Global Discovery Chemistry, 11 August 2017

Slides:



Advertisements
Similar presentations
Instrumental Analysis
Advertisements

Screening of a Sulfonamides Library by Supercritical Fluid Chromatography Coupled to Mass Spectrometry (SFC-MS). Preliminary properties-retention study.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
REAL TIME PCR ………A step forward in medicine
Calibration Methods Introduction
World Health Organization
The geometry of capillary columns is fairly simple, consisting of length, internal diameter, and stationary phase thickness. Nevertheless, there are endless.
Chromatography.
Purity Identificaion of Crack-Coccaine Through the use of HPLC Rony Anderson 1, Eduardo de Jesus Oliveira 1, Kyle Wojciechowski 2 1- Laboratorio de Tecnologia.
Using Chromatography to Select Effective Biomineral Growth Modifiers Tissa J. Thomas and Ryan E. Sours Department of Chemistry, Towson University, Towson,
Acid-Base Titrations.
Instrumental Analysis
Simultaneous quantification of bergenin, catechin, and gallic acid from Bergenia ciliata and Bergenia ligulata by using thin-layer chromatography 张 慧.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
Analytical considerations
Comparison of Competitors’ Evaporative Light Scattering Detectors
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Budi Hastuti, S.Pd., M.Si.. INTRODUCTION  Two step analysis: 1. Identify  Qualitative Analysis 2. Estimation  Quantitative Analysis Method  Classical.
Advances in HPLC Purification of Peptides Future Benefits of In-house Integration Imre Sallay*, Keiji Koyanagi* and Oscar R. Rebolledo** *DAISO CO., LTD.,
Mike Rusak and Laura Fairburn CURRENT OBSTACLES ON THE APPLICATION OF AMBIENT IONIZATION MS IN FORENSICS.
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
HPLC – High Performance Liquid Chromatography
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Chemistry 2412 L Dr. Sheppard
Titration  Lab technique commonly utilized to determine an UNKNOWN concentration of a chemical compound with a KNOWN concentration of another chemical.
Selling Restek LC Solutions for Analytical Scale Laboratories Rick Lake Product Line Manager Liquid Chromatography x 2379
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Physiochemical properties of drugs Using the Sirius T3 to make measurements.
Lecture 8 Peak Parameters and Quantitative chromatography
Chapter 1: The Nature of Analytical Chemistry
3M Drug Delivery Systems 3 Introduction A family of hydrofluoroalkane-compatible excipients based on oligomeric lactic acid (OLA) has been proposed for.
EQUIPMENT and METHOD VALIDATION
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Fundamentals of Analytical Chemistry Eighth Edition.
Rachel Klein and Tasha Magloire
Chemical Ideas 7.6 Chromatography.
Introduction Results Aim of the study Methods Conclusion References
Chromatography- TLC & HPLC
Internal Standard method (experiment lab-4)
David S. Bell,Hugh Cramer and Craig R. Aurand Supelco/Sigma-Aldrich
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Mass Spectrometry Vs. Immunoassay
Quantitative Gas Chromatography
Chem. 31 – 11/1 Lecture.
High Performance Liquid Chromatography (HPLC)
Remedial Kinetics and Mechanism
An Introduction to Chromatographic Separations
An Introduction to Chromatographic Separations
Gel Filtration Chromatography.
Titration curve Typical ph titration of a weak monoprotic acid vs strong base.
ANALYTICAL METHOD VALIDATION
Chromatography Daheeya Alenazi.
Principle of separation of different components:
Liquid Chromatography - Method Development and Validation
How to quantify substances in a mixture using gas chromatography
Microbiome: Metabolomics
Levofloxacin structural formula
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Transferring LC-UV to LC-MS.
High performance liquid chromatography (HPLC)
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
Presentation transcript:

Global Discovery Chemistry, 11 August 2017 Development of a Microscale Quantification Model Using Charged Aerosol Detection D. Spencer, D. Dunstan, C. Springer Global Discovery Chemistry, 11 August 2017 Context Log-Log Plots of Area vs. Conc. For CAD and ELSD There is a demand for a universal detection method in analytical chemistry to quantify small quantities of compounds, especially in the pharmaceutical industry. Quantification of microscale quantities usually requires expensive and complex equipment that can inhibit the fast output that is required in modern-day pharmaceutical labs. Ultra-high performance liquid chromatography (UPLC) coupled to charged aerosol detection (CAD) has been utilized as a cheaper and easier alternative. Despite these benefits, CAD is not a universal technique that applies to all compounds and is affected by acetonitrile composition of the inlet flow, chemical structure, and modifier. A computer model has been developed to work with UPLC-CAD results to allow for the rapid and high throughput and quantification of sub-milligram quantities, greatly improving the efficiency and turnover of drug discovery programs. Validation of Computer Model Figure 1: When plotted on a log-log scale, the signal peak area shows a linear dependence on the concentration of the analyte.[1] CAD proved more accurate and consistent in slope than ELSD. Calibration curves were generated for 30 small-molecule drugs over a range of MW, structures, and volatilities. Top: CAD, Bottom: ELSD Effect of % ACN on CAD Area Effect of Mobile Phase Acidic Modifier on CAD Signal Figure 2: Test of small-molecule drugs of concentrations determined by NMR using a computer model developed with approximately 30 compounds to create a universal calibration curve. Numerical results appear in Table 1 Log([Analyte]) = 1.08*Log(CAD Area) + B The computer model takes into account factors such as chemical structure, the number of heavy atoms, and the amount of ACN present in the mobile phase at the time of elution. The model calculates B for each compound but the slope was consistent across compounds at 1.08. Figure 4: Effect of acidic modifier in the mobile phase on the CAD signal peak area was tested using two different acidic modifiers: formic acid (pKa = 3.77) and TFA (pKa = 0.23). The TFA yielded a sharper peak shape than formic acid giving an increased signal for amitriptyline and trimipramine, both with strong basic centers. Percent differences between peak areas using the two modifiers were found for the 16 small-molecule drugs and calculated by [(AFormic – ATFA) / ATFA] * 100% Figure 3: The percentage of the mobile phase that is composed of organic solvent affects the CAD signal peak area exponentially for semi-volatile, lower MW compounds and according to the above trend for non-volatile compounds. Three different injection volumes were used to demonstrate linearity and expand dynamic range of detector Conclusions Compound CAD Peak Area NMR Conc. (mM) Intercept from Model Model Conc. (mM) Error (%) Sulfamethizole 8.29 13.38 -0.12 7.28 45.58 Sulfamethoxazole 10.04 12.99 -0.23 7.15 44.97 Quinizarin 12.44 9.35 -0.09 12.09 29.31 Flavone 7.52 11.67 -0.07 35.58 Sulfamethazine 6.83 9.34 -0.14 5.72 38.81 Ibuprofen* 0.72 8.06 0.53 93.46 Fenofibrate** 22.88 8.34 -0.41 11.35 36.09 Oxprenolol HCl 9.884 6.77 -0.17 8.02 18.40 Naproxen 12.14 10.17 10.67 4.90 Determined that CAD is more consistent and universal than ELSD or UV detection Investigated effect of composition of mobile phase and chemical structure on CAD signal Quantification model will be used in automated microscale purification workflow to enable rapid synthesis to DMSO stock of novel compounds Future directions: more testing and validation of model to improve accuracy by retraining, optimizing conditions and accounting for effects of modifier, ACN content, volatility[1] etc. Potential applications: rapid high-throughput screening of compounds, quantifying concentrations of metabolites in vivo, universal detection Where do YOU see an application for this? (1) J.P. Hutchinson, J. Li, W. Farrell, E. Groeber, R. Szucs, G. Dicinoski, P.R Haddad, Journal of Chromatography A. 2010, 1217, 7424. Table 1: Summary of validation data for computer model using a variety of small molecule compounds of varying volatility and MW. Concentration determined by model compared against that determined by NMR. Average error = 31.71%. Model uses equation: 1.08*Log(CAD Area) + B, where B is the intercept determined by the model *Low model concentration due to compound volatility ** Model corrects for high CAD peak area