Compact, modular meters for feeders and critical loads

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

Mining Solutions Energy Efficiency Solutions. Challenges to the Mining Industry Need to increase profits and reduce environmental impact Important to.
Multi Functional Digital Fault Recorder
Feeder and Main Application
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
Simple, accurate tenant sub-metering
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
PowerLogic® E5600 power and energy meter 1.
G650 Generator Protection & Control System
Looking for a more powerful circuit monitor?
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Need to enhance your network?
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
PowerLogic® PowerView Software
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
SmartMQn Motor Horner APG, LLC September 9, 2008.
PowerLogic PowerView v2.0 software
New product introduction:
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
VARLOGIC NRC12 Varmetric Controller
Avaya VA Line-interactive UPS
PMC-680i web interface Sep.9th 2016.
C1300 advanced circular chart recorder
IP-based 8-port Switched Power Manager
Maintain, Manage And Monitor Outdoor Systems Remotely
Reveal™ Touch Screen Product Overview
PowerValue 11 RT Sales Presentation
Flow-X/C Flow Computer
IP-AK2 Access Control Solution
NT24k® & 1000 PoE+ Offerings October 2016.
ICP DAS Power Monitor and Management Solution 2016,03,28
Introduction; iMCB a safety monitoring and energy management system, with smart disconnect features. It has a short circuit protection, leakage protection,
PowerValue 11/31 T Sales Presentation
Cover page.
PQube vs. X (instrument from competitors)
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
New features, more applications with PQube 3 Power Analyzers
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Moxa Embedded Solution on IEC 61850
Ethernet Gateway EGX200 - EGX400
Integrated gateway-server
PowerLogic™ offer for the basic metering market
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
Smart Prepayment Solutions for PV/SSEG
Revenue accuracy in a power quality meter
energy revenue & power quality meter
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Field installable, upgradeable and scaleable
Simple, accurate tenant sub-metering
PowerLogic ION Enterprise
Power monitoring software
Presentation transcript:

Compact, modular meters for feeders and critical loads PowerLogic PM800 series Compact, modular meters for feeders and critical loads

A PowerLogic system can help you… Improve energy efficiency and lower emissions Maximize the use of power distribution networks and reduce per-unit energy costs Improve overall power quality, reliability of equipment and processes

PowerLogic PM800 series meters Affordable, compact and modularly flexible meters designed for use on feeders and mains Install into new equipment or retrofit into existing installations Three models satisfy a range of applications

Part of a complete solution PM800 series meters can be used for standalone panel instrumentation, or as a key component in a complete power monitoring and control solution that provides transparent access to all of your intelligent devices. Data Communications - EGX100/EGX300 - Modems Intelligent Devices - All PowerLogic meters - Low voltage breakers - Med voltage relays - Other Modbus devices Software - PowerLogic ION Enterprise PowerLogic ION EEM PowerLogic PowerView Other compatible devices Energy and power quality meters and monitors Energy and power quality meters

Industries and applications Buildings Industry Energy & Infrastructure (includes utilities & critical power)

Industries and applications – Energy savings Key applications: Energy sub-billing Electricity procurement optimization Power factor correction Peak demand reduction Energy cost recovery Energy cost allocation (including bill auditing) Substation automation (industrial)

Industries and applications - Energy availability and reliability Key applications: Alarming and event logging Harmonic filtering Energy usage analysis Energy asset optimization (by building, floor, zone, PDU, or rack) Power quality monitoring & reporting

Industries and applications - Equipment optimization Balance loads plus reduce harmonics and other factors that cause heating and shorten equipment life Maximize existing capacity to avoid unnecessary capital purchases by understanding loading and identifying spare capacity on existing equipment

Summary of Key Features   PM810 PM810 with PM810Log PM820 PM850 PM870 Disturbance Detection n Advanced Waveform Capture EN50160 Evaluation Standard Waveform Capture Trending and Forecasting Custom Data Logging Size (kb) 80 800 Custom Logs 1 4 Billing Log Shift Energy Log Alarm Log Individual Harmonics 31st 63rd Accuracy ANSI 12.20 Class 0.2 and IEC 62053-22 Class 0.5S (all models) V, I, Energy, Demand, THD Alarms, RS485, Option Modules

Recent enhancements Real energy accuracy ANSI 12.20 Class 0.2 compliant IEC 62053-22 Class 0.5S compliant Remote display Type 12 compliant with Gasket. The new gasket ships with mounting kit included when you order any remote display models When the gasket is not installed, the PM8 remote display is Type 5 compliant Surge withstand compatibility IEEE C37.90.1:2002 compliant Surge immunity IEC 61000-4-12:2006 compliant PM850 and PM870 include 4 configurable datalogs GPS time synchronization. Available for any input (including built-in digital input S1) Power Quality Evaluation according to EN50160/ITI(CBEMA) and SEMI F47 power quality standards Input metering or WAGES support SNMP support with PM8ECC firmware version 2.2300

