E VERY L IFE H AS A P URPOSE… Ultrasonic Gas Leak Detection E VERY L IFE H AS A P URPOSE…

Slides:



Advertisements
Similar presentations
Electrical & Instrument Construction Department
Advertisements

Atmosphere 2009 in Brussels Replacing F-gases with ammonia or why ammonia was never replaced by synthetic refrigerants…
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
The Care and Feeding of Silane Art Garcia FM Global March 23, 2006.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Sensor Operating Theory
J. Amdahl,, NTNU Dept, Marine Technology Beregning av ulykkeslaster for offshore stålkonstruksjoner – NFS Accidental Fires Design criteria.
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
Strategic Corrosion Monitoring in Topside Applications Tom Swihart GE Measurement & Control Solutions.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
Sandra Rodiño Palacios – Statoil ASA
VSE Corporation Proprietary Information
FIRE Safety Solutions Dr. Pulak De FIGHT FIRE WITH KNOWLEDGE.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
Learning from a recent incident
Standards Certification Education & Training Publishing Conferences & Exhibits Fixed Ultrasonic Gas Leak Detection Edward Naranjo Emerson Process Management,
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
E VERY L IFE H AS A P URPOSE… Z Gard ® Family of Gas Detection Products.
etec.dk etec.dk electronic technical engineering & construction ultra low noise hydrophone charge amplifiers PD1102 Pinger Detector Amplifier The ultimate.
Ultrasound Technology and Compressed Air Audits Ultrasound Technology and Compressed Air Audits.
Low-GWP Alternative for Small Rigid PU Foam Enterprises Conversion Demonstration from HCFC-141b-based to Cyclopentane-based Pre-blended Polyol in the Manufacture.
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
C O 2 CALIBRATION Sathish TEST 1 (200 SCCM ) Synthetic air 350 ppm Test gas 10 min.
© ABB-EWEC 2006 ATHENS /03/06 EWEC 2006 Athens The Challenges of Offshore Power System Construction Peter Jones Lars Stendius ABB.
ABB LCC ECS - 1 © 2004  Industrial IT Power Management System Scope & Value Proposition Lead Competence Center Electrical Control Systems.
1 Product Line Review. 2 3 RS Series  UV & UV / WBIR  Alarm Relay  Analog  Safe Area use only  Fire Sentry still sells a lot of these!
Hydrogen R&D system HAZOP and failure analysis Yury Ivanyushenkov, Elwyn Baynham, Tom Bradshaw, Mike Courthold, Matthew Hills and Tony Jones.
PRESENTATION BY ATIF DAR ULTRASONIC SENSORS.. CONTENTS PAGE Page 1 – Homepage Page 3 – Description of Ultrasonic Sensor. Page 4 – How the Ultrasonic Sensor.
Gas Sensor and Transmitter
E VERY L IFE H AS A P URPOSE… ULTIMA ® OPIR-5 Open Path Gas Detector E VERY L IFE H AS A P URPOSE…
Standards Certification Education & Training Publishing Conferences & Exhibits Technical and Commercial Feasibility of the Third Generation LDAR (LDAR3)
Flow Group Smart Wireless. [File Name or Event] Emerson Confidential 27-Jun-01, Slide 2 Flow Group Wireless Offerings.
Real-Time Prognostic Analysis Systems: Monitoring and Damage Mitigation David Greene [GRDI] Tristan Seroff [GRDI] Preston Johnson [NI] August 7 th, 2013.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Patrick Thornton, SNS/FPE June 9, 2008
GAS DETECTOR BY : SELAMAT SURIYADI.
Dailies, Weeklies, Monthlies, PSM Maintenance - Simplify IT If you’d like to reach SCS Engineers, Tracer Environmental Division please contact us at:
WELCOME TO Gas Tester Training O2, LEL Monitoring
GasGard® XL Monitor.
Pro-Science 4 th International Conference of Hydrogen Safety, September 12-14, 2011, SAN FRANCISCO, USA EXPERIMENTAL STUDY OF IGNITED UNSTEADY HYDROGEN.
Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor
Joint ILC/CLIC Safety document ► Incentive for this document:  Share effort to define a coherent safety protocol for future linear colliders.  Insure.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
The Theory of Near Light Scatter
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Sandra Nilsen et. al Determination of Hazardous Zones Case study: Generic Hydrogen Refuelling Station.
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Gary Rees UE Systems Europe Ultrasound for Preventative and Predictive maintenance.
Bi-Weekly Safety Meeting November 29, The days of using canaries in mines as primitive gas detectors are long gone..they've been replaced by fixed.
Ultrasonic Early Kick Detection (EKD) System
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Ultrasonic High-Pressure Full-Bore Return Flow Meter IBJ Technology Ingenieurbüro Jäger 1 Ultrasonic Mud Flow Meter.
Extrima ex-certified Hydrogen Leak detector
14 August 2017 Presenter Rod Dickson Event CSA Conference.
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Magnetostrictive Liquid Level Transmitter
LOP Flare Pilot Outage Shell Martinez Refinery 7/6/18
Leak Detection in half the time
169 South Main Street, New City, NY 10956
Gas Leak Monitoring by Ultrasound
Presentation transcript:

E VERY L IFE H AS A P URPOSE… Ultrasonic Gas Leak Detection E VERY L IFE H AS A P URPOSE…

Increase detection reliability and reduce risk as ultrasonic gas leak detection provides instant and verifiable detection of gas leaks. The ultrasonic technology will detect pressurised gas leaks instantly regardless of gas dilution and ever changing weather conditions found on most on- and offshore installations in the petrochemical industry. Ultrasonic Gas Leak Detection

Application Area Applications for Ultrasonic Gas Leak Detectors: Instant detection of flammable gas leaks Fixed installations Explosion hazardous areas Pressurized gas installations Outdoor or semi outdoor ventilated areas Electrical connection to DCS system or fire and gas panel

WHAT is Relevant to Detect? In plant installations with pressurized flammable gases, it is relevant to detect gas leaks that can accumulate into a potentially explosive gas cloud. WHEN is it Relevant to Detect? As fast as possible - to prevent build-up of dangerous concentrations. Accumulation of gas can lead to explosions. Ultrasonic Gas Leak Detection

Three main factors determine if a hydrocarbon gas leak can create a catastrophic explosion: 1) Oxygen 2) Ignition Source 3) Gas Concentration The amount of gas released over time from a gas leak is known as the LEAK RATE and has units of kg/s. What Creates an Explosion?

Important Parameters to Know in a Gas Leak Detection Situation: Leak rate (kg/s): Detection related to the leak rate, makes it possible to introduce a performance standard for the gas leak detection system. Example: Gas leaks with a leak rate of 0.1 kg/s or more must be detected. Lower Explosive Level (% LEL): A concentration measurement in a pre-defined point that may create a true picture of the nature of the gas leak. Leak Rate vs. LEL

Live Gas Leak Test on a North Sea Off-Shore Installation: Within 4-5 meters the gas concentration around the leak was below 5% LEL! None of the existing gas detection systems alarmed! The ultrasonic gas leak detector detected the leak up to 19 meters away! Leak size: 3 mm Gas pressure: 55 bar (808 psi) Leak rate: 0.06 kg/s Real Gas Leak Test with Ultrasonic Detectors

Main Characteristics: Instant acoustic gas leak detection Detects gas leaks at a leak rate of 0.1 kg/s Detection radius up to 20 meters away Unaffected by changing wind direction and fast dilution of gas Minimal maintenance and calibration requirements Ultrasonic Gas Leak Detection

