Serum S100β release after coronary artery bypass grafting: roller versus centrifugal pump Saeed Ashraf, Kausik Bhattacharya, Sunny Zacharias, Pradeep Kaul, Philip H Kay, DM, Kevin G Watterson The Annals of Thoracic Surgery Volume 66, Issue 6, Pages 1958-1962 (December 1998) DOI: 10.1016/S0003-4975(98)00904-7
Fig 1 An error bar graph showing the serum S100β profiles in both groups. The boxes represent the mean value, with the whiskers showing the 95% confidence interval. (CPB = cardiopulmonary bypass; Preop = preoperative value). The Annals of Thoracic Surgery 1998 66, 1958-1962DOI: (10.1016/S0003-4975(98)00904-7)
Fig 2 Scatterplot showing the relation between peak S100β levels and cross-clamp time in the centrifugal pump group (r = 0.66, p = 0.008). The Annals of Thoracic Surgery 1998 66, 1958-1962DOI: (10.1016/S0003-4975(98)00904-7)
Fig 3 Scatterplot showing the relation between 30-minute S100β levels (r = 0.62, p = 0.001), and 24-hour S100β levels (r = 0.32, p = 0.10) in all patients. The Annals of Thoracic Surgery 1998 66, 1958-1962DOI: (10.1016/S0003-4975(98)00904-7)