Part of a complete PowerLogic solution Integrate with PowerLogic ION Enterprise Helps engineering and management personnel meet operational goals: Improve efficiency and cut energy-related costs Assure reliability and reduce downtime Optimise equipment utilisation and reduce the cost of operations

Physical Features

Physical features Maintenance and alarm icons — view alarm status at the meter Easy-to-read, backlit LCD display Anti-glare, scratch resistant Displays four values simultaneously; view three phases and neutral View summary screens and bar chart displays to see a snapshot of your system Intuitive, self-guiding menus are easy to use without training Multiple languages — supports English, French, Spanish, German and other* The power meter’s three display options—integral display, no display, or remote display—let you purchase only what you need. * additional languages: Portuguese and Russian.

Physical features (continued) KY Out/Digital IN Control voltage Voltage Inputs — 600 VAC direct connect; eliminates the need for PTs in most cases Remote Display/Option Module connector Current inputs — rated at 15A, able to withstand overcurrents from CTs RS-485 communications, configurable for 2-wire Modbus-RTU or -ASCII Communicate to PowerLogic software Integrate into BAS or SCADA systems Download firmware updates to keep up-to-date with the latest features

Physical features (continued) Remote display option: Install the meter inside the low voltage cabinet when local regulations do not permit over 120 V on panel doors Can be used to configure meter when a permanent display is not required Provides an additional RS232/485 communications port, configurable for 2- or 4-wire support Type 2 compliant with gasket The configurable communications port on the remote display lets you add the power meter to an existing 4-wire RS-485 daisy-chain without a converter.

Physical features (continued) Compact design - 96 x 96 x 70mm (depth inside panel with Modbus and 2 I/O) Shallow depth saves panel space Flush panel mount with a 92 x 92mm cutout International standard design Retro-fit existing analog meters with 4” round cutouts — no mounting adapter required Din rail mounting w/o display Avoid voltage and current wires at panel door

PM800 series meter Add-on I/O modules

Field-installable input & output modules Flexible I/O Monitor equipment status Monitor and enunciate critical alarm status Sync with Utility demand intervals Monitor other utilities (water, gas, etc.) Standard I/O includes: 1 KY Digital output 1 Digital input Field-installable I/O option modules* Digital - 2 inputs and 2 outputs Digital - 6 inputs and 2 outputs Digital - 2 in and 2 out, Analog - 2 in and 2 out Two I/O modules can be installed on the back of the power meter.

PM8ECC PM800 series Ethernet communications module

PM8ECC Power Status LED indicators for Ethernet communications Bias, Termination, & 2-wire / 4-wire jumper switches LED indicators for serial communications 10/100Base Tx RS485 serial port

Features Provides direct Ethernet connectivity solution using an existing LAN/WAN network Offers a high-speed communication connection to increase system performance on alarms and data transfers Allows a wider range of connectivity options E-mail on alarm notification Field installable - no external power supply requirement Field downloadable firmware for easy upgrades Industrial operating temperature range (-25 to 70oC) Fully isolated communication ports TRE1 (Transparent Ready Power Equipment – Level 1) compliant Advanced security (session based log-on, ModbusTCP filtering) Configurable bias and termination for the RS485 serial port Web browser based Diagnostics and Register Reader SNMP support for a private host PM8ECC MIB allowing the reading of Basic Metering Data, I/O Configuration and Status, Alarm Configuration and Status, plus SNMP Trap generation in response to any PM8 on-board alarm.

Technical specifications 10/100BaseTx Ethernet Supported protocols: ModbusTCP/IP, FTP, SNMP MIB2, ARP, UDP, and HTTP, SMTP, SNTP LED indicators: Link, Tx, Rx, Link speed (10/100 differentiated by color) RS485 serial port Baud rates from 2400 to 38.4k Full optical Isolation Serial protocols include: Modbus/RTU, , PowerLogic and Jbus Screw terminal connector for RS485 Support for 2-wire and 4-wire daisy-chains Configurable bias and termination LED indicators: Tx, Rx

SNMP support Simple Network Management Protocol (SNMP) is a UDP-based network protocol. It is used mostly in network management systems to monitor  network-attached devices for conditions that warrant administrative attention SNMP is typically supported in datacenters and systems that use Uninterruptible Power Supply (UPS). SNMP is the choice protocol for these system. As a result, the administrator of these facilities require information represented in this format. SNMP support for the PM8ECC (with firmware version 2.300 or above) includes Traps. Traps are notifications sent from the SNMP Agent to the SNMP Manager. We use Traps within the SNMP protocol to send PM8 Alarm notifications.

