Portable Fire extinguisher

Slides:



Advertisements
Similar presentations
SCS East Region Safety & Health
Advertisements

Fire Extinguishers 29 CFR Session Objectives You will be able to: Identify different classes of fire Choose the appropriate type of extinguisher.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Portable Extinguishers Firefighter I
Portable Fire Extinguishers
FIRE EXTINGUISHER TRAINING
Fire Safety & Fire Extinguisher Use
Portable Fire Extinguisher Safety Emergency Procedures.
The Use of Portable Fire Extinguishers
EXTINGUISHER BASICS D INTRODUCE YOURSELF. REMIND STUDENTS ABOUT:
PORTABLE FIRE EXTINGUISHER TRAINING Section Montana Department of Labor & Industry Occupational Safety and Health Training Institute.
Fire Extinguishers Regis College Department of Public Safety.
Fire Prevention & Protection Gordon Cooper Technology Center
Cordelia Fire District Prepared by: Bryan Thompson.
Portable Extinguishers
Fire Prevention.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
PORTABLE& OTHER FIRE EXTINGUISHING SYSTEM Fire extinguisher= Is a device within its chemical, fluids,& gases for extinguishing and used for small area.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
7 Portable Fire Extinguishers Captain Walker. 2 Objectives (1 of 2) State the primary purposes of fire extinguishers. Define Class A fires. Define Class.
CLASSES OF FIRE Class “A” – combustible materials
Fire Extinguisher Training Instructions For Use: To load the fire extinguisher training program, click on the projection screen icon in the lower right.
Fire Extinguishers Essentials Chapter 6 Gwinnett County Fire Academy.
Fire extinguisher Training. COURSE TITLE:FIRE EXTINGUISHER SAFETY AWARENESS Venue: Fire /Safety classroom – Fire training ground. Duration : 4 Hours Classroom.
Fire Extinguisher Safety EDM Services, Inc. June 2008.
CHAPTER 8 PORTABLE FIRE EXTINGUISHERS Copyright© Delmar is a division of Thomson Learning.
Fire Safety & Fire Extinguisher Use. OBJECTIVES Understand the combustion process and different fire classes Understand fire extinguisher types, operating.
PORTABLE FIRE EXTINGUISHERS
What is fire? Definition: A self-sustaining rapid oxidation of a combustible material giving off heat and light.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
Fire Detection and Suppression Chapter 1 Fire Extinguishing Agents and Portable Fire Extinguishers.
CHAPTER 8 Copyright © 2007 Thomson Delmar Learning 8.1 Portable Fire Extinguishers.
Fire Extinguisher Training
A fire needs oxygen, fuel, and a source of ignition. With out all three you do not have a fire.
Fire Hazards (this is not an introduction to urban warfare)
Chapter 6 Portable Fire Extinguishers. Fire Extinguishment Methods Smothering Cooling Chain breaking Saponification.
California Lutheran university Fire Extinguisher Training.
Fire Extinguisher Training
FIRE EXTINGUISHER D TRAINING. Objectives Understand the combustion process and different fire classes. Understand the combustion process and different.
Using a Fire Extinguisher Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1PPT
Fire Extinguisher Primer 10-4 training 10 Slides, 4 minutes.
Fire Extinguishers 29 CFR © Business & Legal Reports, Inc Session Objectives You will be able to: Identify different classes of fire Choose.
Fire Extinguishers Industrial / Home. Objectives Identify the classification of types of fire as they relate to the use of portable extinguishers Identify.
Fire Extinguishers Burlington Fire Department 215 S Church Street, Burlington, NC
Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 7 — Portable Fire Extinguishers.
Portable Fire Extinguishers MFRI Drill of the Month August 2016 Instructor Danny Braitsch.
Fire Extinguisher Training
Safety in the lab and the work place
Fire Extinguisher Guidance (Theory)
“Portable Fire Extinguishers Safety”
Fire Extinguisher Training
Fire Extinguisher Training
Portable Fire Extinguisher Training
BASIC FIRE PREVENTION AND CONTROL SEMINAR
SCS East Region Safety & Health
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
Fire Safety & Fire Extinguisher Use
Approval Sheets.
Fire Extinguisher Training
SCS East Region Safety & Health
نظرية الإطفاء أجزاء الطفاية أنواع الطفايات استخدام الطفاية
Presented by: City of Radcliff Safety Council
Fire Safety & Fire Extinguisher Use
Fire Safety & Fire Extinguisher Use
Fire Safety & Fire Extinguisher Use
Fire extinguisher training
SCS East Region Safety & Health
Portable Extinguishers
Fire Extinguishers 101.
Fire Extinguisher Training Presented by:. The Fire Triangle The Fire Triangle is a simple model used to understand the ingredients necessary for most.
Presentation transcript:

Portable Fire extinguisher

MOTIVATION Portable fire extinguishers can provide the firefighter with another tool for fire fighting. Of all the equipment used by firefighters, the portable fire extinguisher is probably the least understood. It is important that firefighters have a working knowledge of portable fire extinguishers, especially since they are perhaps the most readily available firefighting tools at the firefighter’s disposal. We live in a world regulated by codes and standards, therefore, in almost any commercial or industrial building, and a large percentage of residential structures, there are portable extinguishers. The firefighter must understand how fire extinguishers work, not only to perform better at fires, but to better educate the public as to how portable fire extinguishers play a part in fire prevention. The extinguisher is an excellent tool for combating small, incipient stage fires. With the speed that a firefighter can use an extinguisher, it is much easier and faster than using an attack line. However, only extensive training will prepare the firefighter in the appropriate use of fire extinguishers.

