Physiological Assessment of Coronary Artery Disease FFR/IFR

Slides:



Advertisements
Similar presentations
Physiology of Coronary Blood Flow
Advertisements

FFR & IVUS PRIOR TO REVASCULARISATION Journal review Dr. Sony Manuel M Senior Resident MCH Kozhikode.
FFR & IVUS PRIOR TO REVASCULARISATION Journal review Dr.Sony Manuel M Senior Resident MCH Kozhikode.
Coronary stenting: the appropriate use of FFR Morton J. Kern, MD Professor of Medicine Chief of Cardiology LBVA Associate Chief Cardiology University California.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
Pitfalls & Practical Tips
FRACTIONAL FLOW RESERVE versus ANGIOGRAPHY
To stent or not to stent Clinical Utility of Fractional Flow Reserve.
CORONARY CIRCULATION DR. Eman El Eter.
CURRENT STATUS OF STRESS TESTING JOHN HAMATY D.O..
Myocardial Ischemia, Injury, and Infarction
Ischemic heart disease
Diagnostic Stress Testing
1 Dr. Zahoor Ali Shaikh. 2 CORONARY ARTERY DISEASE (CAD)  CAD is most common form of heart disease and causes premature death.  In UK, 1 in 3 men and.
CORONARY PRESSURE MEASURENT AND FRACTIONAL FLOW RESERVE
DEFER STUDY: 5-YEAR FOLLOW-UP A Multicenter Randomized Study
FFR Going Beyond Angiography
PRIMARY Results of ADVISE ADenosine Vasodilation Independent Stenosis Evaluation Dr Justin Davies MD, PhD Imperial College London on behalf of the ADVISE.
CORONARY CIRCULATION DR. Eman El Eter. Coronary Arteries The major vessels of the coronary circulation are: 1- left main coronary that divides into left.
Concept and practical set-up of CFR, FFR, IMR
FFR in specific circumstances Zsolt Piróth MD Gottsegen György Hungarian Institute of Cardiology.
Tips and Pitfalls in Measurement of FFR during Bifurcation Stenting Nanjing first hospital Nanjing cardiovascular hospital Yefei Chenshaoliang Zhangjunjie.
How I do CMR Myocardial Perfusion imaging SCMR Website 2006 Christopher Klassen MD, PHD University of Florida Health Science Center Dr. Norbert Wilke This.
1 Arterial Lines Set Up & Monitoring Union Hospital Emergency Department.
Chapter 16 Assessment of Hemodynamic Pressures
PWV & PWA Parameter Extraction / Transfer Function.
Baisc Concept and Technique of FFR FuWai Hospital JieQian.
Pressure Wire Evaluation of the Left Main Stem Dr Phil MacCarthy Consultant Cardiologist King’s Cardiac Centre Left Main 5+ at AA2007, Jan 24 th, 2007.
Pathophysiology of the coronary circulation: role of FFR Giuseppe Biondi Zoccai University of Modena and Reggio Emilia, Modena, Italy
Adult Echocardiography Lecture 10 Coronary Anatomy
TAHAR EL KANDOUSSI, SARA ECHERKI, NAWAL DOGHMI, MOHAMED CHERTI. SEcurite de l’Echocardiographie de stress : plutôt l’effort. Cardiology B Department, Ibn.
Afsane mohammadi,MD Interventional cardiologist.  The presence of inducible ischemia is an important risk factor for adverse outcome.the more inducible.
Insulin Improves Myocardial Blood Flow in Patients with Type 2 Diabetes and Coronary Artery Disease Riikka Lautamäki, K.E. Juhani Airaksinen, Marko Seppänen,
