Transluminal placement of a prosthetic graft-stent device for treatment of subclavian artery aneurysm  James May, MS, FRACS, FACS, Geoffrey White, FRACS,

Slides:



Advertisements
Similar presentations
Platelet survival and serotonin content after placement of arterial prostheses in dogs: Effects of neointimal coverage and high- and low-dose aspirin G.Patrick.
Advertisements

Popliteal artery stenosis caused by a Baker's cyst
Christopher A. DeMaioribus, MD, Charles A. Anderson, MD, Sandy S. G
Endoluminal repair of atypical dissecting aneurysm of descending thoracic aorta and fusiform aneurysm of the abdominal aorta  James May, MS, FRACS, Geoffrey.
Axillary-to-carotid artery bypass grafting for symptomatic severe common carotid artery occlusive disease  Joseph P. Archie, PhD, MD  Journal of Vascular.
Modular component separation and reperfusion of abdominal aortic aneurysm sac after endovascular repair of the abdominal aortic aneurysm: A case report 
R. Huilgol, H. Verhagen, J.P. Harris, G.H. White 
Follow-up of renal artery stenosis by duplex ultrasound
Diagnosis and treatment of thoracic aortic intramural hematoma
Arterial rupture without balloon rupture during percutaneous transluminal angioplasty  Timothy P. Murphy, M.D., John J. Cronan, M.D., Landy P. Paolella,
Fetal internal iliac artery: Case report and embryologic review
Endovascular grafts for noninfected aortoiliac anastomotic aneurysms
J. Parfitt, MB, BS, R.T.A. Chalmers, MD, FRCS, J.H.N. Wolfe, MS, FRCS 
Louis L. Smith, M. D. , Douglas C. Smith, M. D. , J. David Killeen, M
Infected renal artery pseudoaneurysm and mycotic aortic aneurysm after percutaneous transluminal renal artery angioplasty and stent placement in a patient.
Mycotic axillary artery aneurysm
A new valvulotome for in situ bypass grafts
Treatment of complex abdominal aortic aneurysms by a combination of endoluminal and extraluminal aortofemoral grafts  James May, MS, FRACS, FACS, Geoffrey.
Michael L. Marin, MD, Frank J. Veith, MD, Thomas F
Jeffrey R. Rubin, M.D., James M. Malone, M.D., Jerry Goldstone, M.D. 
James May, MS, FRACS, FACS, Geoffrey H
Aneurysm of aberrant subclavian artery with a review of the literature
Intra-arterial streptokinase therapy to relieve acute limb ischemia
Malcolm O. Perry, MD, Richard Kempczinski, MD 
Michael J. Petersen, MD, Richard P. Cambria, MD, John A
Catheter-induced bilateral internal carotid artery occlusion
Ruptured ovarian artery aneurysm: A case report
Popliteal artery entrapment: An evolving syndrome
Hybrid management of proximal right subclavian artery aneurysms
Juan Carlos Parodi, MD  Journal of Vascular Surgery 
Follow-up of renal artery stenosis by duplex ultrasound
Endovascular treatment of ruptured axillary and large internal mammary artery aneurysms in a patient with Marfan syndrome  Jessica F. Rose, DO, Layla.
Presidential address: Vascular surgery—The third generation
Aneurysms of the mid axillary artery in major league baseball pitchers—A report of two cases  George J. Todd, MD, Alan I. Benvenisty, MD, Stuart Hershon,
Richard E. Parsons, MD, Michael L. Marin, MD, Frank J
Intraoperative arteriography and carotid surgery
Duplex–assisted internal carotid artery balloon angioplasty and stent placement: A novel approach to minimize or eliminate the use of contrast material 
Gorav Ailawadi, MD, Asheesh Bedi, BS, David M. Williams, MD, James C
Harry Spoelstra, MD, Filip Casselman, MD, Olivier Lesceu, MD 
Vein compression by arterial aneurysms
Proximal bleeding control obtained by a balloon catheter in the surgical repair of a left supraclavicular traumatic arteriovenous fistula  A. Nemes, L.
James R. Burnett, MB, BS, FRACS, Robert J. Lusby, MD, FRCS, FRACS 
J. Parfitt, MB, BS, R.T.A. Chalmers, MD, FRCS, J.H.N. Wolfe, MS, FRCS 
Aortoiliac surgery in renal transplant patients
Ann L. Peick, MD. , W. Kirt Nichols, MD, Jack J
Comparison of first- and second-generation prostheses for endoluminal repair of abdominal aortic aneurysms: A 6-year study with life table analysis  James.
Platelet survival and serotonin content after placement of arterial prostheses in dogs: Effects of neointimal coverage and high- and low-dose aspirin 
Composite sequential bypasses to the ankle and beyond for limb salvage
Dipankar Mukherjee, M. D. , William J. Schickler, M. D
James E. Edwards, MD, Lloyd M. Taylor, MD, John M. Porter, MD 
Seizures following subclavian-carotid bypass
Carotid biaxillary bypass: A new operation
Traumatic false aneurysm of the common carotid artery presenting as a mediastinal mass: A case report  Lewis B. Schwartz, MD, Richard L. McCann, MD  Journal.
Kim J. Hodgson, M.D., David S. Sumner, M.D. 
The effects of endothelial injury on smooth muscle cell proliferation
Monitoring vascular surgical performance
William E. Evans, M.D., James P. Hayes, M.S. 
Recognition and treatment of arterial insufficiency from Cafergot
Superficial temporal artery aneurysms
George D. Lilly 1906–1988 Journal of Vascular Surgery
Intramural dissection of superior mesenteric artery
Chronic intraaneurysmal pressure measurement: An experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion  Luis.
James A. DeWeese, MD  Journal of Vascular Surgery 
Left subclavian artery aneurysm: Two cases of rare congenital etiology
Transfemoral endovascular aortic graft placement
Axillary-to-carotid artery bypass grafting for symptomatic severe common carotid artery occlusive disease  Joseph P. Archie, PhD, MD  Journal of Vascular.
Early outcome and intermediate follow-up of vascular stents in the femoral and popliteal arteries without long-term anticoagulation  Geoffrey H. White,
Endovascular repair of two abdominal aortic aneurysms
Optimal proximal anastomosis/tunnel for axillofemoral grafts
Richard L. McCann, MD, R.Randal Bollinger, MD, Glenn E. Newman, MD 
Presentation transcript:

Transluminal placement of a prosthetic graft-stent device for treatment of subclavian artery aneurysm  James May, MS, FRACS, FACS, Geoffrey White, FRACS, Richard Waugh, MB, BS, DDR, FRACR, Weiyun Yu, MB, BS, John Harris, MS, FRACS, FACS  Journal of Vascular Surgery  Volume 18, Issue 6, Pages 1056-1059 (December 1993) DOI: 10.1016/0741-5214(93)90562-Z Copyright © 1993 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 1 Preoperative arteriogram showing false aneurysm of right subclavian artery. Note relatively normal subclavian and axillary arteries distal to aneurysm. Journal of Vascular Surgery 1993 18, 1056-1059DOI: (10.1016/0741-5214(93)90562-Z) Copyright © 1993 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 2 Graft-stent device is shown mounted on balloon catheter in lower half of figure. Proximal one quarter of stent can be seen projecting beyond graft (arrow). Remainder of stent is covered by furled graft. 16 F sheath and dilator are shown above. Journal of Vascular Surgery 1993 18, 1056-1059DOI: (10.1016/0741-5214(93)90562-Z) Copyright © 1993 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 3 Completion arteriogram showing normal flow through subclavian artery without leakage of contrast into aneurysm sac. Proximal and distal ends of graft-stent device are indicated by arrows. Heavy metallic markings of radiopaque ruler are also seen. Journal of Vascular Surgery 1993 18, 1056-1059DOI: (10.1016/0741-5214(93)90562-Z) Copyright © 1993 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions