UOG Journal Club: March 2012

Slides:



Advertisements
Similar presentations
UOG Journal Club: November 2011 Ultrasound prediction of miscarriage
Advertisements

UOG Journal Club: November 2012
Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium.
UOG Journal Club: September 2012 Perinatal outcome in women treated with progesterone for the prevention of preterm birth: a meta-analysis Sotiriadis A,
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
15 de Abril de A Meta-Analysis is a review in which bias has been reduced by the systematic identification, appraisal, synthesis and statistical.
UOG Journal Club: January 2013
Imaging of the pelvic floor: Ultrasound and MRI
UOG Journal Club: April 2013 Intrapartum transperineal ultrasound assessment of fetal head progression in active second stage of labor and mode of delivery.
Quantifying of avascular necrosis of femoral head The clinical problem Determining the risk of femoral head collapse in a patient with AVNFH.
Pr MEDJTOH DR BENLAHARCHE
UOG Journal Club: August 2011
Analysis of Intra-observer's Repeatability in Retinopathy's Classification of patients with, both, Clear and Yellow IOL's implantation INTRODUCTION METHODS.
UOG Journal Club: July 2013 Intrafetal laser treatment for twin reversed arterial perfusion sequence: cohort study and meta-analysis G. Pagani, F. D’Antonio,
Intravoxel Incoherent Motion Imaging in Locally Advanced Rectal Tumours Dr S J Doran Department of Physics University of Surrey S 1 Department of Physics,
INTEROBSERVER AND INTRAOBSERVER VARIABILITY IN THE C-EOS. COMPARISON BETWEEN EXPERIENCED SPINE SURGEONS AND TRAINEES. María del Mar Pozo-Balado, PhD José.
UOG Journal Club: April 2014 Comparison of vaginal mesh repair with sacrospinous vaginal colpopexy in the management of vaginal vault prolapse after hysterectomy.
UOG Journal Club: April 2016 Impact of adding a second layer to a single unlocked closure of a Cesarean uterine incision: randomized controlled trial G.
OBJECTIVE INTRODUCTION Emergency Medicine Milestones: Longitudinal Interrater Agreement EM milestones were developed by EM experts for the Accreditation.
UOG Journal Club: January 2016 Clinical implementation of routine screening for fetal trisomies in the UK NHS: cell-free DNA test contingent on results.
UOG Journal Club: March 2016 Prediction of large-for-gestational-age neonates: screening by maternal factors and biomarkers in the three trimesters of.
UOG Journal Club: July 2016 Ability of a preterm surveillance clinic to triage risk of preterm birth: a prospective cohort study J Min, HA Watson, NL Hezelgrave,
UOG Journal Club: June 2016 Single deepest vertical pocket or amniotic fluid index as evaluation test for predicting adverse pregnancy outcome (SAFE trial):
UOG Journal Club: February 2017
UOG Journal Club: February 2016
Clinical practice involves measuring quantities for a variety of purposes, such as: aiding diagnosis, predicting future patient outcomes, serving as endpoints.
UOG Journal Club: January 2017
UOG Journal Club: April 2016
UOG Journal Club: August 2017
UOG Journal Club 1: September 2016.
UOG Journal Club: July 2016 Ability of a preterm surveillance clinic to triage risk of preterm birth: a prospective cohort study J Min, HA Watson, NL Hezelgrave,
UOG Journal Club: January 2016
UOG Journal Club: March 2016
UOG Journal Club: June 2016 Single deepest vertical pocket or amniotic fluid index as evaluation test for predicting adverse pregnancy outcome (SAFE trial):
UOG Journal Club: July 2017 Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leimyomas in women of reproductive.
Karl Oliver Kagan and Jiri Sonek
UOG Journal Club: October 2016
Measures of Agreement Dundee Epidemiology and Biostatistics Unit
Brain imaging prior to lung cancer resection
UOG Journal Club: May 2017 Increased nuchal translucency thickness and risk of neurodevelopmental disorders S.G. Hellmuth, L.H. Pedersen, C.B. Miltoft,
UOG Journal Club: May 2017 Increased nuchal translucency thickness and risk of neurodevelopmental disorders S.G. Hellmuth, L.H. Pedersen, C.B. Miltoft,
2D/3D EOS imaging versus standing long leg x-ray in lower limb clinical assessment - inter-observer and intra-observer reliability Melinda Hau, Dipen Menon,
UOG Journal Club: January 2018
UOG Journal Club: January 2018
UOG Journal Club: December 2017
Understanding Standards Event Higher Statistics Award
Practical Applications:
UOG Journal Club: April 2017
Stats Club Marnie Brennan
UOG Journal Club: December 2016
UOG Journal Club: July 2012 Maternal hemodynamics at 11–13 weeks’ gestation and risk of pre-eclampsia A. Khalil, R. Akolekar, A. Syngelaki, M. Elkhouli.
UOG Journal Club: September 2011
Comparison of corneal powers obtained from four different devices
UOG Journal Club 1: September 2016.
Fetal Medicine Foundation fetal and neonatal population weight charts
Natalie Robinson Centre for Evidence-based Veterinary Medicine
UOG Journal Club: August 2018
CLICK TO GO BACK TO KIOSK MENU
UOG Journal Club: October 2018
UOG Journal Club: August 2013
UOG Journal Club: July 2017 Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leimyomas in women of reproductive.
UOG Journal Club: December 2018
UOG Journal Club: January 2019
Hale GÖKSEVER ÇELİK, Engin ÇELİK, Gökhan YILDIRIM
UOG Journal Club: March 2019
UOG Journal Club: April 2019
TRANSVAGINAL CERVICAL LENGTH AND MODIFIED BISHOP SCORE IN PREDICTION OF SUCCESSFUL LABOUR INDUCTION IN POSTDATE PREGNANCIES Soe Kyaw Kyaw, Ei Shwe Syn,
UOG Journal Club: February 2012
UOG Journal Club: September 2019
UOG Journal Club: October 2019
Presentation transcript:

UOG Journal Club: March 2012 Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor E. A. Torkildsen, K. Å. Salvesen and T. M. Eggebø Volume 39, Issue 3, Date: March 2012, pages 310–315 Journal Club slides prepared by Dr Aly Youssef (UOG Editor for Trainees)

Background Transperineal ultrasound (TPU) can assess fetal head descent before and during labor The literature is sparse on this subject, and there is no agreement regarding the superiority of 3D versus 2D ultrasound to assess fetal head descent Although 2D and 3D transperineal ultrasound in the labor ward are reproducible and repeatable techniques, the intermethod agreement between 2D and 3D techniques has not been investigated

Objective: to study intraobserver repeatability and Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Objective: to study intraobserver repeatability and intermethod agreement between 2D and 3D ultrasound in assessing fetal head descent during the first stage of labor

Two transperineal ultrasound (TPU) parameters Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Two transperineal ultrasound (TPU) parameters were assessed in the study Head–perineum distance (Eggebø UOG 2006) The shortest distance between the outer limit of the fetal skull and the perineum Assessed in a transverse view Angle of progression (Barbera UOG 2009) The angle between the pubic symphysis and a line tangential to the fetal skull Assessed in a mid-sagittal view

(one volume acquired and analyzed later 3 times for each parameter) Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Patients and Methods 106 primiparous women with a live singleton term fetus in cephalic presentation and a diagnosis of prolonged first stage were included in the study Women were examined in the lithotomy position, with empty bladder, after rupture of membranes and between contractions For each woman both the “angle of progression” and “fetal head–perineum distance” were assessed using two different methods of acquisition 2D (3 acquisitions) 3D (one volume acquired and analyzed later 3 times for each parameter) All volumes and images were obtained and stored by one operator without measured values, and all 2D and 3D measurements were later performed by another operator blinded to clinical assessment and labor outcome

Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Statistical analysis Intraobserver repeatability Intermethod agreement (2D–3D) Was expressed as: the difference between the highest and lowest measurements the intraclass correlation coefficient (ICC) the repeatability coefficient (the range within which two measurements by the same observer will fall for 95% of subjects) Was performed using: the mean of 3 measurements for each technique Intermethod agreement was expressed using the two-way random effects ICC Cohen’s kappa was used to assess agreement for categorical data In addition, linear regression analysis was performed to investigate the association between angle of progression and fetal head–perineum distance (expressed using the Pearson correlation coefficient – “r”) 6

Results: Intraobserver repeatability Repeatability coefficient (mm) Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Results: Intraobserver repeatability Fetal head–perineum distance 2D 3D Mean measurement (mm) 40.1 39.3 Repeatability coefficient (mm) ± 4.1 ± 1.7 ICC (95% CI) 0.94 (0.92–0.96) 0.99 (0.99–1.00) Angle of Progression 2D 3D Mean measurement (º) 108.7 111.0 Repeatability coefficient (º) ± 6.7 ± 5.7 ICC (95% CI) 0.91 (0.87–0.93) 0.94 (0.91–0.96) ICC, intraclass correlation coefficient

Results: Intermethod agreement Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Results: Intermethod agreement Fetal head–perineum distance Angle of progression ICC (95% CI) 0.95 (0.93–0.97) 0.93 (0.89–0.95) Intermethod 95% limits of agreement -5.8 to +7.2 mm -8.9º to 13.7º Mean 2D–3D difference 0.7 mm 2.4º Cohen’s kappa (95% CI) 0.85 * (0.75-0.95) 0.79 † (0.68-0.91) ICC, intraclass correlation coefficient * Using 40 mm as a cut-off level † Using 110º as a cut-off level 8

Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Results: Bland–Altman plots of intermethod agreement between 2D and 3D measurements angle of progression There was a significant, albeit small, mean difference over the range of the measured values for both fetal head–perineum distance and angle of progression.

Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Results: Association between angle of progression and fetal head–perineum distance 2D: r=−0.72 The association was significant at the 0.01 level for both the 2D (r=0.72) and 3D (r=0.71) scan methods r = Pearson correlation coefficient

Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Discussion Both intraobserver repeatability and intermethod agreement between 2D and 3D acquisitions were good The results suggest that 2D and 3D ultrasound might be used interchangeably in fetal head descent assessment in labor The intraobserver repeatability was slightly better in 3D than 2D acquisitions The association between angle of progression and fetal head–perineum distance was good for both 2D and 3D ultrasound

Strength of the study Weakness Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Strength of the study Inclusion of a large, homogeneous and well-defined population Weakness Variation in 2D measurements was analyzed using three different acquisitions, while for 3D measurements the same acquired volume was uploaded three times Possible bias due to the performance of the 3D invariably after the 2D evaluation which might have been the reason of wider angle (mean difference 2.4º) and shorter distance (mean difference, 0.7 mm) in 3D measurements observed in the study. However, the differences were small and probably lacking clinical importance 12

2D and 3D ultrasound methods might be used interchangeably Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor Torkildsen et al., UOG 2012 Conclusion The intraobserver repeatability and agreement between 2D and 3D ultrasound assessment of fetal head descent in labor is good 2D and 3D ultrasound methods might be used interchangeably These results may not be applicable to the second stage of labor where further studies are necessary 13