ODS AND ALTERNATIVES IN RAC SECTOR

Slides:



Advertisements
Similar presentations
1 HCFC Phase –out in Air Conditioning Sector Background, Challenges and Progress Sidi Menad SI AHMED 17 TH October 2012.
Advertisements

M o n t r e a l P r o t o c o l, O E W G - 3 0, G e n e v a, J u n e XIX/8 Report on HCFC Alternatives for High Ambient Temperature.
GreenChill & Natural Refrigerants
Refrigeration & Air Conditioning
REFRIGERATION SYSTEMS
Refrigeration Cycles CHAPTER 11: PTT 201/4 THERMODYNAMICS
REFRIGERATION Refrigeration may be defined as the process of removing heat from a substance under controlled conditions and reducing and maintaining the.
Michael Galka and Dr. Paul Blowers The University of Arizona
Refrigeration and Heat Pump Systems
Session I Challenges and opportunities in addressing high-GWP HFCs in the refrigeration sector.
New Refrigerants Question Time Introductory Comments Ray Gluckman Director, Climate Change SKM Enviros April 26 th 2012, RAC, London.
System and Component Efficiency with Refrigerant R410a A. T. Setiawan 1, A. Olsson 2, H. Hager 2 1 Department of Energy Technology, Div. Of Applied Thermodynamics.
REFRIGERATION & AIR CONDITIONING DIVISION Hydrocarbons for Domestic Appliances Dr.-Ing. Jürgen Süss VP R&D Brussels, October 2009.
Creating the right business climate for innovation – A CO2 success story Bruxelles OCT 2009 Torben M Hansen.
UNEP Workshop on HFCs management.
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
Technical consideration of feasibility of low GWP alternatives: performance, cost, et.al. Kazuhiro Sato Mitsubishi Heavy Industries, Ltd. On behalf of.
H F C M a n a g e m e n t W o r k s h o p, J u l y , P a r i sRoberto Peixoto - IMT Roberto A. Peixoto Maua Institute of Technology - IMT.
Low-GWP options for cascade systems for medium-sized and larger commercial refrigeration equipment Workshop on HFC management Bangkok 20 th April 2015.
Département fédéral de l'environnement, des transports, de l'énergie et de la communication DETEC Office fédéral de l'environnement OFEV Swiss policies.
UNEP Ozone Secretariat Workshop on HFC management: technical issues Overview of HFC Market Sectors Presentation by Lambert Kuijpers, Ray Gluckman and Sukumar.
EGR 334 Thermodynamics Chapter 10:
Refrigeration Cycles Chapter 11: ERT 206/4 THERMODYNAMICS
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
DAIKIN February 18 th, 2011 Daikin US How to Evaluate Refrigerants? >Global Warming Impact >Energy efficiency & Peak Load >Flammability & Toxicity >Affordability.
Solar cooling systems.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
Session 5 Overarching and cross-cutting issues on technical aspects of HFC management.
HFO Low Global Warming Technology Rene Mueller. Honeywell.com  2 Honeywell initiated R&D on low global warming programs in 2001 Programs in place for.
36th OEWG UNEP SIDE EVENT 22 J u l y , P a r i sRoberto Peixoto - IMT Roberto A. Peixoto Maua Institute of Technology – IMT Brazil Disclaimer: The.
Availability of Low-GWP Alternatives Options for Near Term & Longer Term Transitions OZONACTION NETWORK FOR LATIN AMERICA AND THE CARIBBEAN OCTOBER 6-8.
The new EU F-Gas Rules and their impact in Europe and globally By Andrea Voigt, EPEE Workshop on Hydrofluorocarbon Management Bangkok – 20 & 21 April 2015.
Objectives Solve examples Learn about refrigerants, compressors, and expansion valves (Ch. 4) Compare residential and commercial systems Introduce heat.
WEL COME TO COE RAC SECTOR ITI UTTARSANDA. ADVANCE MODULE :-I Advance Module in Domestic, Commercial Refrigeration and Air Conditioning.
In the 1970’s, scientists discovered the dangerous impact that CFC’s have in the Earth’s atmosphere. They were destroying the ozone layer which protects.
REFRIGERATION SYSTEMS
INDUSTRY PROGRESS AND NEEDS FOR REPLACING HIGH GWP HFC S Montreal Protocol HFC Management Workshop Paris July 11, 2014.
00 Heat pumps by Kenneth Hoffmann. Why NH 3 Heat pump? NH 3 Heat Pump sizes Case stories CO 2 Heat Pump NH 3 Heat Pump applications NH 3 Heat Pump sizes.
PRIMARY AND SECONDARY REFRIGERANTS
Basic Refrigeration. Star Refrigeration Wednesday 12 September 2007.
PHYSICAL, CHEMICAL AND THERMODYNAMIC PROPERTIES OF REFRIGERANTS REFRIGERANT: It is any substance that absorb heat through expansion or vaporization and.
Prepared by:- B.S.Bhandari Faculty HNBGU.  Refrigeration is a science of producing and maintaining temperature below that of the surrounding temperature.
Opportunities to Leapfrog High-GWP HFCs when Phasing out HCFCs
Importance of NIK Alternatives to Phase Down of High GWP HFCs Steve Seidel and Jason Ye (C2ES), Stephen O. Andersen (IGSD), and Alex Hillbrand (NRDC) 28.
Refrigeration.
SAI BHARATH SRAVAN KUMAR
. Level 3 Air Conditioning Inspections for Buildings
Refrigeration & air conditioning
.. Level 3 Air Conditioning Inspections for Buildings
Refrigeration and Heat Pump Systems
HYDRONIC HVAC: The Most Comfortable and Efficient System
Introduction to Food Engineering
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Commercial Refrigeration Trends and challenges for RECS
HYDRONIC HVAC: The Most Comfortable and Efficient System
Lecture Objectives: Continue with Sorption Cooling
High Temperature Reservoir Low Temperature Reservoir
THIRD ANNUAL CO3OL WORKSHOP
Maniks Desuperheater a High Performance Energy Saving Product
FGas Regulation Revision : Industry Impact
Chapter 14C: REFRIGERANTS
High Efficiency Room Air-conditioners
Hydrocarbon Refrigerants
Presentation by Ray Gluckman July 9th 2018, Vienna
Radhey S. Agarwal Member, OORG
Refrigeration & Air conditioning
Low-GWP blowing agents as alternatives of HCFC-141b
Overview of Technical and Policy Challenges in meeting 2020 phase-out targets Annual 2017 Network Meeting of National Ozone officers of South Asia Countries.
CHALLENGES IN MEETING 2020 HCFC PHASE OUT TARGETS
Presentation transcript:

ODS AND ALTERNATIVES IN RAC SECTOR Training of New NOOs Agra, India, 23 -26 May 2017

THE REFRIGERATION CYCLE

WHAT IS REFRIGERANT IN RAC A chemical substance that absorbs heat from low- pressure, low temperature evaporator and condenses at a higher pressure, high temperature condenser In the process of absorbing and condensing heat refrigerant will change state from liquid to vapour and back The choice of refrigerant depends on design and purpose of RAC units

REFRIGERANTS IN RAC SECTOR ODP GWP R-22 0.055 1,820 R-123 0.02 93 R-134A 1,300 R-407A 1,770 R-407C 1,530 R-410A 2,090

CRITERIA FOR ALTERNATIVES SELECTION

ALTERNATIVES TO ODS IN RAC HFCs with low GWP – pure or in mixtures Natural refrigerants Unsaturated HFCs

LOW GWP HFCs: R-32 R-32 – difluoromethane - CH2F2 Either alone or as component of refrigerant blends (e.g. R-410C or R-407A) in industrial refrigeration Efficiently conveys heat and thus can reduce electricity consumption up to 10% (compared to RAC equipment with R-22) Global warming potential (GWP) one-third lower and is thus remarkable for its low environmental impact Has a high discharge temperature that can lead to oil degradation which can cause compressor failure

LOW GWP HFCs : R-32

ADVANTAGES OF R-32 R-410A is the refrigerant most commonly used in developed countries R-32 has a similar pressure as R410A - this can ease the development on an R-32 system based on an R-410A platform R-32 has a higher critical temperature which yields a higher COP of RAC equipment If all R-410A were converted to R-32, the impact to global warming from HFCs in 2030 would be reduced by the CO2equivalent of approximately 800 million tons (19%) compared to the continued use of R-410A

LOW GWP HFCs: R-152 R-152A – 1,1-Difluoroethane - CH3CHF2 Blend component of several refrigerant blends; potential application in mobile air conditioning R152a is suitable for use in new equipment Also used as the working fluid of temperature controllers Besides RAC also can be used as blowing agent (XPS foams), cleaning agent and aerosol Its flammability creates challenges thus limiting its use

LOW GWP HFCs: R-161 R-161 – Fluoroethane - C2H5F Better COP, increased refrigeration effects and lower discharge temperatures Power consumed found to be greater than other refrigerants hence issues of energy efficiency In general has good performance characteristics but official safety classification is not yet established Problems are flammability as well as thermal stability at high ambient temperatures

HFC BLENDS – R-407C R-407C = mixture of (HFC-32/125/134a) Retrofit candidate with HFCs; Lower energy efficiency and capacity Lubricant change needed Material compatibility issues Was used in developed countries for early phase out of HCFC-22 but is decreasing

HFC BLENDS – R-410A R-410A = mixture of HFC-32 and HFC-125 Suitable for new systems Significant design changes needed (e.g. new compressor, lubricant, capillary tube etc.) Operates at higher pressures than other refrigerants thus R-410A systems require to use different tools, equipment, safety standards and techniques Preferred for use in residential and commercial air conditioners in Japan, Europe and the United States Only HFC blend extensively used in many countries

