Brian Yee, W6BY Microwave Update 2010 Cerritos, CA

Slides:



Advertisements
Similar presentations
Envelope Detector Conventional DSB-AM signals are easily demodulated by an envelope detector It consists of a diode and an RC circuit, which is a simple.
Advertisements

Chapter Six: Receivers
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
Principles & Applications Communications Receivers
Chapter 4 Problems ECET 214 Prof. Park NJIT.
Spectrum analyser basics Spectrum analyser basics 1.
Spectrum Analyzer. Another Oscilloscope??? Like an oscilloscope Oscilloscope in time domain Spectrum analyzer in frequency domain (selectable)
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
Chapter 3 – Angle Modulation
Electronics Principles & Applications Sixth Edition Chapter 12 Communications (student version) ©2003 Glencoe/McGraw-Hill Charles A. Schuler.
McGraw-Hill © 2008 The McGraw-Hill Companies Inc. All rights reserved. Electronics Principles & Applications Seventh Edition Chapter 12 Communications.
IT-101 Section 001 Lecture #15 Introduction to Information Technology.
COMMUNICATION SYSTEM EECB353 Chapter 2 Part IV AMPLITUDE MODULATION Dept of Electrical Engineering Universiti Tenaga Nasional.
Octiv RF Power monitoring technology “. Talk Outline Impedans VI technology Introduction to power monitoring Need for VI Probes Why IV sensors are needed.
SADARS An introduction to RF Spectrum Analysers With acknowledgements to Wikipedia.
Spectrum Analyzer. INTRODUCTION  A spectrum in the practical sense is a collection of sine waves, when combined properly produces the required time domain.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Software Defined Radio
Distributor URL here  TDS2000 and TDS1000 Series Digital Storage Oscilloscopes Colorful Performance at a Black and White Price Power and precision: with.
THE RADIO OF THE FUTURE Natarajan.P No. 17 S7 Electronics & Comm. PTDC College of Engineering, Thiruvananthapuram.
Generation of FM Two methods of FM generation: A. Direct method:
Electronics Principles & Applications Fifth Edition Chapter 12 Radio Receivers ©1999 Glencoe/McGraw-Hill Charles A. Schuler.
Amplitude Modulation 2.2 AM RECEIVERS
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
SPECTRUM ANALYZER 9 kHz GHz
Some observations on phase noise from local oscillator strings. By KØCQ Dr. Gerald N. Johnson, retired P.E.
SPECTRUM ANALYZER Lee Garlock, KD4RE Assisted by Ron Payne, WA6YOU A Vienna Wireless Society Presentation THE APPLICATIONS in AMATEUR RADIO by.
RADITEK inc RADITEK-RFTS-M1-L21WORLD HQ: 1702L Meridian Ave. Suite 127, San Jose, Ca 95125, U.S.A. Tel: (408) FAX: (408) WEB:
MDO4000C Series vs. Regular Scope FFTs Competitive Fact Sheet Benefits: ~20dB better dynamic range than a scope FFT RF support.
Harmonic Mixers for Spectrum Analyzers
RADIO RECEIVERS.
April 12 | Comparison of Sophisticated Synthesizer Concepts and Modern Step Attenuator Implementations | 2 Comparison of Sophisticated Synthesizer Concepts.
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
FUNCTION GENERATOR.
Amplitude Modulation Part 2 - AM RECEPTION.  To define AM demodulation  To define and describe the receiver parameters  To describe the operation of.
IT-101 Section 001 Lecture #15 Introduction to Information Technology.
Texas Instruments Introduction to Direct RF Sampling
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
MECH 373 Instrumentation and Measurements
Radar System Components and System Design
Demodulation/ Detection Chapter 4
A High-Dynamic-Range W-band
Chapter 3 ANGLE MODULATION
CHAPTER 3 Frequency Modulation
Improving Tuned Circuits
Powerful Performance from Bench to Field
HDO4000 /HDO4000-MS Series Manufacturers Test Equipment Components
Overview Communication is the transfer of information from one place to another. This should be done - as efficiently as possible - with as much fidelity/reliability.
Generation & Detection of FM Application of FM
Analog Operating Modes
Amplitude Modulation 2-3 AM RECEIVERS
The Hardware of Software Defined Radios
Principles & Applications
Programmable Logic Controllers (PLCs) An Overview.
Chapter Five: Transmitters
Phase Noise… How much is too much?
Terry Cotter LO/IF Group Leader
Microwave Synthesisers
DISPLAY AND RECORDING DEVICES-unit 2 -CRO
Phase Noise… How much is too much?
TRANSMITTERS AND RECEIVERS
8.5 Modulation of Signals basic idea and goals
Transmitters Advanced Course requires a detailed knowledge of Transmitters and Receivers This session covers Transmitter Block Diagrams, Oscillators and.
AM-7026 Down Converter-Receiver
Receiver Architecture
Module V Wave Analyzers
Technician License Course Chapter 3
Signal level Meter THROW DOWN
Phase Noise… How much is too much?
Presentation transcript:

Brian Yee, W6BY Microwave Update 2010 Cerritos, CA Spectrum Analyzers Brian Yee, W6BY Microwave Update 2010 Cerritos, CA This talk is an introduction to the basic design of spectrum analyzers and a survey of representative units available to the average or above average ham.

Presentation Outline Basic design and evolution Applications Overview of available models Issues for prospective buyers And…

Basic Concepts – Key Components MIXER RF IN Display Detector IF A simple swept receiver with a visual display SWEEP OSCILLATOR The most rudimentary form of spectrum analyzer is the same as a superhetrodyne receiver, except the local oscillator is replaced by a sweeping oscillator. Early spectrum analyzers used mechanical methods to sweep the LO, and they were limited to only a few kilohertz of sweep width. A brief history of some spectrum analyzer developments can be found at: http://www.hpmemory.org/wb_pages/wall_b_page_04.htm

Some Refinements… MIXER RF IN Display Problems with this approach: FILTER FILTER Detector Problems with this approach: Limited frequency range Can’t look at low frequencies Spurious signals show up Narrow sweeps difficult SWEEP OSCILLATOR Simple spectrum analyzers are limited by the frequency range of the sweep oscillator, unless they use harmonic mixing. Harmonic mixing can introduce spurs or false signals since the front end is not selective. Also, a free running sweep oscillator is not frequency accurate, especially during narrow sweeps. Analog displays also suffer from flicker and distortion.

More Refinements RF IN MIXER Display Better spur rejection Resolution bandwidth Video bandwidth RF IN MIXER FILTER Display FILTER FILTER Detector SWEEP OSCILLATOR/ SYNTHESIZER Better spur rejection Better frequency accuracy By adding a tracking front end filter, spurious signals are nearly eliminated. Replacing the free running sweep oscillator with a synthesized sweep oscillator greatly improves frequency accuracy. The technique commonly used in modern spectrum analyzers is called “lock and roll”, meaning the sweep is locked using synthesis techniques at the beginning of the sweep and then the oscillator is allowed to sweep. During narrow sweeps, the local oscillator is completely synthesized for greatest frequency accuracy. Variable filters before and after the detector improve the resolution of the displayed signals.

High-end approach 2 - 6 GHz Resolution Bandwidth 3.6 GHz 9KHz – 2 GHz 3.3 GHz OSC Resolution Bandwidth 3.6 GHz 9KHz – 2 GHz MIXER 321.4 MHz 21.4 MHz MIXER LP FILTER FILTER MIXER FILTER RF IN FILTER 300 MHz OSC 2 – 22 GHz MIXER 321.4 MHz FILTER FILTER FILTER Display The trend in later model spectrum analyzers was to use a much more sophisticated front end. These tended to use a high frequency first IF which was downconverted to a mid-frequency second IF, and finally a low-frequency IF. This triple-conversion approach improves selectivity. The purely analog display is replaced by an A/D converter and digital storage. This eliminates flicker and enables accurate measurements using cursors and markers. Also a limited amount of signal processing is possible, such as averaging, peak search, and so on. Since all oscillators are locked to a precision frequency reference, the spectrum analyzer can accurately measure the frequency of displayed signals. Since these analyzers use microprocessors, these analyzers can be controlled remotely. Detector SWEEP OSCILLATOR/SYNTH Video Bandwidth 2 - 6 GHz

Applications Checking the power of amplifiers (with the proper pad) Checking for harmonics Phase noise measurement Modulation measurement Channel power measurement

Tektronix 7Lxx, 1Lx Plug-ins In the beginning… The old military units with mechanical sweep oscillators will not be discussed here since other than for historical purposes they are not suitable for modern use. Some early spectrum analyzers were plug-ins for oscilloscopes. This was a natural fit since oscilloscopes had most of the basic elements needed for a spectrum analyzer. The 1Lxx series was a popular plug-in for the Tektronix 545 series oscilloscopes. In the later 7000 series Tektronix scopes, the 7Lxx series was employed. The 7000 series Scopes were some of the first to have digital readouts on the display.

Tek 7Lxx Series

Tektronix 49x Series – 22 GHz 492 popular, lots available, mm-wave mixers available, digital/analog display Tektronix introduced a line of portable spectrum analyzers, starting with the 491, and later with the 492 and 494 series. The 492 and 492 series had much better accuracy, digital displays and used microprocessor control. These units could also measure millimeter wave signals up to 300 GHz. 494AP top of the line Some limited-frequency range units (496, 492P’s)

Tektronix 27xx Series – 1.8 GHz Primarily made for field use, service shops and CATV servicing

Tektronix 275x Series – 22+ GHz Rack mount variation of 494AP, some models mm-wave capable

Tektronix 279x – 26 GHz Nice… Tektronix continued to improve on its line of portable spectrum analyzers.

