Smart Lipid Management - QDx Lipidcheck TM
Lipid Analyzer and Handheld meter Analyzers used in labs Handheld Meters used by clinicians
For monitoring Lipid levels of patients
Feature and Benefits TC and HDL ratio for TC/TG/HDL • 6 Parameters: TC, TG,HDL, LDL, HDL and LDL ratio, TC and HDL ratio • Finger prick sampling: 45µL of whole blood • Rapid and accurate results: 3 separate sample well for TC/TG/HDL • Portable, palm sized: Easy to carry • Ideal for clinicians: Quick results in 3 minutes, immediate treatment
QDx Lipidcheck competition Against feature – Meters QDx Lipidcheck TM feature – Against Meters QDx Lipidcheck Lipidocare Cholestech LDX Affinion Lipidpro Marketers DiaSys SD Biosensor Alere Alere Infopia Measuring Range (mg/dL) TC 100-400 TG 50-600 HDL 20-80 TC 100 450 TG 45-650 HDL 25-95 TC 100-500 TG 45-650 HDL 15-100 TC 100-500 TG 45-650 HDL 15-100 TC 100-400 TG 80-600 HDL 25-80 Sample Volume 45 µL 40 µL 40 µL Assay time 3 Minutes 3 Minutes 5 Minutes 5 Minutes 3 Minutes Shelf life 12 Months 12 Months 12 Months 12 Months 12 Months
Comparison of QDx Lipidcheck with SD Biosensor TM with SD Biosensor Features/ Benefits QDx Lipidcheck TM SD Lipidocare Direct use of Pipette/ Ease of Use • QDx Lipidcheck TM provided 15µl pipette inside the kit. Directly attach with pipette tips and use. Easy to use • SD Lipidocare has capillary method for collection of blood. Plunger need to be attached to capillary till mark. If not attached properly then this may allow improper blood collection
Comparison of QDx Lipidcheck with SD Biosensor TM with SD Biosensor Features/ Benefits QDx Lipidcheck TM SD Lipidocare 15µl of Pipette/ No tip rejection • QDx Lipidcheck TM two step procedure for smooth collection blood and do not allow any rejection of strip. • SD Lipidocare has capillary method for collection of blood. Small air bubble result in rejection of strip 15µl pipette tip/ Easily available Provided with every kit Capillary provided with every kit • QDx Lipidcheck TM provide 10 tips with every kit. Universal 15µl pipette tip can be used • SD Lipidocare provided capillary tube with every kit. Dedicated capillaries can only used to perform the test
Comparison of QDx Lipidcheck with SD Biosensor TM with SD Biosensor Features/ Benefits QDx Lipidcheck TM SD Lipidocare 3 different slots of parameter/ Equal distribution of blood in every port • QDx Lipidcheck TM has 3 different slots for testing parameters. Blood is equally dispensed in each port. 3 parameter (TC/Tg/HDL) are optically read in instrument. • SD Lipidocare has only one port, equally blood distribution is ambiguous for all parameter. Optically reading or calculation of parameters are unclear
with Infopia LipidPro Comparison of QDx Lipidcheck Features/ Benefits TM with Infopia Features/ Benefits QDx Lipidcheck TM Infopia LipidPro Direct use of Pipette/ Ease of Use • QDx Lipidcheck use TM provided 15µl pipette inside the kit. Directly attach with pipette tips and use. Easy to • Infopia LipidPro has capillary method for collection of blood. Manual observation required to avoid any error
with Infopia LipidPro Comparison of QDx Lipidcheck Features/ Benefits TM with Infopia Features/ Benefits QDx Lipidcheck TM Infopia LipidPro 15µl of Pipette/ Easy blood collection. • QDx Lipidcheck TM two step procedure for smooth collection blood and do not allow any rejection of strip. • Infopia LipidPro has capillary method for collection of blood. Small air bubble result in rejection of strip 15µl pipette tip/ Ease of available Provided with every kit Capillary provided with every kit • QDx Lipidcheck TM provide 10 tips with every kit. Universal tips of 15 µl can be used • Infopia LipidPro provided capillary tube with every kit. Only dedicated capillaries can be used which are not easily available
with Infopia LipidPro Comparison of QDx Lipidcheck Features/ Benefits TM with Infopia Features/ Benefits QDx Lipidcheck TM Infopia LipidPro Use of pipette/ Easy to dispense blood in sample well • QDx Lipidcheck TM uses pipette, Blood is easily dispensed in sample wells • Infopia LipidPro use capillary which is needed to be pressed against each well to dispense required volume of blood
Thanks