FIRE EXTINGUISHERS

The Fire Triangle Fuel Oxygen Heat Fuel Oxygen Heat Fuel Fuel Oxygen

REVIEW OF CLASSES OF FIRE Class A -Ordinary Combustibles: Wood, Cloth, Paper, Rubber, Plastic Class B -Flammable Liquids: Gasoline, Oil, Lacquer, Paint, Mineral Spirits, and Alcohol Class C -Energized Electrical Equipment: Household Appliances, Computers, Transformers, and Overhead Transmission Lines Class D -Combustible Metals: Aluminum, Magnesium, Titanium, Zirconium, Sodium, and Potassium Class K –Combustible Cooking Media: Vegetable or Animal Oils and Fats

AGENTS USED IN FIRE EXTINGUISHERS Pump tank & backpack pump (water). Stored pressure (water). AFFF (aqueous film forming foam). Halon 1211 (bromochlorodifluromethane). Halon 1301 (bromotrifluoromethane). Co2 (liquefied compressed gas). Dry Chemical (ordinary and multipurpose).

STORED PRESSURE VS PUMP TANK WATER Stored pressure can be used on small Class A fires, small hot spots especially during overhaul operations, and chimney fires. The difference between the two is that the air pressurized uses air pressure or nitrogen gas to expel the water, whereas, the pump tank water is manually pumped to siphon water.

HALON EXTINGUISHERS Usually used to protect energized electrical equipment (Class C fires) found in computer server rooms, etc. The Montreal Protocol on Substances that Deplete the Ozone Layer requires a complete phaseout of the production of halogens by the year 2000. The U.S. stopped producing halogens at the end of 1993. However, these units may still be found.

WARNING When halon is used to extinguish a fire, it decomposes and liberates toxic components, so these agents should not be used in unventilated, confined spaces.

CARBON DIOXIDE EXTINGUISHERS CO2 extinguishers are effective in extinguishing Class B and C fires. Carbon dioxide gas displaces available oxygen and smothers the fire. Re-ignition is a danger.

CARBON DIOXIDE EXTINGUISHERS CAUTION: Never mix or contaminate dry chemicals with any other type of agent because they may chemically react and cause a dangerous rise in pressure inside the extinguisher.

DRY CHEMICAL EXTINGUISHERS Dry chemical agents are for use on Class A-B-C fire and/or Class B-C fires. The following are commonly used dry chemicals: Sodium bicarbonate Potassium bicarbonate Urea-potassium bicarbonate Potassium chloride Monoammonium phosphate

TYPES OF HANDHELD DRY CHEMICAL EXTINGUISHERS Stored-pressure –similar in design to the air-pressurized water extinguisher, and a constant pressure of about 200 psi. Cartridge-operated –employs a pressure cartridge connected to the agent tank which becomes pressurized by a plunger once activated. The cartridges are carbon dioxide.

CO2 VS DRY CHEMICAL EXTINGUISHERS One advantage to using a CO2 extinguisher has over a Dry Chemical fire extinguisher is that it does not leave a residue or corrode electrical contacts.

WHEELED DRY CHEMICAL EXTINGUISHERS Dry chemical wheeled units are similar to the handheld units but on a larger scale. They are rated for Class A, Class B, and Class C fires based on the dry chemical in the unit.

WHEELED DRY CHEMICAL EXTINGUISHERS CAUTION: The top of the extinguisher should be pointed away from the firefighter or other personnel when pressurizing the unit. Because of the size of the nozzle, the firefighter should be prepared for a significant nozzle reaction when it is opened.

DRY POWDER EXTINGUISHERS No single agent will control or extinguish metal fires! Portable extinguishers for Class D fires come in both handheld and wheeled models. The agent must be applied in sufficient depth to completely cover the area that is burning to create a smothering blanket. Then, a 1- to 2-inch layer of powder should be spread nearby and the burning metal shoveled onto this layer with more powder added as needed. After extinguishment, the material should be left undisturbed.

CLASS K EXTINGUISHERS Extinguishing agent is a potassium acetate with a low PH and actually lowers the temperature of the burning material even after the fire has been extinguished. It was designed to discharge a fine mist to help prevent grease splash and fire reflash for the non- expert user at a safe distance from the fire. It can be used on Class C and even some Class A fires and leaves no “dry chemical residue” for clean- up. Required in the cooking areas of all Commercial buildings.