Tektronix 2782/4 – 40 GHz Even nicer… CRT has color LCD shutter 2782 has 33 GHz range, 2784 has 40 GHz range MM-wave operation possible with internal duplexer Expensive This was Tektronix’ top of the line portable spectrum analyzer. These used proprietary liquid crystal shutters to produce color displays. The 2782 could measure to 33 GHz, and with slightly different firmware could be extended to 40 GHz (2874). Both analyzers could measure up to 300 GHz with external mixers. These are still expensive, hard to find and very desirable.

HP 851A Display unit shown, RF unit goes on the bottom. Very basic functionality, but more than 1L20 Back at HP, they were developing a unit called the 851A. These used a 2 to 4 GHz backward wave oscillator that was revolutionary because of its wide sweep bandwidth. Previous generations of spectrum analyzers used a tunable first LO followed by a Narrow band sweep oscillator. The 851A could measure up to 12 GHz using harmonic mixing, and to 40 GHz (very high at the time) using external harmonic mixers. The display section is shown here, and there was a separate RF tuning unit.

HP 141T – 18 GHz Nice unit, lots available 3 types of plug-ins up to 18 GHz Uses storage tube A very popular successor to the 851A, and a significant improvement, was the 141T with plug-ins that enabled measurements from the kilohertz range up to 18 GHz, and to 40 GHz with external mixers. This also used harmonic mixing for the microwave bands, and a much improved display and IF system. This series had accessories such as tracking preselectors and different band plug-ins.

HP8557 Several plug-ins available HP also made some low-cost “portable” analyzers that were oscilloscope plug-ins, following the Tektronix trend.

HP 8565A – 22+ GHz Many available Storage display with digital readouts Can use external mixers The 8565A started to use some digital technology, but they were still behind Tektronix in their ability to incorporate a digital display on the CRT.

HP 8569A/B – 22+ GHz Very popular, lots available Can use external mixers Digital storage display, GPIB HP finally started to catch up to Tektronix when it produced the 8569A/B. This is basically the 8565A (same analog circuits) with a digital display GPIB capability.

HP 8568A/B, 8566A/B, 8567A – 22 GHZ+ An industry standard One of the best displays Lots available Serviceable Can use external mixers, auto signal ID HP took a great leap forward when it introduced the 8568A. Now they finally had a high-performance spectrum analyzer with a very nice digital display, superb frequency and amplitude accuracy, and advanced signal measurement capability. These analyzers are still the standard in many EMC and design labs. About a year after the 8568A was released, HP announced the 8566A, which extended frequency coverage up to 22 GHz with the same accuracy and features as the 8568A. The 8566A could measure millimeter wave signals with external mixers, and had the unique (at the time) ability to identify and display only the real signal out of the spurs produced by harmonic mixing.

HP 859x Series Low-end portable Subject to drift Intended for field service market Lots available In the late 80’s, HP came out with a line of low-cost portable analyzers. These analyzers suffered from frequency drift and poor frequency accuracy. Still, HP expanded this line with several models up to 22 GHz. Many of these are available, and still command a relatively high price.

HP 856x Series Many of the features of the 8566 series and more crammed into a portable unit HP later introduced the 856x series of portable spectrum analyzers, and many of these had the same or better performance than the 8566 series of bench analyzers. The high-end models could cover up to 50 GHz, fully preselected, And had millimeter wave capability with external mixers. Many available at high prices. Synthesized Available in several frequency ranges Some can use external mixers Expensive

IFR 1 GHz unit Lots available IFR originally made communications service monitors, but branched out into spectrum analyzers. Some of the service monitors include spectrum analysis capability. IFR later acquired Marconi Instruments, and still produce several of their products.

Advantest 326x, R346x series Nice units, lots of features, hard to get service info Several Japanese manufacturers came out with some nice units, but parts and manuals are hard to come by.

Advantest U36xx Series Microwave units to 26+ GHz

Anritsu MS710A/B/C/D D model can accept either Tek or HP mixers

Anritsu MSxx Series

Others What to look for: Service manual available Physical condition “unobtainium” parts Serviceability Marconi Instek AIL/Eaton Systron Donner Rohde and Schwarz – expensive Wandel & Goltermann Various Chinese makes

Recent advances Smaller units with more capability DSP, more complex measurements Demodulation of various communications formats Better displays Faster speed Interface with other instruments such as power sensors The current improvements in microcontrollers, A/D converters, DSP and displays enable smaller, lighter and more powerful instruments. DSP can replace much of the bulky analog circuits and can process a wider spectrum of signals simultaneously. DSP also enables signals not only to be displayed, but also demodulated and can measure the quality of complex signals.

And…..?

The MUD 2010 Grand Prize!!! 100 KHz to 3 GHz freq. Range 6.5” color TFT 4-hour battery life One-button power measurement Spectrogram USB power sensor support Field strength measurement Much more…