Scour Analysis on the west fork of the Duchesne River

Slides:



Advertisements
Similar presentations
CHAPTER FOUR Stream flow measurement
Advertisements

Example: Uniform Flow at Known Q and y
Streamflow and Runoff The character, amount, and timing of discharge from a basin tells a lot about flow paths within the basin Therefore, important to.
End of Chapter 4 Movement of a Flood Wave and begin Chapter 7 Open Channel Flow, Manning’s Eqn. Overland Flow.
CHARACTERISTICS OF RUNOFF
Design of Open Channels and Culverts CE453 Lecture 26
U.S. Department of the Interior U.S. Geological Survey February 29, 2012 – Washington, D.C. A GIS Flood Tool for Mapping Extent of Inundation James Verdin.
Design of Open Channels and Culverts
Hydraulics Engineering
Start Audio Lecture! FOR462: Watershed Science & Management 1 Streamflow Estimation Module 8.6.
How do we measure how much water is in a stream?
FLOODS, STREAMS AND MEANDERS. GAUGING STATION On all major streams Measures Stream Height Height vs. Discharge (volume) Flood Stage and height above Flood.
HEC-RAS US Army Corps of Engineers Hydrologic Engineering Center
EAS 345 Lab #4 SolutionsHEAT AND HYDROLOGY: EVAPORATION AND SNOWMELT 1. Calculate the depth of water,  z that will evaporate in 8 hours if the average.
1 River Processes and Morphology A Case Study of the Souteyran valley.
Part 2 Some Basic Aspects of CHANNEL HYDRAULICS. The volume of water that passes by any given point along a watercourse is called “Q”, for quantity of.
Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013.
We will now move on to study rating curves for natural channels
CH 7 - Open Channel Flow Brays Bayou Concrete Channel Uniform & Steady
Hydraulic Engineering
Time of Travel. American Water Charleston intake on the Elk River Charleston 1,000, ,984 = 1880 seconds or 31 minutes.
MA BF REFERENCE CURVES Objective Develop bankfull regional curves and equations for estimating bankfull width, mean depth, cross-sectional area, and discharge.
CHANNEL EFFICIENCY Channel Roughness. It is often thought that the velocity of a river is greatest near its start. This is not the case, as large angular.
Lesson 9 Channel characteristics
SPILLWAY RATINGS and STABILITY DESIGN PROCEDURES __________________________ SITES 2005 INTEGRATED DEVELOPMENT ENVIRONMENT for WATER RESOURCE SITE ANALYSIS.
Lecture 13 Design of erodible and non-erodible, alluvial channels- Kennedy’s and Lacey’s theories.
Basic Hydraulics: Channels Analysis and design – I
Bradshaw Model. Upstream Downstream Discharge Occupied channel width Channel depth Average velocity Load quantity Load particle size Channel bed roughness.
Open Channel Hydraulics
Basic Hydraulics: Open Channel Flow – I
David Tarboton Digital Elevation Models, Flood Inundation Mapping and River Hydraulic Properties David Tarboton
Aims today: To learn about: Channel Efficiency The Hydraulic Radius
1D Hydraulic Modeling w/ LiDAR Data Noah J. Finnegan 1 1 UC Santa Cruz, Earth & Planetary Sciences.
Hydrology and Water Resources RG744 Institute of Space Technology November 13, 2015.
RIVER CHANNEL CALCULATIONS
Sanitary Engineering Lecture 7
What is the Bradshaw model?
Open Channel Hydraulic
Anthony Alvarado, PE, CFM National Hydraulic Engineering Conference
Manning’s Equation Gauckler(1867)–Manning–Strickler (1923)
Norman W. Garrick Design of Grass Swales.
UNIFORM FLOW AND DESIGN OF CHANNELS
Expression Session Summarise “stream discharge” and “river load” using diagrams to assist your answer.
ERT 349 SOIL AND WATER ENGINEERING
4 channel types defined at reach scale, based on 3 features
Fluvial Geomorphology
Uniform Open Channel Flow
4 channel types defined at reach scale, based on 3 features
The Tank Hollow Fire and the Increase of Flood Potential for Spanish Fork Jaxon White.
Elizabeth Stanley Mann Meghan Kirsch
What Causes Flooding along the Logan river
Open Channel Storm water Irrigation Waste water collection and treatment.
Summary In addition to the oceans, where else is water found on Earth?
UH-Downtown White Oak Buffalo.
Discharge, stream flow & channel shape
CHAPTER FOUR Stream flow measurement
CLASS PLAN RIVER BEHAVIOR FLOW GAUGING MANNING’S EQUATION
Comparing NFIE RAPID models with measured river flood hydrographs.
CHAPTER FOUR Stream flow measurement
Flooding Potential in Bloomington, Idaho
CHAPTER FOUR Stream flow measurement
Hydrotechnical Design Guidelines for Stream Crossings
Use of ArcGIS to extract river geometry as an input to HECRAS model and prepare inundation, and velocity maps Term Project, CEE 6440, Fall 2016 Presented.
Fluvial Hydraulics CH-3
Fluvial Hydraulics CH-3
Unit 4: Weathering, Erosion and Landscapes
Automated Techniques for Hydraulic Modeling Applications
Example 3.E - Graf Assume a channel with uniform flow at a depth of 5.03 m. Channel is rectangular with a width of 9 m and average velocity of 12 m/s.
Flood Inundation Mapping using Height Above Nearest Drainage Method
Flood Inundation Mapping
Presentation transcript:

Scour Analysis on the west fork of the Duchesne River By: Tanner Sweat November 20, 2018 CEE 6440

Overview Background Design Project Height Above Nearest Drainage (HAND) Rating Curve

background

Background Bank Erosion below the Dugway Bank Erosion Dugway West Fork of Duchesne River Bank Erosion Bank Erosion below the Dugway

Design project Riprap Design Variables Velocity Depth Flow Design Riprap to Armor Stream Bank Riprap Design Variables Velocity Depth Flow HAND Analysis http://www.boulder-walls.com/?page_id=69

Design Flow Needed a Design Flow Stream Stats 5 years of flow data Q = 165.6 cfs 25 Year Flood Q = 518 cfs http://www.boulder-walls.com/?page_id=69

Hand Analysis Used NHD Streams and DEM to perform Hand Analysis

Rating curve Peak Recorded 25 Year Peak Flood Design Flow Q = 165.65 Stage Height (m) y = 1 6 10 14 Stage Height (ft) 3.2808 19.6850 32.81 45.93 Cell Size (m2) Acell = 100 Flooding Cell Num Ncell = 455 1,327 1,977 2,638 Average Bed Slope Sb = 1.000985 1.0144 1.02234 1.02697 Area of Water Surface (m2) As = 45,500 132,700 197,700 263,800 Average Bed Area (m2) Ab = 45,544.8 134,608 202,117 270,915 Avg Inundation Depth (m) d = 0.674 3.683 5.7991 7.8342 Water Volume (m3) Vol = 30,648 488,794 1,146,485 2,066,652 Reach Length (m) L = 2,227 Reach Start Elev (m) z1 = 2,547.8 Reach End Elev (m) z2 = 2,512.4 Cross Sectional Area (m^2) A = 13.8 219.5 514.8 928.0 Wetted Perimeter (m) P = 20.5 60.4 90.8 121.7 Hydraulic Radius (m) R = 0.67 3.63 5.67 7.63 Channel Slope (m/m) S = 0.0159 Mannings "n" n = 0.05 Flow (m3/s) Q = 26.6 1,307.5 4,128.9 9,067.9 Flow (cfs) 941.07 46,174.63 145,809.7 320,231.3   Peak Recorded 25 Year Peak Flood Design Flow Q = 165.65 cfs 518 Stage Height y = 2.99 ft 3.13 0.911 m 0.954

Rating curve Stage Height (m) y = 0.5 1 2 3 6 10 14 Stage Height (ft) 1.6404 3.2808 6.56 9.84 19.68504 32.8084 45.9318 Cell Size (m2) Acell = 100 Flooding Cell Num Ncell = 303 455 667 843 1327 1977 2,638 Average Bed Slope Sb = 1.000380 1.0010 1.00325 1.00620 1.0143748 1.0223397 1.026971 Area of Water Surface (m2) As = 30,300 45,500 66,700 84,300 132700 197700 263,800 Average Bed Area (m2) Ab = 30,311.5 45,545 66,917 84,823 134607.53 202116.56 270,915.0 Avg Inundation Depth (m) d = 0.385 0.674 1.3112 1.9265 3.6834502 5.7991164 7.834 Water Volume (m3) Vol = 11,672 30,648 87,460 162,402 488793.85 1146485.3 2,066,652 Reach Length (m) L = 2,227 2227 Reach Start Elev (m) z1 = 2,547.8 2547.8 Reach End Elev (m) z2 = 2,512.4 2512.4 Cross Sectional Area (m^2) A = 5.2 13.8 39.3 72.9 219.48534 514.81154 928.0 Wetted Perimeter (m) P = 13.6 20.5 30.0 38.1 60.443436 90.757322 121.7 Hydraulic Radius (m) R = 0.39 0.67 1.31 1.91 3.6312518 5.6723968 7.63 Channel Slope (m/m) S = 0.0159 0.0158958 Mannings "n" n = 0.05 Flow (m3/s) Q = 7.0 26.6 118.4 283.5 1307.5188 4128.8667 9,067.9 Flow (cfs) 247.02 941.07 4,180.5 10,012.7 46174.634 145809.69 320,231.27

Summary USED DEM and NHD Streams Data to perform HAND Analysis Determined Design Flows Highest Recorded Q = 165.65 cfs 25 Year Flood Q = 518 cfs Developed Rating Curve for Stream Reach Use Hydraulic Properties of Stream Reach to Design Riprap

Questions?