OL 750 Spectroradiometer & Linear Spectral Transmission Measurements

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

OL 750 Diffuse Spectral Reflectance Measurement System
A Guide to Spectroradiometry
Spectral Resolution and Spectrometers
Advanced Spectroscopy 1. General Aspects. Revision 1. What is the difference between absorption and emission of radiation?  Abs. – uptake; Em. - release.
Spectral Resolution and Spectrometers A Brief Guide to Understanding and Obtaining the Proper Resolution of the 785 Raman System.
7. Beer’s Law and It’s Implications for Instrument Construction.
Source Measurement The most common measurements of sources include:  Radiance - Light emitted in a particular direction  Irradiance – Light falling onto.
OL 750 Measurement Systems
Prismswww.edmundoptics.com Right AngleEquilateralPentagonalDove.
Part IV: Optical Spectroscopy of Solids
Interference and Diffraction
Overlapping Orders Douglas A. Skoog and James J. Leary, Principles of Instrumental Analysis, Saunders College Publishing, Fort Worth, d(sin  + sin.
OL Series 754 Portable UV-VIS-NIR Spectroradiometer The OL 754 Portable UV-Visible-NIR Spectroradiometers are a series of compact, portable, double monochromator.
Are you getting the concept? Calculate D a, D l, R d and s g for 1 st order diffraction under optimal conditions for the indicated 0.5 m grating with 100.
Source lens Entrance slit Exit slit width,  (mm) grating Concave mirrors Focal Plane Focal Length, F (mm)
Astronomical Spectroscopy
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Ultraviolet – Visible Spectrophotometer. What is UV – Vis spectroscopy? Ultraviolet – visible spectroscopy is a measure of the absorbance of radiation.
1 Components of Optical Instruments, Cont… Lecture 7.
HBD Transmission Monitor: Update on Assembly & Testing HBD Working Group Meeting 8/29/06 B. Azmoun Brookhaven National Lab.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Transmittance Measurement Presented by Dr. Richard Young VP of Marketing & Science Optronic Laboratories, Inc.
The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer for JWST Martyn Wells MIRI EC & UKATC.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
The Future of NVIS Display Measurement ALI Advanced Seminar, 2006Optronic Laboratories Dr. Richard Young Optronic Laboratories, Inc.
18 October Observational Astronomy SPECTROSCOPY and spectrometers Kitchin, pp
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
Astronomical Spectroscopy Notes from Richard Gray, Appalachian State, and D. J. Schroeder 1974 in “Methods of Experimental Physics, Vol. 12-Part A Optical.
Latest Advances in Spectroradiometric Measurement Systems for Night Vision Compatible Displays Latest Advances in Spectroradiometric Measurement Systems.
PERKIN-ELMER MODEL 200 UV-VIS SPECTROPHOTOMETER OPERATING INSTRUCTIONS.
Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric Measurement System Optronic Laboratories Inc. OL Series 750 Automated Spectroradiometric.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
OL Series 750 Automated Spectroradiometric Measurement System The OL Series 750 is an extremely versatile spectroradiometric measurement system capable.
Micro-mirror Micromechatronics System FH AACHEN
Spectrophotometry.
1 Reflected Solar Calibration Demonstration System - SOLARIS K. Thome, D. Jennings, B. McAndrew, J. McCorkel, P. Thompson NASA/GSFC.
HBD Gas and QE Monitoring Craig Woody BNL HBD Working Group Meeting October 19, 2005.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
OL 750 Measurement Systems OL 750 Measurement Systems Optronic Laboratories, Inc.
Spectrophotometer.
Recent Solar Irradiance Data From SBUV/2 and OMI Matthew DeLand and Sergey Marchenko Science Systems and Applications, Inc. (SSAI) SOLID WP-2 Workshop.
Molecular Luminescence Spectroscopy
Scisat Test Readiness Review MAESTRO Evaluation and Verification Tests University of Toronto 29 January 2003.
Laser Spectroscopy/SJX Chap. 4 Components of Spectroscopic Instruments 1 In this chapter we discuss basic spectroscopic instruments and techniques employed.
Transmission Measurement Basic Outline. Transmission Curve Describes the percentage of a signal that is transmitted through an object (filter) over a.
Instrumental Analysis
GS-1150 HANDHELD SPECTROPHOTOMETER. ABOUT GAMMA SCIENTIFIC With over 50 years of experience in developing commercial light measurement instruments, Gamma.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Chem. 133 – 3/16 Lecture.
Simple Double Beam Spectrometer
Diffraction Gratings.
UNIT-3 ADVANCES IN METROLOGY
Date of download: 10/12/2017 Copyright © ASME. All rights reserved.
Spectrophotometer - Visible Type Spectro - photometer consists of two instruments : Spectrometer   Photometer  Spectrometer   for producing light.
Chapter 3. Components of Optical Instruments
Analyzing and Correcting Stray Light Using LensMechanix
Measurements involving light –A Basic Principles and Instrumentation
عنوان آزمايشگاه: اسپكتروفتومتري
SPECTROPHOTOMETER UV 2080 PLUS DOUBLE BEAM
Changchun Institute of Optics Fine Mechanics and Physics
Instrumental Analysis
High Accuracy UV-VIS Spectroradiometer ( nm)
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
OL 750 Measurement Systems
Instrumentation for UV and visible absorption
Palm-Top USB Radiometer/Photometer
Presentation transcript:

OL 750 Spectroradiometer & Linear Spectral Transmission Measurements Optronic Laboratories, Inc.

About Optronic Laboratories, Inc. Optronic Laboratories, Inc. was established in 1970 by two eminent researchers at NIST (then NBS). Facilities were modeled after NIST, and Optronic Laboratories, Inc. achieved a worldwide reputation for excellence in light measurement and calibration. Continuing to work closely with NIST, the development of new instruments and techniques at Optronic Laboratories, Inc. constantly improves the accuracy and precision of light measurement.

About Optronic Laboratories, Inc. In 1998, Optronic Laboratories, Inc. moved into its new 25,000 square foot purpose-built facility, consolidating and expanding production, R & D and calibration facilities

The OL Series 750 Monochromators The heart of any spectroradiometric system is the monochromator, but… It must give the right bandpasses – Too large and spectra are distorted Too small and signals are low It must give high spectral purity (low stray light) so only the wavelength of interest is detected

The OL Series 750 Monochromators Available in single and double (shown) versions F/4 optics for high throughput Very low stray light Numerous special features for most accurate results

The OL Series 750 Monochromators Large range of gratings available Optimised for high efficiency Optimised for wide wavelength range Optimised for high resolution Tri-grating mounts change gratings automatically

The OL Series 750 Monochromators Range of Plug-in input accessories Choppers (shown) for IR detectors Automatic control of chopper speed and “open” position stop Filter-wheel for input attenuation or filtering

The OL Series 750 Monochromators Fully automated 11 position blocking-filter wheel Includes SHUT position for dark current readings Optimised filters for widest wavelength range Blocking-filter wheel changes filters automatically

The OL Series 750 Monochromators Light passes into the monochromator through the entrance slit, then onto the first collimating mirror.

The OL Series 750 Monochromators Collimated (parallel) light is directed onto the grating.

The OL Series 750 Monochromators The grating diffracts the light, sending each wavelength off at a different angle. The desired wavelength is collected by the first focussing mirror….

The OL Series 750 Monochromators …which focuses it at the middle slit. A second collimating mirror collects this beam…

The OL Series 750 Monochromators …and collimates it onto a second grating. Since the second grating is linked to the first, they are at the same angle and hence the same wavelength.

The OL Series 750 Monochromators This second grating acts like the first, but the spectral purity is increased by many decades.

The OL Series 750 Monochromators The pure monochromatic light, at the wavelength desired, is then focussed onto the exit slit and emerges from the monochromator

Transmission Measurements For transmission measurements a light source at the entrance of the OL 750 creates monochromatic light at the exit

The OL Series 740-20 Light Sources Single and double lamp versions UV lamp 200nm to 400nm Tungsten lamp 250nm to 2500nm Glowbar 1000nm to 30000nm

The OL Series 740-20 Light Sources Optics match the OL Series 750 Monochromators Easy switching from one source …

The OL Series 740-20 Light Sources Optics match the OL series 750 monochromators Easy switching from one source … …to the other Fully automated switching available

The OL 750 + OL 740-20 200 to 30,000 nm coverage monochromatic light prevents sample heating Suits a very wide range of standard OL accessories Suits many existing and future applications

Transmittance Measurement Transmittance can be regular (like a window) or diffuse (like paper) Optronic Laboratories, Inc. manufacture a wide range of accessories for regular and diffuse transmittance To illustrate a regular transmittance measurement system, we will use the OL Series 740-73 Transmittance Attachment

The OL Series 740-73 After a 100% scan (with setup as shown), the sample is placed in the beam The OL 740-73 collimates light through the sample compartment and refocuses onto the detector Sample Collimated light Detector

The OL Series 740-73 The ratio of a scan with the sample in place to the 100% scan is the transmittance of the sample

Other transmittance accessories are available to cover the range The OL 740-73 + OL 750 + OL 740-20 When the system is assembled, the transmission of a sample can be measured up to 14,000 nm Other transmittance accessories are available to cover the range 200 nm to 30,000nm

More Information The system illustrated represents just a few of the accessories from Optronic Laboratories, Inc. For more information: Visit our website at www.olinet.com Call 407-422-3171 to Contact an Application Engineer