Installation

Designed with the panel builder in mind Single person installation Mounting resistance nibs hold meter until the mounting clips are snapped into place No tools required to mount the meter Direct connection of Voltage Inputs Up to 600 Vac Wide range control power supply 115 – 415 Vac (15 vA); 125 – 250 Vdc (10 watts) Reduces the number of models to order and stock

Real energy accuracy

Power and accuracy One of the most powerful microprocessors in its class 128 Samples/Cycle provides high accuracy and harmonic data Zero blind metering — no blind spots in data Meets ANSI C12.20 Class 0.2 and IEC 62053-22 Class 0.5S for Active Energy (all models)

Advanced features

Customizable alarming Factory configured alarms Detect circuit overloading before the breaker trips Quickly identify the source of a problem Create custom alarms (PM820, PM850, PM870) Combine up to four alarms using Boolean logic (PM850 and PM870) Voltage/current disturbance alarms for sag/swell detection (PM870) The power meter’s alarm summary can help identify persistent alarm conditions that need attention. Alarms, stored in power meter memory and viewed in PowerLogic software, provide early warning of potential problems.

Advanced logging Onboard memory for reliable collection of historical data: PM850, PM870 - 800k standard PM810 with logging module, PM820 - 80k standard Factory default logging starts as soon as meter is powered up Benefits of onboard data logging: Reduce network traffic Prevent gaps in data due to network or computer downtime Logged data can be downloaded to PowerLogic software for use in historical reports for capacity planning, energy trending, and more.

Advanced logging (continued) On board data logs include: Min/Max log—min/max value for each quantity since last reset Custom data logs with up to 96 quantities each (One log – PM820 and PM810 with logging module; Three logs – PM850, PM870) Billing log and Shift Energy table The power meter’s billing log can be uploaded and viewed in PowerLogic System Manager software. Quantities Logged Minutes Days Months kWh IN kWh OUT kVARh IN kVARh Out kVAh Total PF Total kW Demand kVAR Demand Each 15 Min for 12 days (1152 intervals) 32 Days of Daily logs (32 intervals) 52 days of storage for a single register quantity 48 days of a single energy value (4 registers) 2 years of monthly logs (24 Intervals) Notes Quantities logged are default values and are user-definable. Daily and monthly PF and demand values represent the last value of the day or month.

Advanced logging (continued) Shift energy log tracks energy usage and cost for up to three, user-definable shifts Register-based data is accessible by building automation and SCADA software

Power quality monitoring Current and voltage individual harmonic magnitudes and angles to the 31st harmonic (PM810LOG, PM820), or 63rd harmonic (PM850, PM870) Total harmonic resolution to the 63rd harmonic for RMS values

Power quality monitoring (continued) The power meter (PM850, PM870) measures power quality according to the EN50160/ITI(CBEMA) and SEMI F47 Power Quality standards. The EN50160 standard defines the voltage quality a customer can expect from the utility. The status (pass or fail) of each evaluation category can be viewed in ION- E tables. The power meter generates alarms when an area of evaluation is outside of the range of acceptable values.

Standard waveform capture (PM850) Manual or Alarm initiation 128 samples/cycle, 3 cycles Waveforms give a graphical representation of what’s happening with your power during a particular moment. Quickly isolate potential power problems. Excellent for troubleshooting problems that occur continuously.

Disturbance detection and advanced waveform capture (PM870) The PM870 has the ability to detect, alarm upon, and capture voltage and current sags and swells that can cause unwanted trips and process interruptions, damage motors and more. Twelve factory configured voltage disturbance (sag/swell) alarms provide warning and trigger a disturbance waveform capture. Disturbance alarms can be reconfigured for current sag and current swell using PowerLogic software. Voltage sags are often caused by heavy loads being started. The PM870’s disturbance detection features can help isolate the source of troublesome sags and swells.

Disturbance detection and advanced waveform capture (continued) Advanced waveform capture (PM870) provides a detailed picture of the disturbance event Configurable from 185 cycles on one channel at 16 samples/cycle up to 3 cycles on six channels at 128 samples/cycle Poor power quality can lead to costly downtime. A PM870’s disturbance waveform capture can provide the information needed to diagnose an event.

Trending and forecasting (PM850, PM870) The power meter maintains onboard trends with historical values and forecast values to help predict future performance Min/Max and Average data available for minutes, hours, days and months Forecast for hours and days Hourly and weekly summaries Trend tables for typical values (e.g. Real Power, Current, Voltage) can be viewed in PowerLogic software Since trend data is register-based, it is accessible by building automation and SCADA software The power meter’s onboard trend data with predicted values, can be viewed in PowerLogic software.

For more detailed information on this product, or other products, services and solutions Ask your Schneider Electric representative Visit www.schneider-electric.com/