Drew Hevle. NACE Houston Section Principal Corrosion Engineer

Slides:



Advertisements
Similar presentations
Underground Storage Tanks at Duke Duke Medical Center –8 permitted USTs located on medical campus –Range in size from 2,000 gallons to 30,000 gallons Proper.
Advertisements

Corrosion Products Sampler (CPS)
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
SAND CLEANING STATFJORD C FIELD TEST Stavanger 18 – 19 January 2006 Henrik Dannström, MATOR AS.
Ronald L. Baker Robert Peters Edul Chikhliwala EcoChem Analytics
Joe Killins & Associates, LLC Pipelines & Risk Based Management How Safe is Safe?
Science PowerPoint: William Freddy Curle. Definitions Electrode n. 1. A solid electric conductor through which an electric current enters or leaves an.
Carlsbad, New Mexico August 19, 2000 Pipeline Rupture and Fire El Paso Natural Gas Company: Gas Transmission Line No
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Calcite Contactors for Corrosion Control
TRANSPORTATION (Farm Gate to Processing Facility).
Hydrogen Fuel Cells. Basic electrochem Galvantic cell 2H 2 + O 2 → 2H 2 O Anode (oxidation) H 2 → 2H + + 2e- Cathode (reduction) O 2 + 4e- → 2O 2-
FLOW VELOCITY REQUIRED FOR SOLIDS MOVEMENT IN OIL AND GAS PIPELINES JOHN S SMART JOHN SMART CONSULTING ENGINEERS HOUSTON TX BLACK POWDER IN PIPELINES JOHN.
Gas Transmission Pipelines
ZF-100 The Paraffin & Asphaltene Solution. ZF-100 The Paraffin & Asphaltene Solution 72% Biodegradable, environmentally friendly ZF-100 is an aggressive.
Principles of Liquid Flow through Pipelines
Pigging.
Butch G. Bataller Lecture on ChE 192
Pipeline Corrosion Management NACE Houston Section April 9, 2013 Drew Hevle - Manager, Corrosion Control Kinder Morgan Natural Gas Pipeline.
Corrosion & Associated Degradation
Corrosion/Erosion PROCESS OUT OF CONTROL.
Oil Heat Properties of Fuel Oil.
Designing an Internal Corrosion Program NACE Eastern Area Conference Roy D. Fultineer Jr.
Water Supply & Management Obj: Discuss the nature, importance and sources of water.
Lease Automatic Custody Transfer
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Contaminant Control: a New Approach David Burns Scientific Process Solutions a division of Perry Equipment Corporation.
How to obtain fresh water Section - E6.3 Chemistry 12 – SL Isabelle R.
U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Harold Winnie, CATS Manager (Central Region) Leak detection for.
Lecture 1 Water Distribution Systems
Electrochemistry-Corrosion Corrosion. Involves oxidation of metal; often returning them to their natural state (oxides or ores) Happens because the oxidation.
Electrolytic Cell + - Electric Current AnodeCathode Iron Cathode Metallic Anode Asbestos/Teflon Permeable Diaphragm Each electrolytic cell includes an.
Western Regional Gas Conference August 24, 2010 Distribution Integrity Management Programs (DIMP) Rule.
Drain systems PAB Drain Systems Drain systems are important to allow equipment to be drained, opened, inspected and repaired If else, process fluids.
Part 3.3 Production Safety. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Understand safety.
Air Conditioning International Mechanical Code
NSF International Drinking Water Product Standards.
Basics of the Oil, Gas & Petrochemical Industries.
PROCESS PIGGING. 2 Process – Pigging In this course you will learn: The functions of pigging Terminology The different types of pigs In-line inspection.
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
Chapter 17 Corrosion and Degradation of Materials.
ABSORPTION.
E8 / PPA Solar PV Design Implementation O&M Marshall Islands March 31-April 11, Preventive Maintenance.
PIPELINE SPECIFICATIONS
TARNISH & CORROSION By Head of Department Dr. Rashid Hassan Assistant Professor Science of Dental Materials Department DENTAL SECTION (W.M.D.C) ABBOTTABAD.
1 Fe - CO2 Corrosion Rahmad Budi Arman Muhammad Pribadi.
Lynsay Bensman 06 October 2009 Errors in Sampling/Monitoring in an Internal Corrosion Program NACE Eastern Area Conference.
How Old is too Old? Who Makes that Decision? Alan Mayberry New Orleans, Louisiana Pipeline Safety Trust Annual Conference
Conducting Water Quality Tests. Next Generation Science / Common Core Standards Addressed! HS ‐ ESS2 ‐ 5. Plan and conduct an investigation of the properties.
How Do Batteries Work?  Eddy Giang  Scott Segawa  Eddy Giang  Scott Segawa.
Desalination for Drinking Water Purposes TCEQ Trade Fair David A. Williams, P.E Robert W. Sims, P.E. Austin, Texas May, 2016.
Harry D. Gong, Jr., P.E. Engineering Coordinator Drinking Water Revolving Loan Fund Bureau of Public Water Supply Mississippi State Department of Health.
Basic Corrosion Theory
Seating Nipple By-Pass System
Natural Gas Processing I Chapter 2 In-feed System
Natural Gas Production Chapter 4 Hydrate Formation
Water and Soil Corrosion
PRODUCTS (POWER PLANT)
Atmospheric Corrosion
Definition of Corrosion
Refinery: Separation units
IDENTIFYING CORROSION MECHANISMS BASED ON CORROSION COUPON ANALYSIS
Corrosion & Associated Degradation
Wet Gas Gathering Pipeline Failure – Internal Corrosion
TRENTON Casing Filler Presentation
Corrosion Part 3 Corrosion Protection Methods
Treatment –Reverse Osmosis (Desalination)
Steven L. Grise Brian J. Saldanha Oct 23, 2007
LOP Flare Pilot Outage Shell Martinez Refinery 7/6/18
Pneumatic System Conditioning
Presentation transcript:

Enhancing Pipeline Integrity with Early Detection of Internal Corrosion Drew Hevle NACE Houston Section Principal Corrosion Engineer June 9, 2009 El Paso Corporation

Disclaimer This presentation discusses components of an internal corrosion control program for natural gas and hazardous liquid pipeline systems It is not a discussion of the policies and practices of any particular pipeline operator

Internal Corrosion Four things are necessary in order for a corrosion cell to form: Anode Cathode Electrolyte Metallic path For internal corrosion to occur, an electrolyte (usually liquid water) must be present

Internal Corrosion Cell Electrolyte Cathode Anode Metallic path

Sources of Water Natural gas transmission pipelines typically transport tariff-quality gas, or “dry gas” Gas quality specifications designate a maximum moisture vapor content at a level where liquid water will not condense in the pipeline system under normal operating conditions Natural gas pipelines that transport hydrocarbon liquids and hazardous liquids pipelines typically allow BS&W including liquid water

Sources of Water Water accidentally introduced into the pipeline Upsets of liquid water at system inputs from production or storage High water vapor that allows liquid water to condense under operating conditions Failures to dehydration equipment can introduce water, water vapor, and glycol, which is hygroscopic Maintenance pigging and gas flow can move water to unexpected places

Sources of Water Water intentionally introduced into the pipeline Hydrotesting (long exposures, water quality, dewatering effectiveness) Water used to carry chemical treatments Self-inflicted (cleaning, management of pyrophoric materials, maintenance of dehydration equipment) Methanol injection to prevent freezing

Testing for water Product quality monitoring at system inputs Automated testing at inputs and in flow stream Liquid sampling (drips, pigging operations, vessels, sample pots) Testing for increases in water vapor content can identify areas of liquid holdup

Prevention Facilities design (filter/separators) Appropriate product quality standards Product quality enforcement actions Customer quality assurance valves Tracing the source and correcting problems Dehydration and liquid removal Effective de-watering following hydrotesting

Removing Water Re-absorption into gas stream Maintenance pigging Flow velocity Line sweeping (increased velocities [but not too high]) Liquid removal devices such as pipeline drips, filters, separators, slug catchers If these devices aren’t properly maintained, then you are simply moving the corrosion from the pipeline to the liquid removal device

