Likert-scale agreement ratings regarding the use of extubation readiness parameters by pediatric critical care physicians. Likert-scale agreement ratings.

Slides:



Advertisements
Similar presentations
Effect of nasal positive expiratory pressure (PEP) on 6-min walk test (6MWT) distance and pre- to post-exercise increase in lung volumes in each individual.
Advertisements

The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Airway pressure and flow waveforms during constant flow volume control ventilation, illustrating the effect of an end-inspiratory breath-hold. Airway pressure.
Trigger pressure-time product (PTP) with zero pressure support, with no leak, medium leak, and large leak. Trigger pressure-time product (PTP) with zero.
Spearman rank correlation between absolute humidity and the patient's core temperature with the Humid-Heat device. Spearman rank correlation between absolute.
Lung CT images were obtained while tracing the curve in static conditions. Lung CT images were obtained while tracing the curve in static conditions. Note.
Matrix used to calculate the kappa statistic.
Lung simulator diagram of airway pressure release ventilation (APRV): volume (yellow), lung pressure (white), and flow (orange)/time curve. Lung simulator.
Trigger delays and leaks.
Picture of bubble PEP devices.
Flow chart of pressure support test and spontaneous breathing trial (SBT). Flow chart of pressure support test and spontaneous breathing trial (SBT). The.
A: Pressure (green) and volume (black)/time curve in airway pressure release ventilation (APRV). A: Pressure (green) and volume (black)/time curve in airway.
An example of delayed cycling during pressure-support ventilation of a patient with COPD, on a Puritan Bennett 7200 ventilator, which has a flow-termination.
Example airway pressure and rib-cage impedance in a premature infant supported with the biphasic mode of SiPAP (“sigh” positive airway pressure) from the.
Simulated screenshot of flow starvation in volume control continuous mandatory ventilation. Simulated screenshot of flow starvation in volume control continuous.
Characteristics of a pressure-supported breath.
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value, Area Under the Curve, and 95% CIs for the 0, 10, 25, 50, and 100 SatSeconds.
Comparison of airway pressure release ventilation (APRV) (blue curve) and biphasic positive airway pressure (BIPAP) (black curve). Comparison of airway.
Trigger and synchronization windows.
Typical pressure-time curves during forced expiration against an occluded airway in cystic fibrosis (CF) patients and healthy controls. Typical pressure-time.
This tracing depicts 30 seconds of information.
Graphic representation of a dynamic airway pressure scalar during volume control ventilation with a constant inspiratory flow. Graphic representation of.
Effect of respiratory mechanics on cycling of pressure support from inhalation to exhalation. Effect of respiratory mechanics on cycling of pressure support.
Flow, esophageal pressure, airway pressure, and transpulmonary pressure can be used to calculate respiratory system compliance, chest-wall compliance,
Negative pressures calculated with the Rosen and Hillard formula
We connected the supplemental oxygen supply at 3 places: near the ventilator, near the exhalation valve, and on the nasal mask port. We connected the supplemental.
The curved Macintosh blade and straight Miller blade in standard adult sizes (Macintosh size 3, Miller size 2), with different handle choices available.
Blom speech cannula. Blom speech cannula. Inspiratory pressure opens the flap valve and closes (expands) the bubble valve, sealing the fenestration so.
Change in mean pulmonary arterial pressure after a 5-min inhalation of the Rho kinase inhibitor Y in rats with hypoxic pulmonary hypertension, with.
Process control chart of the mean monthly time between emergency department assessment/bronchodilator treatment and emergency department discharge. Process.
The Boussignac continuous positive airway pressure (CPAP) is a small plastic cylinder that attaches to a face mask. The Boussignac continuous positive.
Control circuit for set-point or dual targeting schemes.
A: Optimal cutoff point (circled) at which visual analog scale score categorizes subjects with versus those without bronchial obstruction. A: Optimal cutoff.
Study protocol. Study protocol. Subjects with hemodynamic, respiratory, and neurologic stability and positive predictive index were randomized to 3 groups.
Breathing frequency and PaCO2: comparison between high-flow nasal cannula oxygen therapy (HFNC) and comparative therapies in 8 studies. Breathing frequency.
Control circuit for a servo targeting scheme (eg, Proportional Assist Ventilation). Control circuit for a servo targeting scheme (eg, Proportional Assist.
