STANDARDISATION, HARMONISATION AND TRACEABILITY

Slides:



Advertisements
Similar presentations
PRINCIPLES OF A CALIBRATION MANAGEMENT SYSTEM
Advertisements

QUALITY CONTROL IN HEMATOLOGY
The 53 rd Annual Meeting of the Japan Diabetes Society Nationwide Surveillance Study on Hemoglobin A1C by JDS in 2009 Katsuhiko Kuwa 1, Masao Umemoto 2,
JCTLM REFERENCE LABORATORY SERVICES Report of WG2 November 14, 2005 _________________________________________.
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
Control of Analytical Variables Dr. Roula Hamid MSc Clin Biochem Central Puplic Health Laboratory QC Chemistry.
1 Introduction to the GUM ( International Guidelines for calculating and expressing uncertainty in measurement) Prepared by Les Kirkup and Bob Frenkel.
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
All you wanted to know about laboratory tests, but were afraid to ask By Dietmar Stöckl STT Consulting The informed patient meeting the laboratory.
OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY ASSURANCE PROCEDURES & ACCREDITATION An Overview OPTIMISING CHEMICAL ANALYSIS FOR THE WFD BY QUALITY.
Laboratory Management - 1
Senior Lecturer in Pathology
Laboratory Information Management Systems (LIMS) Lindy A. Brigham Div of Plant Pathology and Microbiology Department of Plant Sciences PLS 595D Regulatory.
Quality Assurance in the clinical laboratory
Project co- financed by Asean European Committee for Standardization Implementing Agency Project co-financed by European Union Module 7 GMP Workshop Kuala.
Quality Assessment 2 Quality Control.
Melbourne, Australia, November 2011
Introduction to ISO New and modified requirements.
For the CAP Instrumentation and Chemistry Resource Committees
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Quality WHAT IS QUALITY
Metrology Adapted from Introduction to Metrology from the Madison Area Technical College, Biotechnology Project (Lisa Seidman)
Quality Control Lecture 5
PH4705 & ET4305: Measurements Measurement: assign numbers to property of object or event to describe it The absolute true value of a measurement can’t.
Identification of Reference Measurement Laboratories _________________________________________ JCTLM WG-2 Lothar Siekmann Institute of Clinical Biochemistry.
International Scientific Workshop on the Standardization of Genome Amplification Techniques for the Safety Testing of Blood, Tissues and Organs With Regard.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Use of Reference Materials in Medical Testing SLAB 10th Anniversary Celebrations Accreditation Conference 10 th November 2015 Dr Deepani Siriwardhana Senior.
Mauro Panteghini Who, what and when to do in validation/verification of methods.
Metrology for Chemical Analysis
Application of Westgard multi rules in medical laboratories
All you wanted to know about laboratory tests, but were afraid to ask By Dietmar Stöckl STT Consulting The informed patient meeting the laboratory.
1 Analytical Forensic Metrology Analytical Forensic Metrology 4 th International Conference on Forensic Research & Technology September 29, 2015 Jerry.
Clinical Utility of EQA Dr. Angela Amayo UON27/11/2008.
Definitions Purposes Metrology Basics Role of BMET Role CE Documentation Conclusion.
Table 1. The Five Medical Laboratory Case Studies Jan Martin et al. Transnational Evaluation of a New Continuing Professional Development Activity for.
European Diagnostic Manufacturers Association EQA contribution and industry expectations Dr. Claude GIROUD – Chairman Standardization, Quality & Risk Management.
Diagnostic clinical chemistry
Traceability in Chemical Measurement Comparable results are needed in order to avoid duplicating measurements which cost time and money. Comparable results.
T RACEABILITY OF R ECORDS. M EI B ETH S HEPHERD 3 rd Party Assessors Consultants.
Introduction to Quality Assurance. Quality assurance vs. Quality control.
Why you should mind your "P’s and Q’s"
Method Validation-where do I start?
Challenges in Method Validation – A Regulatory Laboratory Perspective
Quality is a Lousy Idea-
CURRENT SITUATION AND PROBLEM OF IQC AND EQC IN INDONESIA
Importance of Reference Material for Assaying Precious Metals as per standards in vogue Pankaj Deshmukh 12th Aug 2017.
QUALITY MANAGEMENT Suzanne Kamel-Mohamed PhD, MBA, MT (ASCP) Associate
Quality Assurance in the clinical laboratory
Institute for Reference Materials and Measurements (IRMM)
Proficiency Testing as a quality improvement tool
CHAPTER 2 Research Methods in Industrial/Organizational Psychology
Laboratory Quality Control
Practical clinical chemistry
Quality is a Lousy Idea-
Maintaining quality data throughout the life of a project
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Choice of Methods and Instruments
Good Laboratory Practices
Introduction To Medical Technology
Introduction To Medical Technology
Quality Control Lecture 3
Thank you to the Congressional Public Health Caucus, which has brought us today to talk about an important issue that affects patient care and treatment,
▪Internal quality control:
Understanding Data Choices, Characteristics, Limitations
Reference Materials Definitions:- Reference material (RM) “Material, sufficiently homogeneous and stable with respect to one or more specified properties',
08/ COMMUTABILiTY.
MEASUREMENT UNCERTAINTY
CPSA 4 Corners Initiative 2018
Presentation transcript:

STANDARDISATION, HARMONISATION AND TRACEABILITY Dr A A KHINE DIVISION OF CHEMICAL PATHOLOGY NHLS TYGERBERG STELLENBOSCH UNIVERSITY Laboratory Management workshop 3-6 June 2019

Good laboratory practice requires Error of measurement must be small enough that a result reflects a patient’s biological condition. Comparable results that are independent of: Where and when a test was performed The measurement procedure used

Total Error Calibration bias to an accepted reference ( and also includes bias from calibrator lot-to-lot variability) Imprecision in a measurement procedure Sample specific influences non-specificity for the measurand interfering substances

Why We Need Comparable Results? If different measurements give different results for the same patient sample: Clinical practice guidelines become less useful. Patients may receive incorrect treatment. Patients may be moving around, thus specimens sent to various labs

Three areas of standardization in the clinical laboratory procedures that are followed before analysis How sample is analysed (test methods used) What calibrator is used and how it is traceable

Standardisation versus harmonisation Standardization: Same method or same instrument used Using calibrator with a traceability ref number Results are uniform among measurement procedures Reporting units are the same Harmonization: Different methods are used but results are not uniform but comparable Reporting units may not be the same originally but conversions help to make comparable (SI units) No reference measurement procedure and no “pure substance” reference material

How To Achieve Comparable Results? Laboratories using a common traceable calibrator or different calibrators with the same traceability ref number Performance is monitored and maintained by surveillance using proficiency testing (PT), external quality assessment (EQA), or a certification program.

Metrological traceability True value is not known unless it is attached to a reference so that value can be assigned is defined as “the property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty”. Traceability is established to SI using a reference calibrator and reference measurement procedure

Metrology traceability chain

COMMUTABILITY ISSUES Commutable means that the ref material reacts with the reagents in the ref method and other methods in the same way that analyte in the patient sample would Thus, values obtained from the calibration material and from native clinical samples have the same relationship across measurement procedures for the same measurand. Ideally a reference material should be validated for commutability against all field methods and types of samples but it is rarely the case Poor commutability means there is matrix effect affecting reaction between reagent and measurand

When there is no or poor commutability A manufacturer uses a “master lot of calibrator” that may be traceable to a non-commutable reference material, then the Traceability chain is broken Even though manufacturers claim traceability, the process fails to provide equivalent results for patient samples when different measurement procedures are used.

Calibration Traceability Does Not Ensure Accuracy for an Individual Patient Sample Measurement procedure may not be specific for the measurand. Measurand may not be well defined. Molecular form(s) of clinical interest Interfering substances present in a patient’s sample may influence the result

Use of a Non-commutable Material for Calibration Will Cause Incorrect value assignment for the manufacturer’s calibrator Incorrect results for patient samples

Calibrators in the routine laboratory A manufacturer's calibrator is proprietary (patented)- intended for use with a specific measurement procedure. It cannot be used with a different manufacturer’s measurement procedure This is because the company has validated its commutability only with their own reagent

Change in Practice Needed In the business of producing and marketing PRM, SRM and TRM, there must be requirement to submit commutability validation against Reference methods Manufacturer’s methods and reagents Routine clinical laboratory procedures and reagents A guideline for validating commutability is available: CLSI C53-A- Characterization and Qualification of Commutable Reference Materials for Laboratory Medicine (2010)

No traceability No reference measurement procedure or No reference material Can there be harmonisation?

Barriers to Harmonization Lack of a systematic process to identify and prioritize measurands Materials labelled as “reference materials” that have not been validated to be commutable for the intended measurement procedures Inadequate definition of the measurand Inadequate analytical specificity for the measurand Lack of systematic procedures to implement harmonization, in particular: When there is no reference measurement procedure When there is no reference material

Initiatives in establishing S and H IFCC has been a key leader in developing science in developing PRMs and RMPs. Many national and international groups are engaged JCTLM (joint committee for traceability in lab measurements) composed of three organizations: International Committee of Weights and Measures International Federation of Clinical Chemistry and Laboratory Medicine International Laboratory Accreditation Cooperation

Functions of JCTLM Maintain the list of reviewed and approved Reference measurement procedures Reference laboratories Reference materials Commutability requirements are being addressed.

Possibilities for consideration: Traceable to an all methods mean (outliers removed) of a panel of patient samples Traceable to a designated measurement procedure (arbitrary, but which has good correlation with clinical outcome)

References Mary Lou Gantzer, PhD, FACB. President, CLSI, CEO, BioCore Diagnostics. Laboratory Standardization: Bringing Order to Chaos Standardization –the theory and practice-Jill Tate, M Panteghini The JCTML- A global approach to promote standardization of clinical laboratory test results Traceability, Reference systems and result comparability- Clin Biochem reviews- 28Aug 2007 ISO 17511

EXERCISE What are the analytes in routine chemistry that have been standardized using both ref material and ref method procedure? What are the analytes that have been standardized through development of primary ref material but not all routine laboratories use the reference method procedure? What are the analytes that have been standardized through development of primary ref material but lacking method standardization? What are the analytes that have not been standardized through both development of primary ref material or method standardization? How has NHLS tried to harmonise the analytes under 2, 3, 4 and 5?