The Ideal Breathing System

Slides:



Advertisements
Similar presentations
Chapter 11 Refrigeration Cycles Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 5th edition by Yunus A. Çengel.
Advertisements

Oxygen Therapy.
INHALATION ANAESTHESIA BREATHING SYSTEMS Prepare and monitor anaesthesia in animals INHALATION ANAESTHESIA BREATHING SYSTEMS.
Gas Exchange and Pulmonary Circulation. Learning Objectives Understand diffusion and the rate of diffusion. Understand gas pressure and partial pressure,
CPAP/PSV.
Positive pressure ventilation Ventilation of the lungs single most important and most effective step in cardiopulmonary resuscitation of the compromised.
ANESTHETIC MACHINES.
Anesthesia Machine Presented by Gil Soto C.R.N.A.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 1 of 4.
Breathing Machine. Design Requirements Provide/Remove 500cc of air Rate ≈ 15 breaths per minute Ability to vary volume of air, and rate Age (years)Weight.
Paediatric breathing systems Dr. S. Parthasarathy MD., DA., DNB, MD (Acu), Dip. Diab.DCA, Dip. Software statistics PhD (physio) Mahatma Gandhi medical.
Check Valves and Manufacturer-Recommended Leak Test
Trigger/Limit/Cycle/Baseline
Scavenging System  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected to a.
Nitric Oxide Set-up for Patients on Ventilator
Initiating Positive Pressure CMV A generic approach!
1 Oxygen Administration. 2 Introduction  Oxygen is a colorless, odorless, tasteless gas that is essential for the body to function properly and to survive.
HOW TO PICK INITIAL SETTINGS FOR A MULTIPLE CHOICE TEST Mechanical Ventilation.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 4 of 4.
PART 3: Breathing Circuit
AHP300 VENTILATOR Prepared by Caesar Rondina, EMTP, SCT, EMTP, CES
Parts of the Anesthetic Machine
Nitric Oxide Set-up for Patients on Ventilator
BAG & MASK VENTILATION.
A). When the carrier gas is quickly switched to 100% nitrous oxide (B). the halothane concentration decreases to 3% within 8 to 10 seconds A new steady-state.
1 Life Products LP-6, LP 6 Plus and LP 10 Home Ventilator By Bryce Younger.
Dr. S. Parthasarathy MD., DA., DNB, MD (Acu), Dip. Diab. DCA, Dip. Software statistics PhD(physiology) Mahatma gandhi medical college and research institute,
Anesthesia Breathing Systems
Products Training.
Scavenging System A&A Pg 356  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected.
1 Omni Vent MRI by Bryce Younger by Bryce Younger.
Anesthetic Breathing Circuits
Pressure reducing valve By Dr. Ahmed Mostafa Assist. Prof. of anesthesia & I.C.U.
Non-Rebreathing System  Used for patients weighing < 7 kg  Attach the clear, plastic hose to the fresh gas inlet (this tube comes from the vaporizer.
Breathing systems and the anaesthetic machine Zsolt Molnár SZTE, AITI.
Ventilators All you need to know is….
Introduction The Universal Anaesthesia Machine (UAM) is a recently introduced low cost anaesthetic machine designed to enable safe reliable anaesthesia.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 2 of 4.
Oxygenation And Ventilation
ANAESTHESIA BREATHING CIRCUITS
Breathing systems and the anaesthetic machine Zsolt Molnár SZTE, AITI
Understanding Mapleson Circuits
PART 3: Breathing Circuit
VNTE Prep Anesthetic Review.
Anesthesia Machine Circuits
Ventilators Tuesday, 20 April 2004 Bill McCulloch.
CLINICAL ALGORITHM FOR THE MANAGEMENT OF INTUBATED PATIENTS PRESENTING WITH CHANGES VISSIBLE ON CxR Next step in the algorithm.
Carbon Dioxide Monitoring
Parts of the Anesthetic Machine A&A Pages
PART 3: Breathing Circuit
Ventilatory Modes. Volume Controlled Mandatory Breath Gas is delivered at a constant flow until the set tidal volume is reached. Pressure rises to a.
BREATHING SYSTEMS.
PRESSURE CONTROL VENTILATION
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 3 of 4.
Oxygen Therapy Aaqid Akram MBChB (2013) Clinical Education Fellow.
PART 3: Breathing System Parts
Mapleson D circuit. Note that the fresh gas inlet (FGI) is distal to the adjustable pressure-limiting (APL) valve and proximal to the patient end. (Reproduced.
Non-Rebreathing System
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
Diagram of a T piece (Mapleson E circuit)
Nonrebreathing valve at the distal end of a bag valve mask
Non-Rebreathing System
The Anaesthesia Machine
Intravenous boluses of fentanyl, 1 µg kg−1, and remifentanil, 0
Breathing Systems Tom Williams.
The effect of bi-level positive airway pressure mechanical ventilation on gas exchange during general anaesthesia  Yu G , Yang K , Baker A.B. , Young.
Preoxygenation: a comparison of three different breathing systems
Marine Biotechnology Lab
Diagram of rebreathe apparatus.
Presentation transcript:

The Ideal Breathing System Simple and safe to use Delivers the right gas mixture Allows all methods of ventilation in all age groups Efficient Pressure relief Sturdy, small and light Allows easy removal of waste gases Easy to maintain with low running costs

Breathing System Components Fresh Gas connection Patient connection Adjustable Pressure Limiting (APL) Valve Reservoir (Bag or bellows) Tubing Waste gas connection

Open, semi open, semi closed? Open is the old fashioned method of dropping ether or chloroform over a gauze or lint. Later modernised by the likes of the Schimmelbusch mask. Semi-open I classify as systems used today such as the Mapleson systems. Semi-closed and Closed systems use a CO2 absorbent so that the gases are re-circulated, the classification is defined by the amount of fresh gas flow.