Inspiratory time in excess (TIex) with the 10 ventilators tested under 3 conditions: in the absence of leaks and with the NIV algorithm deactivated (L0NIV0),
Negative pressures generated in our airway model.
A: Pressure ulcer on the left cheek of a patient after 1 week of prone positioning using a commercially available endotracheal tube (ETT) holder. A: Pressure.
Mortality rate according to our integrated index that combines DH and exercise capacity. Mortality rate according to our integrated index that combines.
The cause of asynchrony during volume-targeted ventilation and total asynchrony index. The cause of asynchrony during volume-targeted ventilation and total.
SpO2 at baseline, pre- and post-intubation.
Calculated negative pressure developed in the lung plotted against the outside diameter of the suction catheter to the inside diameter of the airway. Calculated.
Bland-Altman analysis of the end-tidal carbon dioxide concentration (PETCO2) during resting (A), with mouth closed (B), and during deep breathing (C) while.
Components of a patient-triggered mechanical breath.
FEV1 and FVC for the control group (without noninvasive ventilation [NIV]), NIV with an inspiratory pressure (IPAP) of 15 cm H2O and expiratory pressure.
Indications for ventilation in children and adolescents
Impact of craniofacial anomaly on face mask-related skin compromise.
Correlation between maximum inspiratory pressure and inspiratory load compensation (ILC) ventilatory variables in the 16 difficult-to-wean subjects, prior.
Airway pressure and flow graphics illustrate delayed cycling.
PaO2/FIO2, leukocyte count, and C-reactive protein during the first 10 days after out-of-hospital cardiac arrest, in subjects with or without early-onset.
Ventilation protocol. Ventilation protocol. The PEEP group raised peak inspiratory pressure (PIP) through 5-cm H2O PEEP increments every 2 min while keeping.
A: Work of breathing before and after nebulized terbutaline delivered via standard nebulization method versus delivered during continuous positive airway.
Sequence plot visualizing the development of symptom frequency for the cohort at the individual level between 2006 and Sequence plot visualizing.
The changes in peak flow and inspiratory time between a minimum rise time (first 2 breaths) and a maximum rise time (last 2 breaths), with the Servo-i.
Representative tidal volume (VT) and breathing frequency (f) patterns of subjects with COPD and normal subjects during cardiopulmonary exercise testing.
Experimental setup. Experimental setup. Each tested ventilator was connected to the TTL test lung via a ventilator circuit. An oxygen analyzer, a pressure.
An artificial neural network: a multilayer perceptron.
Progression of spontaneous breathing trials administered during inspiratory muscle strength training study interventions. Progression of spontaneous breathing.
For inspiratory load compensation testing, this threshold positive expiratory pressure (PEP) training device was inverted and connected to a respiratory.
Difference between mid-frequency ventilation (MFV), volume control continuous mandatory ventilation (VC-CMV), and pressure control CMV (PC-CMV) when frequency.
A: Comparison of pediatric lung transplant survival between different age groups. A: Comparison of pediatric lung transplant survival between different.
Basic setup for high-flow nasal cannula oxygen delivery.
Percent of extremely-low-birth-weight (ELBW) babies alive and off mechanical ventilation at 7 days, and median days on mechanical ventilation for ELBW.
Fentenyl and lorazepam use for the first 5 d of ventilatory support are presented. Fentenyl and lorazepam use for the first 5 d of ventilatory support.
Minute-by-minute means of breathing variables during the spontaneous breathing trial for the groups of subjects with trial success (n = 32) and failure.
Representative waveforms for each of the devices tested from which the oscillatory f was counted. Representative waveforms for each of the devices tested.
Time taken to perform the Glittre activities of daily living (Glittre ADL) test by severity of COPD obstruction according to Global Initiative for Chronic.
Mean nasopharyngeal pressure during high-flow oxygen therapy, with mouth open or closed. Mean nasopharyngeal pressure during high-flow oxygen therapy,
Presentation transcript:

Likert-scale agreement ratings regarding the use of extubation readiness parameters by pediatric critical care physicians. Likert-scale agreement ratings regarding the use of extubation readiness parameters by pediatric critical care physicians. There is a statistically significant difference in the responses: P < .001 via the Friedman 2-way analysis of variance by rank. P0.1 = airway-occlusion pressure 0.1 s after the start of inspiratory flow. Maroun J Mhanna et al. Respir Care 2014;59:334-339 (c) 2012 by Daedalus Enterprises, Inc.