Inappropriate shocks by subcutaneous implantable cardioverter-defibrillator due to T- wave oversensing in hyperkalemia leading to ventricular fibrillation 

Slides:



Advertisements
Similar presentations
Implantation of the subcutaneous implantable cardioverter-defibrillator with retroperitoneal generator placement in a child with hypoplastic left heart.
Advertisements

Subcutaneous implantable cardioverter-defibrillator placement in a patient with a preexisting transvenous implantable cardioverter-defibrillator  Mohammad-Ali.
Inhibition of pacing in a dependent patient with an implantable cardioverter-defibrillator and a left ventricular assist device  Michele Murphy, MD, Timothy.
Volume 10, Issue 1, Pages (January 2013)
Ellis Rochelson, MD, Lynn Nappo, RN, Robert H. Pass, MD 
Inhibition of pacing in a dependent patient with an implantable cardioverter-defibrillator and a left ventricular assist device  Michele Murphy, MD, Timothy.
Erroneous shock by an AED: Importance of obtaining AED tracing to prevent inappropriate ICD implantation  Brian J. Cross, MD, Mark S. Link, MD, FHRS 
Swimming pool saline chlorination units and implantable cardiac devices: A source for potentially fatal electromagnetic interference  John Wight, BS,
Inappropriate shock from delayed T-wave oversensing by a subcutaneous implantable cardioverter-defibrillator after septal myectomy for hypertrophic cardiomyopathy 
Recurrent commotio cordis: Déjà vu
Malignant transformation of a chronically infected implantable cardioverter-defibrillator pocket  Donna Kang, MD, Khuyen Do, MD, Jonathan Nattiv, MD,
Spectrum of cardiac manifestations from aconitine poisoning
Successful management of wound dehiscence after implantation of a subcutaneous implantable cardioverter-defibrillator without device removal  Mitsuhiro.
Breast tissue expanders and implantable cardioverter-defibrillator: An unusual interaction  Malik Muhammad Khurram Sher Khan, MD, Malik Muhammad Humayun.
Unusual case of late dislodgment of a superior vena cava coil
Is it bradycardia or something else causing symptoms?
Quinidine effective for the management of ventricular and atrial arrhythmias associated with Brugada syndrome  Laura Halperin, BSc, Greg Mellor, MD, Mario.
T-wave oversensing during drug challenge test after subcutaneous implantable cardioverter-defibrillator implantation in a patient with Brugada syndrome 
Use of topical lidocaine in eliminating mechanically stimulated ventricular fibrillation in a patient with short QT syndrome  Maria J. Farag, BS, Joseph.
Inappropriate defibrillator shock during gynecologic electrosurgery
Anne Barnett, PA-C, Lee Eckhardt, MD, FHRS, Miguel A. Leal, MD, FHRS 
Respiratory rate trending as a cause for atrial lead noise: A first report in an implantable cardioverter-defibrillator patient  Isla McClelland, MD,
Recurrent idiopathic polymorphic ventricular tachycardia/ventricular fibrillation successfully treated by cardiac sympathetic denervation  Faisal Matto,
Successful detection of a high-energy electrical short circuit and a “rescue” shock using a novel automatic shocking-vector adjustment algorithm  Masahiro.
Repeated molecular genetic analysis in Brugada syndrome revealed a novel disease- associated large deletion in the SCN5A gene  Anders Krogh Broendberg,
A rare case of acute myocardial infarction during extraction of a septally placed implantable cardioverter-defibrillator lead  Eric Wierda, MD, LLM, Astrid.
T-wave oversensing from postural changes: A rare cause of inappropriate shock from a subcutaneous defibrillator  Muhammad R. Afzal, MD, Auroa Badin, MD,
Failure of ICD therapy in lethal arrhythmogenic right ventricular cardiomyopathy type 5 caused by the TMEM43 p.Ser358Leu mutation  Kasper Aalbæk Kjærgaard,
Low room temperature can trigger ventricular fibrillation in J wave syndromes  Masaru Yamaki, MD, Nobuyuki Sato, MD, PhD, Rina Imanishi, MD, Hirotsuka.
Oral quinine sulfate for the treatment of electrical storm and prevention of recurrent shocks in Brugada syndrome after failed cilostazol therapy  Jayaprakash.
Repeat inappropriate defibrillator discharges following defibrillator implantation. What is the mechanism and treatment?  Jeremy W. Docekal, MD, Mark.
Complete congenital heart block: A case of multilevel block
Intravenous sotalol for conversion of atrial flutter in infants
Subcutaneous implantable cardioverter-defibrillator placement in a patient with a preexisting transvenous implantable cardioverter-defibrillator  Mohammad-Ali.
Inappropriate shocks in a patient with a subcutaneous implantable cardioverter- defibrillator  Sana M. Al-Khatib, MD, MHS, FHRS, Sasmrita Belbase, NP,
Appropriate use of genetics in a young patient with atrioventricular block and family history of sudden cardiac death  Johnni Rudbeck-Resdal, MD, Jens.
Air entrapment causing early inappropriate shocks in a patient with a subcutaneous cardioverter-defibrillator  Sing-Chien Yap, MD, PhD, Rohit E. Bhagwandien,
Oversensing of an unexpected atrial flutter
Vagally mediated ventricular arrhythmia in Brugada syndrome
Inappropriate subcutaneous implantable cardioverter-defibrillator therapy due to R-wave amplitude variation: Another challenge in device management  Syeda.
Daniel W. Nelson, BS, Caroline Vloka, BA, Jule Wetherbee, MD 
Progressive electrical remodeling in apical hypertrophic cardiomyopathy leading to implantable cardioverter-defibrillator sensing failure during ventricular.
Mitral valve repair results in suppression of ventricular arrhythmias and normalization of repolarization abnormalities in mitral valve prolapse  Wael.
Complexity of ranolazine and phenytoin use in an infant with long QT syndrome type 3  Reina Bianca Tan, MD, Sujata Chakravarti, MD, Melissa Busovsky-McNeal,
Successful implantation of a subcutaneous cardiac defibrillator in a patient with a preexisting deep brain stimulator  Yousef Bader, MD, Jonathan Weinstock,
An unusual cause of HV prolongation
Elizabeth V. Saarel, MD, FHRS, Susan P. Etheridge, MD, FHRS, David G
Unstable accelerated idioventricular rhythm in a neonate with congenital heart disease  Jonathon Hagel, BMSc, MB, BCH, BAO, Carolina Escudero, BSc, MSc,
Congenital heart disease confounding the diagnosis of arrhythmogenic right ventricular cardiomyopathy  Omid Kiamanesh, MD, Maryam Farhan, MD, Shubhayan.
Changing place, changing future: Repositioning a subcutaneous implantable cardioverter-defibrillator can resolve inappropriate shocks secondary to myopotential.
Subcutaneous implantable cardioverter-defibrillator implantation in a patient with bilateral pectoral deep brain stimulators  Thor Tejada, MD, Faisal.
Different rate-dependent responses between J waves and the notches on an epicardial local electrogram in a patient with idiopathic ventricular fibrillation 
Impact of a novel algorithm designed to reduce T-wave oversensing with the subcutaneous defibrillator in a patient with type I Brugada electrocardiogram 
Abdominal implantable cardioverter-defibrillator placement in a patient requiring bilateral chest radiation therapy  Ankur A. Karnik, MD, FHRS, CCDS,
Serious case of the hiccups
The runaway defibrillator…A case of an implantable cardioverter-defibrillator that failed communication and deactivation with a magnet  Mahmoud Assaad,
Intermittent failure to capture: What is the mechanism?
Right ventricularly paced right bundle–type pattern on ECG: Does this preclude upgrading to biventricular pacing?  Adrian H. Shandling, MD, FACC, Gregory.
Unusual severe hemodynamic failure associated with standard dose of intravenous flecainide for pharmacological cardioversion of atrial fibrillation  Aref.
Nothing inside the heart – Combining epicardial pacing with the S-ICD
Shock-induced right ventricular pacing failure caused by a short circuit: Uncommon but life-threatening complication of the Riata lead  Itsuro Morishima,
Implantation of the subcutaneous implantable cardioverter-defibrillator with retroperitoneal generator placement in a child with hypoplastic left heart.
Unusual fracture in a Durata lead with shock coil fragmentation and cable externalization  Toshiaki Sato, MD, Kyoko Soejima, MD, Hideaki Yoshino, MD,
Raja Zaghlol, MD, Rama Hritani, MD, Susan O’Donoghue, MD 
Nanostim leadless pacemaker system: A longer waiting period after active fixation may reduce unnecessary repositioning  Hiro Kawata, MD, PhD, Pranav M.
Philip M. Chang, MD, FHRS, CEPS, Rahul N. Doshi, MD, FHRS, FACC 
Use of topical lidocaine in eliminating mechanically stimulated ventricular fibrillation in a patient with short QT syndrome  Maria J. Farag, BS, Joseph.
Ventricular tachycardia slower than the rate cut-off of a subcutaneous cardiac defibrillator sensed and successfully treated as a result of oversensing 
Mobile subcutaneous implantable cardioverter-defibrillator leads to oversensing and inappropriate shocks  Omid Kiamanesh, MD, Jacob M. Larsen, MD, PhD,
Substernal subcutaneous implantable cardioverter-defibrillator lead placement for the management of inappropriate shocks  Khuyen Do, MD, Chin C. Lee,
Presentation transcript:

Inappropriate shocks by subcutaneous implantable cardioverter-defibrillator due to T- wave oversensing in hyperkalemia leading to ventricular fibrillation  Omid Kiamanesh, MD, Deirdre O’Neill, MD, Soori Sivakumaran, MD, FRCPC, Shane Kimber, MD, FRCPC  HeartRhythm Case Reports  Volume 1, Issue 4, Pages 257-259 (July 2015) DOI: 10.1016/j.hrcr.2015.04.007 Copyright © 2015 Heart Rhythm Society Terms and Conditions

Figure 1 Surface electrocardiogram from the subcutaneous implantable cardioverter-defibrillator demonstrating appropriate QRS-T complex discrimination during implantation and normokalemia. HeartRhythm Case Reports 2015 1, 257-259DOI: (10.1016/j.hrcr.2015.04.007) Copyright © 2015 Heart Rhythm Society Terms and Conditions

Figure 2 Surface electrocardiogram from the subcutaneous implantable cardioverter-defibrillator demonstrating inappropriate shocks due to T-wave oversensing in the setting of hyperkalemia (serum potassium 7.0 mmol/L), leading to sustained ventricular fibrillation requiring 4 shocks prior to termination. HeartRhythm Case Reports 2015 1, 257-259DOI: (10.1016/j.hrcr.2015.04.007) Copyright © 2015 Heart Rhythm Society Terms and Conditions