Influence of a Pressure Gradient Distal to Implanted Bare-Metal Stent on In-Stent Restenosis After Percutaneous Coronary Intervention Lisette Okkels Jensen,
Date of download: 6/28/2016 Copyright © The American College of Cardiology. All rights reserved. From: From Research to Clinical Practice: Current Role.
Date of download: 7/7/2016 Copyright © The American College of Cardiology. All rights reserved. From: Diagnostic Performance of Noninvasive Fractional.
End points in PTCA trials. A successful angioplasty is defined as the reduction of a minimum stenosis diameter to
Date of download: 7/9/2016 Copyright © The American College of Cardiology. All rights reserved. From: Development and Validation of a New Adenosine-Independent.
J Am Coll Cardiol 2008;52:636–43 Comprehensive Assessment of Coronary Artery Stenoses Computed Tomography Coronary Angiography Versus Conventional Coronary.
Date of download: 7/10/2016 Copyright © The American College of Cardiology. All rights reserved. From: Echocardiography for Percutaneous Heart Pumps J.
Date of download: 9/17/2016 Copyright © The American College of Cardiology. All rights reserved. From: Does the Instantaneous Wave-Free Ratio Approximate.
Simplifying Serial Lesion Assessment
Special circulations, Coronary, Pulmonary…
ISCHEMIC HEART DISEASE
FFR DECISION MAKING DURING DIAGNOSTIC PROCEDURES
Invasive Assessment of Coronary Artery Disease
Use of fractional flow reserve in patients with coronary artery disease: The right choice for the right outcome  Jae Yoon Park, MD, Amir Lerman, MD, Joerg.
Physiologic Lesion Assessment: Advantages and Pitfalls
Multi Modality Approach to Diagnosis of Ischemia in Post CABG Cases
Ischemic Heart Disease
Physiological Assessment of Coronary Artery Disease
How I do CMR Myocardial Perfusion imaging
Solved & Unsolved Issues
ADenosine Vasodilator Independent Stenosis Evaluation II
The Winking Saphenous Vein Graft: Acute Aorto-Vein Graft Anastomotic Torsional Kink causing Dynamic Systolic Compression Complicating Vein Graft PCI Dr.
9:00 AM-9:05 AM, Tuesday, Oct. 31; Room 201/203
Renal CTA: Can We Determine Who Will Benefit from RAS
Left Anterior Descending Artery Myocardial Bridging
Heart Rate, Life Expectancy and the Cardiovascular System: Therapeutic Considerations Cardiology 2015;132: DOI: / Fig. 1. Semilogarithmic.
Intensive Observation Unit Careggi University Hospital, Firenze Italy
Fractional Flow Reserve Workshop
Circ Cardiovasc Imaging
Alexander Liu et al. JACC 2018;71:
Intravascular imaging and physiologic lesion assessment to define critical coronary stenoses  Luis Gruberg, MD, Gary S Mintz, MD, Lowell F Satler, MD,
Role of CT Coronary Angiogram in pre-renal transplant evaluation
Correlation between endothelial function and hypertension
Figure 1 Typical case example
ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions J. Mehilli, MD Deutsches Herzzentrum Technische.
FFR guided deferral of PCI in patients with ACS and stable coronary artery disease (SCAD). FFR guided deferral of PCI in patients with ACS and stable coronary.
Presentation transcript:

Physiological Assessment of Coronary Artery Disease FFR/IFR DR SURESH S Senior resident MCH CALICUT

Structure & Function of the Coronary circulation Epicardial arteries (>400 μm in diameter) Serve a conduit artery function, Coronary resistance Resistance arteries (100 to 400 μm), Arterioles (>100 μm),. Capillary density Average intercapillary distance of 17 μ m

The Coronary blood flow Oxygen extraction at rest is around 70 % Increase in oxygen demand Is met by increase in coronary blood flow Dilation of microcirculation Coronary blood flow At rest is 250ml/min Stress upto 5 times

Myocardial ischemia results from… Microcirculation dysfunction Epicardial stenosis >50 Coronary angiography Fails to detect perfectly 70 %

Limitations (CAG) Highly subjective Intermediately severe luminal narrowing (40% -70%) cannot be accurately determined Identification of normal and diseased vessel segments is complicated by diffuse disease Artifacts of contrast streaming Image foreshortening Overlapping vessels

Coronary flow reserve

Coronary flow reserve Normal CFR Abnormal CFR Early studies 3.5 to 5 CAD Risk factors 2.70 Abnormal CFR Microvascular disease. Epicardial ischemic threshold <2.0.

rCFR Ratio Normal range 0.8 to 1.0 Limited role in MVD maximal flow in a coronary artery with stenosis (QS) to maximal flow in a normal coronary artery without a stenosis Normal range 0.8 to 1.0 Limited role in MVD Assumes that the microvascular circulatory response is uniformly distributed among the myocardial beds Is of no value In with myocardial infarction left ventricular regional dysfunction Asymmetric hypertrophy

FFR Normal value 1 An FFR value of 0.6 means the maximum myocardial flow across the stenosis is only 60% of what it should be without the stenosis An FFR <0.75 is associated with inducible ischemia (specificity, 100%), An FFR a value >0.80 indicates absence of inducible ischemia in the majority of patients (sensitivity, 90%).

Figure 2 Typical example of simultaneous aortic pressure (Pa) and distal coronary pressure (Pd) recordings at rest and during maximal steady state hyperaemia as induced by an intravenous infusion of adenosine. Soon after starting the infusion, the decrease in distal pressure is preceded by a transient increase in aortic pressure.

FFR - advantages Human studies did not show significant changes in FFR with changes in heart rate, blood pressure, contractility. FFR has a high reproducibility Low intra-individual variability FFR, unlike CFR, is independent of gender and CAD risk factors It varies less with common doses of adenosine than does CFR

FFR- TECHNIQUE Catheter Diagnostic catheters can not be used to measure FFR - pressure measurements can be inaccurate & the wire manipulation is met with friction due to smaller internal diameters compared to guide catheters. The main advantage of using guide catheters is that PCI is immediately possible if required. Guide catheter with Side holes should not be used It can create a false gradient between the side holes & the tip of the guide catheter creating a false Positive FFR. Pharmacological vasodilatory agents may be flushed into the aorta instead of the coronary artery.

Pressure Monitoring Guide Wire 0.014” 3 cm

Pressure Measurement Step 1: Zero the Pressure System to the Atmosphere Step 2: Insert the Pressure Sensor Guide Wire Into the Guide and Equalize the 2 Pressures Step 3: Advance the Pressure Wire Sensor Distal to the Region of Interest Step 4: Induce Maximal Hyperemia Step 5: Wire Pullback to Check for Signal Drift A standard fluid-filled pressure transducer is used for aortic pressure recordings. Special attention should be paid to purging the system of air, zeroing of the catheter tubing system, and obtaining an optimal aortic pressure waveform. The guiding catheter should be frequently flushed with normal saline (at least every 10 minutes). Because contrast medium may subtly dampen the catheter pressure waveform, all contrast medium should be flushed from the catheter during the zeroing steps before pressure measurement. If any pressure damping or ventricularization of the catheter pressure waveform is observed, the guiding catheter should be gently disengaged from the ostium, taking care not to alter the position of the pressure wire in the distal vessel. Zero the sensor of the pressure wire ex vivo, following the instructions of the manufacturer.

Key Points of Performance of Fractional Flow Reserve (FFR) Measurements Patient preparation • Routinely obtain informed consent for FFR prior to every diagnostic coronary angiogram. • Medication for FFR identical to PCI. • Use a large calibre access in the femoral or cubital vein for peripheral adenosine application. • Beta-blockers do not need to be interrupted. • Caffeine >1 hour prior to FFR measurement has no clinically-relevant effect. • Theophylline should be interrupted 12 hours prior to FFR.

Catheter selection and positioning • Use guiding catheters (at least 5F) without side holes. • Ascertain coaxial catheter position in the coronary ostium. • Disengage guiding catheter from ostium for pressure calibration, equalisation and recording of pd/pa if there are doubts about the catheter potentially obstructing the ostium.