‘The Mapleson Alphabet’ Semi-open Systems In the early 1950’s, Prof. WW Mapleson from University of Wales, Cardiff, classified the several breathing systems around depending on what components they contained and what position they took in the system. It is known today as ‘The Mapleson Alphabet’

The Mapleson Alphabet The F was added later to the alphabet

Semi-open Circuit Anaesthesia This is typically used for induction of the patient. It is usually a single limb system that uses an APL valve to control the pressure of the gas, and allows for waste gas to leave the system. High fresh gas flows (more than patients minute volume) are required with these systems to stop rebreathing of expired CO2.

Types of Semi-open Circuit Systems Mapleson D or Bain System Mapleson A or Magill System Mapleson A or Lack System Mapleson F or Ayres T Piece System Mapleson F with APL Valve Mapleson C Bagging System

What FGF’s are needed? A B C D E F Mapleson Systems Uses FGF SV FGF IPPV A Magill Lack Spontaneous Gen Anaesthesia 70-100 ml/kg/min Min 3 x MV B Very uncommon, not in use today C Resuscitation Bagging Min 15 lpm D Bain IPPV, Gen. Anaes 150-200 ml/kg/min E Ayres T Piece F Jackson Rees Paediatric <25 Kg 2.5 – 3 x MV Min 4 lpm

Mapleson A (Magill) System The Mapleson A or Magill system is good for spontaneous breathing patients, so the fresh gas flow can be lower. However as the APL valve is close to the patient, it is regarded by many as difficult to use.

Mapleson A (Lack) System 1976 The Mapleson A or Lack system is a modification of the Magill where the valve is moved to the machine end of the system using another length of tubing. This adds volume to the system and makes it rather heavy at the patient end.

Mapleson D (Bain) 1972 The Mapleson D or Bain System is a co-axial system where the fresh gas is delivered directly to the patient. It requires very high fresh gas flows to prevent rebreathing of CO2. It is very convenient to use, thus is very popular especially for induction, in the UK!

Mapleson F (Jackson Rees Modification) Ayres – 1937 JR - 1950 The Mapleson F or Jackson Rees modification of the Ayres T Piece is a basic system for use with very small patients. It is a big disadvantage that you cannot remove waste gases safely. Because this has a bag with an open tail, it is technically a Jackson-Rees Modification system

Mapleson F with APL Valve 1998 Intersurgical decided to modify the Jackson-Rees by using a closed tail bag and a specially modified APL valve. Now the waste gases can be removed safely from the system via the APL valve’s 30mm outlet.

Mapleson C Bagging System The Mapleson C is more than an anaesthesia system. It can be found all over the hospital for use as an emergency bagging system for resuscitation or manual ventilation using oxygen, as well as being a standard induction system in some countries.

Semi Closed Circuit Anaesthesia This type of General Anaesthesia is used mainly for maintenance of anaesthesia following induction. It can be used for induction of anaesthesia, but this is a slower process. It requires an absorber system containing a CO2 Absorbent to remove CO2 from the expired patient gases, and a high degree level of patient monitoring, especially respiratory gas monitoring to measure levels of inspired and expired CO2 and the volatile agent.

Semi Closed Anaesthesia Explained Semi Closed Anaesthesia is where the expired gases from the patient pass through a canister in the breathing system which contains a CO2 absorbent. This absorbent by an exothermic chemical reaction removes the CO2, so the patients expired gases can be rebreathed. Because of this exothermic chemical reaction, some warmth and humidity is added to the inspired gases.

Semi Closed Anaesthesia Explained Because the patients expired gases are re circulated (where the ‘circle’ comes from), this means that we do not have to add so much fresh gas to the system like an open system. So the fresh gas flow rate can be reduced to low flow, i.e., 1 litre per minute. If the flows were as low as a few hundred cc’s of gas, equivalent to the patients metabolic uptake of gases, this would be closed circuit anaesthesia, or metabolic (basal) flow, or minimal flow. Circle systems were first used back in 1930 by Brian Sword in the USA

Types of Semi Closed Circuit System Standard Parallel Y System Extendible Parallel Y System Complete Semi Closed Circuit Systems Co-Axial Semi Closed Circuit Systems

‘Tight Connections’ Remember, it is important with conical connectors such as those used on breathing systems, always connect with a firm push and twist. This will ensure a leak tight connection.

Conclusion The silver ion based anti-microbial additive reduced the potential risk of cross contamination from the outside of the breathing system

This means that the anti-microbial additive in Breathing Systems not only inhibits bacterial growth but will reduce colonisation on the circuit, and therefore can reduce cross infection in the ITU and the operating theatre

Well that’s it! ‘TIGHT CONNECTIONS’ I hope you now have a clearer understanding of Breathing Systems and Filtration. It really only leaves me one thing to say: ‘TIGHT CONNECTIONS’