Acoustics and Gas Leaks Gas molecules travel from high pressure to low pressure Hissing sound Acceleration of gas produces white noise, which consists of both audible and ultrasonic sound components Acoustic detectors filter the audible range – responding to sound in frequencies from 25 kHz to approximately 50 kHz – far higher than frequencies human hearing can detect Ultrasonic leak noise is proportional to the leak rate

The detection range of an ultrasonic gas leak detector depends on these variables: Leak size Pressure Ultrasonic background noise Leak size and gas pressure determine the acoustical ultrasonic noise level generated from the leak. Leak Detection Range

Directional Characteristics

Limitations Traditional Technologies Can Be Problematic –Changing wind directions –Gas dilution –Direction of the leak Acoustic Technology Limitations –Low pressure (normal application of 10 bar and higher) –High background noise ( > 90 dB) – although rare

UltraSonic EX-5 Gas Leak Detector Main Features: Senssonic integrated acoustic self-test Standard 4-20 mA analog output RS 485 serial digital communication interface Explosion-proof housing in solid 316L stainless steel for extreme environmental conditions Minimal calibration and regular maintenance Robust microphone technology to ensure long MTBF FM, CSA, C-UL, ATEX, IECEx, GOST certified for hazardous areas

UltraSonic EX-5- Test Transducer How to Ensure Failsafe Operation? Senssonic Built-In acoustic Integrity Test External loop configuration Controlled functionality and integrity test every 15 minutes No un-revealed failures between inspections 4-20 mA signal indicates any abnormalities (to 1 mA for 5s)

Installation Practice Allocation of Ultrasonic Detectors Based On: –Plant details and layout –Ultrasonic background noise mapping survey Installation of Ultrasonic Gas Leak Detectors System Commissioning, Performance Verification –Test with portable test and calibration unit –Actual leak simulation with nitrogen

Background noise mapping and detectors allocation Installation on Existing Installations

New Installations - Allocation Detectors installed at elevated position (approx. 2 m above potential leak sources) with the sensor head facing down. Avoid solid decks or big vessels blocking path between leak spots and detector. Heavy piping does not block the sound to the detector.

Commissioning, Testing, Calibration Commissioning: –1701 Portable Test and Calibration Unit –Live leak simulation of 0.1 kg/s gas leaks (using nitrogen gas) Testing and Calibration: –1701 – Traceable, calibrated test and calibration unit Gain test and field calibration if required (every 6-12 months)

Typical Applications Offshore oil and gas platforms Onshore oil and gas terminals Floating production storage and offloading vessels (FPSOs) Gas compressor and metering stations Underground gas storage facilities Downstream chemical processing plants (e.g. ethylene, methanol, ammonia, and propylene) Hydrogen storage facilities Refineries LNG/GTL trains (plants) LNG re-gasification plants Gas turbine power plants

Installations Worldwide Most Major End-Users in Oil & Gas are Implementing UltraSonic Detectors for Projects Worldwide North Sea: England, Denmark, Holland, Norway (Sleipner, Gullfaks) The Americas: USA, Canada, Trinidad & Tobago (Cannonball) Middle East: UAE, Oman (Saih Rawl, Saih Nihyada, Al-Kawther, Harweel) Far East/Central Asia: China (Bohai Bay), Malaysia (Shell Bintulu), Pakistan (Rehmat), Indonesia (Tangguh) Africa: Equatorial Guinea (Marathon ALBA), Algeria (Hassi Berkine) Caspian Sea Region: Azerbaijan (Shah Deniz), Russia (Sakhalin II), Kazakhstan (Kashagan)

For more information, visit our website Conclusions Why Ultrasonic Gas Leak Detection? Reduce risk Instant and reliable detection Unaffected by changing weather conditions Possible to pre-define safety standards and verify system performance No undetected failures: Built-in self-test function Cost effective – reduced total cost of ownership

E VERY L IFE H AS A P URPOSE… UltraSonic EX-5 Gas Leak Detection E VERY L IFE H AS A P URPOSE…