Calibration • Before starting FFR measurement, ensure proper zeroing of the aortic pressure. • Flush the FFR wire, lay flat when connecting/calibrating and do not move. • Before equalisation of pressures, advance the FFR wire into the coronary artery until the pressure sensor is positioned precisely at the end of the guide catheter. • Before equalisation of pressures, flush the guide catheter in order to remove the viscous contrast agent. • Before equalisation of pressures, remove the introducer and close the haemostatic valve. • Pressure curves are typically averaged across three-to-five heartbeats. Therefore, pressure equalisation requires some time, and no artefacts should occur during that time

Positioning of the FFR wire or microcatheter • Pressure sensor should be positioned in the main vessel directly downstream the most distal leasion. • A second wire, in addition to the pressure sensor, could result in artefacts, and should therefore be avoided. • Be careful of artefacts: the sensor could interact with the vessel wall, especially in cases of a narrow vessel calibre or severe tortuosity. • Viscous contrast agent in the coronary artery can affect the gradient pd/pa. • In the case of a resting gradient <0.80, measurement under hyperaemia is not necessarily required in order to make a clinical decision.

Hyperaemia • Prior to advancement of the FFR wire/FFR microcatheter, administer intracoronary nitrates in order to prevent spasms in epicardial vessels • Medication for hyperaemia: • Intravenous: Adenosine 140 μg/kg/min Regadenoson 400 μg undiluted. • Intracoronary: Adenosine (e.g. 40 μg intracoronary for the right coronary artery and 80 μg intracoronary for the left coronary artery) Papaverine (e.g. 8 mg for the right coronary artery and 12 mg for the left coronary artery) • In the case of measurement results in the borderline area, an increased dose of adenosine is possible (while not supported by evidence). Intravenous doses >180 μg/kg/min can reduce coronary perfusion, and are therefore, not recommended.

Registration and evaluation • FFR value is the lowest ratio pd/pa registered during the steady state. • In case of intravenous adenosine administrations, pressure values can fall to a minimum before reaching a steady state. These values should not be interpreted as FFR values. • Artefacts must be carefully observed and excluded. • Ectopic beats can cause false-low FFR values, which must be excluded. • Values measured under atrioventricular-block/bradycardia must be classified as “not evaluable”.

Key Points of Special Clinical Situations Aorto-ostial stenoses • Intravenous administration of adenosine is preferred. • Withdraw the guide catheter from the ostium for pressure equalisation and FFR measurement. Left main coronary artery stenosis • FFR measurement in downstream vessels without stenosis, optimally both in the left circumflex coronary artery and left anterior descending coronary artery. Serial stenoses • Can only be evaluated jointly. • Distally-measured value represents the combined effect of both lesions. • Values measured in between two stenoses are unreliable.

Acute coronary syndromes • In the case of STEMI, FFR measurement in the infarcted vessel is neither reasonable nor possible. In the case of NSTEMI, in the absence of a relevant thrombus load, lesions can be assessed using FFR. FFR during and after PCI • There is no established target value for FFR after PCI. • In the case of bifurcation lesion PCI, revascularisation of the side branch is not necessary if FFR is >0.80 in the side branch

Limitations of Fractional Flow Reserve Measurements Microvascular dysfunction, previous myocardial infarction Left ventricular hypertrophy diabetic microangiopathy

certain patient groups were not included or tested in the randomised FFR studies. FAME studies, (excluded) left main coronary artery stenosis, recent history of STEMI history of bypass surgery impaired left ventricular (LV) systolic function (LV ejection fraction <30 %) left ventricular hypertrophy (>13 mm) there are currently no randomised, controlled outcome studies to validate FFR.

Instantaneous wave-free ratio (iFR) reduce the procedural time, improve cost efficiencies as well as improve patient comfort iFR is founded on the basis that there is a certain period in each cardiac cycle during which resistance at rest is stable (the wave-free period). During this phase the ratio of the proximal and distal pressures are proportional to coronary flow

Identification of wave-free period Fully automated algorithms Identification of naturally low resistance period Uses pressure only Radical solution, be identification of the wave-free period. Sen S, Escaned J, Davies JE et al. JACC (in press 2011) Davies JE et al. Circulation 2006;113:1767-1778 Davies JE et al. Circulation 2011;124:1565-1572

Instantaneouswave-free ratio (iFR)

80 - 85% concordance between iFR and FFR when iFR = 0.89

trials

iFR was non inferior to FFR with respect MACE at 12 months (dead, non fatal MI, unplanned revascularization)

Thank you

Back up slides

49 centers 19 countries