Removing Water Conditions that may prevent water removal Repeated upsets Biomass Glycol can absorb water from low levels of water vapor Low/no flow Poor design, such as crevices, dead legs and diameter changes Sediment accumulation

If You Find Water Determine if it is an upset or persistent condition Determine the extent of pipeline affected Remove the water, if practical Gas and hydrocarbon liquids are not corrosive. Water may not be corrosive; pure condensed water has a very low conductivity Corrosive constituents in gas and liquids can accelerate corrosion rates

If You Find Water Perform testing on water to determine corrosivity Monitor with coupons/probes/other technology to determine if it is corrosive If the condition is persistent and the water is corrosive, implement a mitigation program Use chemical analysis to trace possible offenders (e.g. glycol)

Liquid and Solid Sampling Onsite testing Test for water pH Temperature Alkalinity Dissolved H2S Bacteria culture

Liquid and Solid Sampling Laboratory testing Test for water Compositional analysis Alkalinity pH Conductivity Salts Corrosion products Other tests

Gas sampling Water vapor Oxygen Carbon dioxide Hydrogen sulfide Other tests

Internal Corrosion Mitigation Remove water/corrosive constituents Chemical treatment (batch or injection) Internally coat (not a great option without cathodic protection, in many cases) Cathodic protection (usually not practical except for vessels/tanks) Material selection (usually not practical)

Internal Corrosion Mitigation Mitigation systems have to be monitored. For example, for a chemical injection system: Check pumps periodically to ensure proper operation Compare specified chemical injection rates with actual chemical consumption Test the chemical periodically to ensure that you are receiving the proper chemical at the specified concentration Monitor downstream for residuals to ensure proper distribution of chemical Monitor with coupons to ensure that the chemical is effective

Measuring Corrosion Rates In dry gas transmission pipelines, it is difficult to identify areas likely to have measurable corrosion rates, since the presence of water is extremely rare If likely locations for internal corrosion can be identified, they can be monitored with coupons, probes, ultrasonic thickness measurements, ultrasonic thickness arrays, hydrogen permeation, electrochemical noise, etc. Advancements in ILI data technologies allow calculation of internal corrosion rates across more significant intervals

Trust everyone, but cut the cards. Integrity Assessment Trust everyone, but cut the cards. - W. C. Fields

Integrity Assessments Ultrasonic thickness measurements at key locations Inspection of internal surface of the pipe when the pipe is open Repairs Pig launchers/receivers Meter tubes Vessels Tanks

Integrity Assessments Inspection for internal corrosion where historical accumulations of liquid water may have occurred: PHMSA Advisory Bulletin ADB-00-02 Drips, deadlegs, and sags, fittings and/or "stabbed" connections, operating temperature and pressure, water content, carbon dioxide and hydrogen sulfide content, carbon dioxide partial pressure, presence of oxygen and/or bacteria, and sediment deposits, low spots, sharp bends, sudden diameter changes, and fittings that restrict flow or velocity.

Integrity Assessments Periodic integrity assessments ILI ICDA Pressure testing Most effective prediction models for pipelines are incorporated into the ICDA standards (DG-ICDA, LP-ICDA, WG-ICDA)

Integrated programs An internal corrosion control program is part of integrity management The internal corrosion control program should prevent internal corrosion from occurring, and give the operator an idea of where and how much internal corrosion may have occurred Feedback of the results of integrity inspections to the internal corrosion control program is essential to ensure that the program is effective

Summary An internal corrosion control program consists of many components, including monitoring, prevention, maintenance, mitigation, and integrity assessment. Each component is necessary to a varying degree depending on the product being carried, operating history, operating conditions, risk, and expected life. An internal corrosion control program must be tailored to specific pipeline conditions

Summary The best solution is to keep the water out of the pipe

Questions?

Enhancing Pipeline Integrity with Early Detection of Internal Corrosion Pipeline Integrity Management Conference March 30th – April 1st 2009, Houston, Texas