree heart block with SVT DDD Dual pace, dual sense, inhibited by either atrium or ventricle 3rd degree heart block

References Barash, P., Cullen B. & Stoelting R., Cahalan, M., & Stock, M., (2013) (7th ed.). Clinical anesthesia. Philadelphia: J.B. Lippincott Appendix 2 Kirk, M. (2005) Basic principles of pacing. Nagelhout, J., & Plaus, K.,(2014). Nurse anesthesia (5th ed.). St. Louis: Elsevier Sanders. Wallace, A. (2008). Pacemakers for anesthesiologists made incredibly simple. Obtained from http://cardiacengineering.com/