Education You Can Build On White-Rodgers Gas Furnace Valves.

Slides:



Advertisements
Similar presentations
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Advertisements

Pilots & Accessories.
340 Voyager rooftop range Dual Fuel DKD/H Voyager II Voyager III kW Heat Pump Cooling Only Gas Fired
Coach Air Conditioning
For Steam Boilers & Hot Air, Fresh Air, et al.. Thermostat Demand Analysis over time resets burner fire time for steam boiler. This will remove the leads.
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Energy Efficient Steam Systems
Boiler Operation Procedures
Chapter 7 Flow Control Valves and Other Hydraulic Valves
VR8345 Universal Electronic Ignition Gas Valve Training Module
Gas Explosions Ireland Chapter IAAI By Jamie Novak Saint Paul Fire and Safety services Novak Investigations.
Installing & Testing Regulators
Customer Service – International dept. STAR 24 3 E.
Mass Flow Controller. Function Delivers user specified flow rate of gas. Flow rate is mass flow rate (i.e. number of molecules per sec Mol/sec), not volume.
HEAT PUMPS.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Heating Control Devices
Millivolt Troubleshooting Guide Gas Products NOVA SIT Valves 1) Thermocouple Millivolt Check 2) Safety Magnet Testing 3) Thermopile Millivolt Check 4)
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
HVAC121 – Gas Heat Flame Rectification.
S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)
Furnace Troubleshooting
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
Gas Furnace Controls Part 4.
Superheaters.
S8910U1000 Universal Electronic Ignition Modules Training Module
'36 G' Gas Valve.
Engineer Presentation
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Pressure Drop Basics & Valve Sizing
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems
Gas Furnace Planned Maintenance
HVAC523 Basic Subsystems.
Designing and Installing Exterior Vapor Distribution Systems
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
Temperature Control Loop
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
Valves In Industry (Part 3)
HVACR116 – Trade Skills Pipe Sizing Sizing Gas Pipe for Low-Pressure Systems.
Why Maintenance Tasks are Important Produced by Joe Marchese.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
1 HVAC122 - Gas Gas Valves. 2 Solenoid Gas Valves The solenoid gas valve is the simplest of all valves. This valve has an electrical magnetic coil which.
Student Handout Packet – Page A7
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
Page A5 Schematic Analysis for Sequence of Operation (AUTOMATIC Spark Ignition System)
LCD Wiring Diagram Presentation B / B.
Water Distribution Systems Pressures Locating Reservoirs Location in Ground.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
James McIntyre VRF Training Manager V5 Key Components.
Unit 7 Gas Heat: Natural and LP
Properties and combustion of fuel oils
Liquid Dehydration System
Structural Fire Engineering, October 2015, Dubrovnik, Croatia
HIGH PERFORMANCE LEVEL CONTROL.
B. A. T. Basic Appliance Training
S8910U1000 Universal Electronic Ignition Modules Training Module
HYDRAULIC SCHEME PRESS G SERIES.
VR8345 Universal Electronic Ignition Gas Valve Training Module
Parts Counter Bulletin
Presentation transcript:

Education You Can Build On White-Rodgers Gas Furnace Valves

When To Replace A Gas Valve? The valve should be replaced if any of the following occur: –The outlet pressure remains above the set point or fluctuates NOTE: The manifold regulation should stabilize after about 20 seconds and stay within +/- 10% of the set pressure setting –The regulation setting cannot be adjusted –The valve will not open to allow main gas flow –The gas valve has been subjected to water flooding NOTE: When servicing a gas furnace it is important that the inlet and the outlet pressures be checked with an accurate pressure gauge –You cannot visually look at a main burner flame to determine if the pressures are within the manufacturers specifications –Always check the gas valve with a water and soap bubble solution after servicing to ensure there are no leaks

QuestionsOptions What is the Ignition Source? Direct Burner Ignition Direct Spark Ignition Hot Surface Ignition Proven Pilot / Intermittent Pilot Standing Pilot What is the Furnace Input / Valve Rating? Look at the rating plate on the furnace NOTE: All White-Rodgers Universal Gas Valves come with Nat. to L.P regulator spring conversion kit and reducing bushings for adapting to pipe size What are the opening characteristics? Opening Curve Fast/Standard Open or Slow Stages Single Stage or 2 Stage Selection Criteria

Application by Ignition Source Direct Burner Ignition Proven / Intermittent Pilot Standing / Continuous Pilot Hot Surface Ignition (HSI) Direct Spark Ignition (DSI) W-R Valve36H or 36J 36H36C Ignition Source Resistive element that heats up to light the gas with direct or indirect flame sensor Ground electrode, with spark electrode flame sensor Pilot burner to ground, with a spark electrode and flame sensor A traditional pilot burner with a thermocouple - no spark electrode or flame sensor Usage Majority of current furnaces Selected applications Mostly rooftop applications No longer used in OEM production

Rated Valve Capacity W-R Valve Pipe Size Range of Regulation KBTU/HR (Min to Max) N.G.L.P. 36J ½ x ½40 to to H ½ x ¾30 to to 648 ¾ x ¾50 to to C ½ x ¾30 to to 469 ¾ x ¾50 to to 648 Pressure Drop : Pressure differential is the agency rated amount of gas (BTUs) that can pass through the gas valve based on inlet and outlet pipe size. Range of Regulation : Is the minimum and maximum BTU/Hr capacity of the valve to maintain regulation pressure settings.

Fast OpenSlow Open2-Stg Fast Open2-Stg Slow Open 36J22 36H32 36C03 36J24 36H33 36J54 36H64 36J55 36H65 Fast Open Fast rise to full outlet pressure upon energizing the valve Slow Open Slow increase of gas to full outlet pressure for smoother ignition Two-Stage Open Low pressure 1 st fire stage and then full outlet pressure on a call for 2 nd Stage Heat Can be fast or slow open on both stages Application By Opening Characteristics Note: These are Typical Family Model Numbers. Verify Specific Type Numbers Before Replacing A Control.

Universal Valves You Should Not Be Without Model Number Ignition Source N.G. Capacity L.P. Capacity Pipe SizeOpening Curve Stages 36J Direct Burner Ignition (HSI / DSI) 140,000226,800½ x ½ Fast1 36J24-214*Slow1 36J54-214Fast2 36J55-214*Slow2 * 36J valve is offered in a -614 Version that gives you a 90° Bottom OutletPrimarily used in Carrier Furnaces 36H Direct Burner Ignition Or Proven Pilot 260,000421,000½ x ¾Fast1 36H ,000486,000¾ x ¾ Fast1 36H33-412Slow1 36H64-463Fast2 36H65-401Slow2 36C Standing Pilot 230,000372,600½ x ¾Fast1 36C ,000453,600¾ x ¾Fast1 98% of Furnaces manufactured in the last 10 years can be repaired using the J valves listed above!