CLASS K EXTINGUISHERS Class K fire extinguishers shall be provided for hazards where there is a potential for fires involving combustible cooking media (vegetable or animal oils and fats). Maximum travel distance shall not exceed 30 ft from the hazard to the extinguishers.

CLASS K

PORTABLE FIRE EXTINGUISHERS RATINGS Class A extinguisher - rated 1-A through 40-A. Class B extinguisher -- rated 1-B through 640-B. Class C extinguisher -- agent tested for electrical non- conductivity. Class D extinguisher -- rated on types of combustible metal.

PORTABLE FIRE EXTINGUISHERS RATINGS For a 1-A rating, 1 ¼ gallons of water are required. A 2-A requires 2 ½ gallons or twice the 1-A capacity. The rating for Class B is based on the approximate square foot area of a flammable liquid fire that a nonexpert operator can extinguish.

SELECTION FACTORS Classification of the burning fuel. Rating of the extinguisher. Hazards to be protected. Severity of the fire. Atmospheric conditions. Personnel available. Ease of handling. Life hazard or operational concerns.

FIRE EXTINGUISHER SIZE AND PLACEMENT FOR CLASS A HAZARDS Criteria *Up to two water-type extinguishers, each with 1-A rating, can be used to fulfill the requirements of one 2-A rated extinguisher †Two 2 ½ gallon water-type extinguishers can be used to fulfill the requirements of one 4-A rated extinguisher ‡See E.3.3 Light (Low) Hazard Occupancy Ordinary (Moderate) Hazard Occupancy Extra (High) Minimum rated single extinguisher 2-A* 4-A† Maximum floor area per unit of A 3000 ft2 1500 ft2 1000 ft2 Maximum floor area for extinguisher 11,250 ft‡ Maximum travel distance to extinguisher 75 ft

FIRE EXTINGUISHER SIZE AND PLACEMENT FOR CLASS B HAZARDS Type of Hazard Basic Minimum Extinguisher Rating Maximum Travel Distance to Extinguishers Light (Low) 5-B 10-B 30 ft 50 ft Ordinary (Moderate) 20-B Extra (High) 40-B 80-B

INSPECTION PROCEDURES FOR FIREFIGHTERS External condition –no apparent damage Hose/nozzle –in place Weight –feels as though it contains agent Pressure gauge (if available) –in operable range

INSPECTION PROCEDURES FOR THE PUBLIC Extinguisher in proper location & accessible. Inspect discharge horn & nozzle. Operating instructions legible. Check lock pins & tamper seals. Full of agent and/or fully pressurized. Date of previous inspection (determined by code). Condition of hose & fittings.

RECORDS Month. Year. Type of maintenance. Date of last recharge. Building owners should keep the following records on maintenance and inspections: Month. Year. Type of maintenance. Date of last recharge.

PORTABLE FIRE EXTINGUISHER VALUES Three important factors that determine the value of a fire extinguisher: Serviceability. Accessibility. Users ability to operate.

MAINTENANCE CHECK Maintenance procedures should include examination of three basic parts: Mechanical parts. Extinguishing agents. Expelling means.

REPAIRS Leaking hoses, gaskets, nozzles, and loose labels can be replaced by firefighters. Leaking, corroded, or otherwise damaged extinguisher shells or cylinders should be discarded or returned to the manufacturer for repair. If an extinguisher shows only slight damage or corrosion but it is uncertain whether or not the unit is safe to use, it should be hydrostatically tested by either the manufacturer or a qualified testing agency.

CAUTION Never attempt to repair the shell or cylinder of a defective fire extinguisher. Contact the manufacturer for instructions on where to have it repaired or replaced.

HYDROSTATIC TEST INTERVAL FOR EXTINGUISHERS Extinguisher Type Test Interval (Years) Stored-pressure water, loaded stream, and/or antifreeze 5 Wetting agent AFFF (aqueous film forming foam) FFFP (film-forming fluoroprotein foam) Dry chemical with stainless steel shells Carbon dioxide Wet chemical Dry chemical, stored-pressure, with mild steel shells, brazed brass shells, or aluminum shells 12 Dry chemical, cartridge- or cylinder-operated, with mild steel shells Halogenated agents Dry powder, stored-pressure, cartridge- or cylinder-operated, with mild steel shells

OBSOLETE EXTINGUISHERS Soda-acid extinguisher. Inverted foam extinguisher. Cartridge-operated water extinguishers. Liquid carbon tetrachloride extinguishers. Copper or brass with cylinders either soft soldered or riveted Should have been removed from service by January, 1982

OPERATING PORTABLE FIRE EXTINGUISHERS P-A-S-S P -Pull the pin A -Aim the nozzle at the base of the fire S -Squeeze the handle S -Sweep at the base of the fire

QUESTIONS?

REMEMBER…

LET’S GO PUT THE WET STUFF ON THE RED STUFF THEN!