OTHER HFC BLENDS R-417A (HFC-125/ HFC-134a/ HC-600): Retrofit candidate with HFCs; similar capacity but material compatibility issues; Not seriously considered in developed countries; R-422A (HFC-123/HFC-134a/ HC-600a): Retrofit candidate with HFCs; Material compatibility issues; Drop in capacity; Not seriously considered in developed countries R-433A (HC-290/HC-1270): Retrofit candidate; Drop in capacity, about 5% and 5-8% more energy efficiency than HCFC-22; Not seriously considered in developed countries due to safety issues

HFC BLENDS – PROS AND CONS Non-flammable Useable heat capacity close to HCFC 22 (e.g. R-407C) COP less than HCFC Reliability/Compatibility issues with the materials of system construction System changes necessary

ALTERNATIVES TO ODS IN RAC HFCs with low GWP – pure or in mixtures Natural refrigerants Unsaturated HFCs

NATURAL REFRIGERANTS - HYDROCARBONS R- 290 – propane; R–600a - isobutane , R-1270 -propylene R-290 suitable for residential and non- residential AC as well as commercial and industrial refrigeration applications (medium and low temp.) R-600a widely-used for household refrigerators (lower working pressure compared to other HCs R-1270 suitable for medium- and low-temperature commercial and industrial refrigeration as well as low temperature water-glycol chilling units for industrial applications

NATURAL REFRIGERANTS - HYDROCARBONS Good compatibility with materials (mineral oil lubricants) Well suited for high ambient temperatures Price is lower than that of other synthetic refrigerants Use for cooling/heating more efficient than with synthetic refrigerants Flammability requires special care in design, manufacturing and service Centralized systems have substantially higher ICC and increased energy demand

NATURAL REFRIGERANTS - HYDROCARBONS Knowledge of legislation, regulations and standards relating to flammable refrigerants Electrical devices attached to / close to system must be non-sparking (sealed type) or solid state or installed in separate/ adjacent room Provision of adequate ventilation surrounding system/equipment HC charge is lower by more than 50% of HCFC by weight Safe manufacturing / servicing for refrigerant leakage prevention, handling of cylinders, charging, leak detection etc.

NATURAL REFRIGERANTS - CO2 R- 744 – CO2 - carbon dioxide` Excellent thermodynamic properties make it suitable for a range of applications e.g. often the choice for the low temperature stage in commercial and industrial cascade refrigeration systems Energy efficiency better than HFC systems below 24 C ambient Lower material cost- allowing systems with small volumes Stronger materials required (working pressures above 75 bar at ambient temperatures) Loss of performance of the systems in high ambient climates Special material and construction demands thus not suitable for retrofit

NATURAL REFRIGERANTS - NH3 R-717 – Ammonia – NH3 Highest refrigerating capacity per pound of any refrigerant Less expensive than HFCs Lower material cost- because of narrower diameter piping in ammonia-based refrigeration systems Energy efficient - requires less electricity, resulting in lower operating costs than HFC systems Corrosive to copper and brass (not to steel and aluminium) Poisonous in high concentrations (but detectable at concentrations well below dangerous)

NATURAL REFRIGERANTS - NH3 Standard refrigerant for industrial refrigeration systems for more than 125 years Ammonia refrigeration systems for low temperature applications must be designed in two stages with intermediate cooling Used with indirect systems in public access areas (systems with evaporating secondary refrigerant for the medium temperature and/or low temperature range) Recently used as the higher temperature stage in CO2 cascade refrigeration systems

ALTERNATIVES TO ODS IN RAC HFCs with low GWP – pure or in mixtures Natural refrigerants Unsaturated HFCs

UNSATURATED HFCs - HFOs R-1234yf (DuPont and Honeywell) - a successor to R134a for mobile air-conditioning Similar thermal properties to R134a, meaning there are only minor system layout and design differences; potential application in chillers R-1234ze (Honeywell’s Solstice® ze) - alternative to traditional refrigerants for energy-efficient chillers and/or commercial air conditioning in supermarkets and commercial buildings Also suitable for other medium-temperature applications e.g. heat pumps, refrigerators, vending machines beverage dispensers

UNSATURATED HFCs - HFOs Very low GWP (<1) due to higher reactivity and thus shorter lifetimes in troposphere Processes and by-products in the manufacture not well known (potentially HFC-23) Health impact unclear due to variable toxicology Flammability not well known Problems of commercial availability and relatively high price

BARRIERS TO USE OF LOW-GWP ODS ALTERNATIVES Technical design and safety design (additional cost) Supply and availability (materials, equipment, components) Commercial (investment, profit, financial incentives) Market (customer, competing products) Information resources (know-how, guidance, technical data) Regulatory and quasi-regulatory (legislation, standards) Psychological and sociological aspects

PROMOTION OF LOW-GWP ODS ALTERNATIVES Use of low GWP alternatives driven primarily by commercial criteria (price, ICC, IOC, commercial availability of refrigerants) Political decisions important factor for promotion of long term solutions (e.g. Kigali Amendment of MP) Financial incentives trigger move to long term alternatives - e,g MP grants Demonstration projects for specific alternative refrigerants entering the market (e.g. HFOs)

THANK YOUFOR YOUR ATTENTION!