Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module by Hyunjae Lee, Changyeong Song, Yong Seok Hong,

Slides:



Advertisements
Similar presentations
Date of download: 9/19/2016 Copyright © 2016 SPIE. All rights reserved. Fabrication of hydrophilic poly-ethylene terephthalate (PET) film chip for whole.
Advertisements

Near-infrared light-responsive nanoparticles with thermosensitive yolk-shell structure for multimodal imaging and chemo-photothermal therapy of tumor 
by Huichan Zhao, Kevin O’Brien, Shuo Li, and Robert F. Shepherd
Volume 99, Issue 4, Pages (August 2010)
Volume 1, Issue 1, Pages (September 2017)
Wei-Ran Huang, Zhen He, Jin-Long Wang, Jian-Wei Liu, Shu-Hong Yu 
Selection and Identification of Skeletal-Muscle-Targeted RNA Aptamers
Volume 3, Issue 6, Pages (December 2017)
Volume 25, Issue 7, Pages (July 2017)
Blocking Ca2+ Channel β3 Subunit Reverses Diabetes
Characterization of the light-responsive transdermal MNs.
Fig. 1 Digital microfluidic cartridge and ELISA used for measles and rubella testing. Digital microfluidic cartridge and ELISA used for measles and rubella.
Fig. 4 3D reconfiguration of liquid metals for electronics.
Fig. 2 Electronically conducting xylem wires.
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. Fluidic and electrical characteristics of the wireless optofluidic system.
Fig. 4 Kinetics of dissolution and histological studies of bioresorbable optical sensors and fibers. Kinetics of dissolution and histological studies of.
Vaccine MN confer protective innate and adaptive immunity.
Fig. 5 Analytical performance of the wearable cortisol sensor.
Fig. 3 Piezoresistive e-skin with interlocked microdome arrays for simultaneous detection of static pressure and temperature. Piezoresistive e-skin with.
Fig. 1 TED design and fabrication process.
Fig. 2 Materials and designs for bioresorbable PC microcavity-based pressure and temperature sensors. Materials and designs for bioresorbable PC microcavity-based.
Mechano-thermo-chromic device with supersaturated salt hydrate crystal phase change by Hyunmin Cho, Jinhyeong Kwon, Inho Ha, Jinwook Jung, Yoonsoo Rho,
Fig. 3 Power generation of the TED and its impact on active cooling.
A microrobotic system guided by photoacoustic computed tomography for targeted navigation in intestines in vivo by Zhiguang Wu, Lei Li, Yiran Yang, Peng.
Fig. 5 Wearable closed-loop HMI.
Fig. 3 Characteristics of UV and temperature sensors.
Fig. 2 Implantation procedure for the NET probes.
Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat by Amay.
by Jinqiang Wang, Jicheng Yu, Yuqi Zhang, Xudong Zhang, Anna R
Ultraflexible organic photonic skin
Hygrobot: A self-locomotive ratcheted actuator powered by environmental humidity by Beomjune Shin, Jonghyun Ha, Minhee Lee, Keunhwan Park, Gee Ho Park,
Fig. 4 Real-time optical and thermal response during the reversible phase transition. Real-time optical and thermal response during the reversible phase.
The prototype and working mechanism.
Fig. 1 Operation mechanism and scanning electron microscopy images of MTC device. Operation mechanism and scanning electron microscopy images of MTC device.
Fig. 1. Overview of the dongle.
Fig. 1 Characterization of particles and scaffold.
Gemcitabine-Incorporated G-Quadruplex Aptamer for Targeted Drug Delivery into Pancreas Cancer  Jun Young Park, Ye Lim Cho, Ju Ri Chae, Sung Hwan Moon,
Near-infrared light–responsive dynamic wrinkle patterns
Nanoscale magnetic imaging of ferritins in a single cell
Fig. 1 Synthesis and characterization of Dox-CBD-SA.
Illustration of MIS-C and the characterization of the device structure
Fig. 2 Large-area and high-density assembly of AuNPs.
Fig. 1 In vitro calibration plots and pH maps using iopamidol in human blood serum. In vitro calibration plots and pH maps using iopamidol in human blood.
A dual-mode textile for human body radiative heating and cooling
by Ryan M. Williams, Christopher Lee, Thomas V. Galassi, Jackson D
Selective targeting of primary and secondary nucleation pathways in Aβ42 aggregation using a rational antibody scanning method by Francesco A. Aprile,
Fig. 1 Schematics of R2R fabricated sweat sensing patches for regional and correlative sweat analysis. Schematics of R2R fabricated sweat sensing patches.
Fig. 1 Schematic view and characterizations of FGT/Pt bilayer.
by Yan Feng, Hui Liu, and Jun Yang
Fig. 3 The bacteria loading capacity and biocompatibility of GA/Pt.
Fragmented SHE design of e-skins for fine conformability.
Dipole-like electrostatic asymmetry of gold nanorods
Fig. 3 Characterization of PCNs and PCN-loaded microneedles.
Fig. 2 Optimization of the sweat control and characterization of individual sensors. Optimization of the sweat control and characterization of individual.
Fig. 1 Synthesis and characterization of PE-E/Pt.
Fig. 5 Piezoelectric e-skin with interlocked microdome array for dynamic touch and acoustic sound detection. Piezoelectric e-skin with interlocked microdome.
Fig. 4 Sweat-based glucose monitoring and feedback therapy in vivo.
Enhanced PEDOT adhesion on solid substrates with electrografted P(EDOT-NH2)‏ by Liangqi Ouyang, Bin Wei, Chin-chen Kuo, Sheevangi Pathak, Brendan Farrell,
Multiplexed four- and eight-channel devices for rapid processing
Fig. 5 Simulation of the mechanical properties of the 3DGraphene foam in a wide temperature range down to the cryogenic region. Simulation of the mechanical.
Fig. 4 In vivo evaluation of insulin complex for type 1 diabetic mice treatment. In vivo evaluation of insulin complex for type 1 diabetic mice treatment.
Fig. 2 Temperature-sensing properties of the flexible rGO/PVDF nanocomposite film. Temperature-sensing properties of the flexible rGO/PVDF nanocomposite.
Fig. 1 Ultrathin, stretchable, mechanically imperceptible, multifunctional HMI device for human and robotics. Ultrathin, stretchable, mechanically imperceptible,
Fig. 2 Physical properties and measured responses of the sensors.
SEM and TEM images and photoluminescence properties of composites
Dissociation of Aβ aggregates and detection of Aβ on IME sensor
Fig. 3 Rubbery strain, pressure, and temperature sensors.
Fig. 4 “Editing”—Write-erase-rewrite using PLE.
Fig. 3 Correction of Dmd exon 44 deletion in mice by intramuscular AAV9 delivery of gene editing components. Correction of Dmd exon 44 deletion in mice.
by Sanha Kim, Yijie Jiang, Kiera L. Thompson Towell, Michael S. H
Presentation transcript:

Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module by Hyunjae Lee, Changyeong Song, Yong Seok Hong, Min Sung Kim, Hye Rim Cho, Taegyu Kang, Kwangsoo Shin, Seung Hong Choi, Taeghwan Hyeon, and Dae-Hyeong Kim Science Volume 3(3):e1601314 March 8, 2017 Copyright © 2017, The Authors

Fig. 1 Wearable/disposable sweat monitoring device and microneedle-based transdermal drug delivery module. Wearable/disposable sweat monitoring device and microneedle-based transdermal drug delivery module. (A) Optical camera image (top; dotted line, edges of the patch) and schematic (bottom) of the wearable sweat monitoring patch. A porous sweat-uptake layer is placed on a Nafion layer and sensors. (B) Optical camera image (top) and schematic (bottom) of the disposable sweat monitoring strip. (C) Optical camera image (top; dotted line, edges of the patch) and schematic (bottom) of the transdermal drug delivery device. Replacement-type microneedles are assembled on a three-channel thermal actuator. (D) Schematic drawing of the glucose sensor in an exploded view. PB, prussian blue. (E) Minimum volume of the artificial sweat required for sensing with different sizes of the glucose sensor. (F) Scanning electron microscope (SEM) images before (left) and after (right) immobilization of the enzyme (enz.) on the porous gold electrode. (G) Comparison of the H2O2 sensitivity in the planar and porous gold electrode deposited with Prussian blue at different H2O2 concentrations. (H) Schematic of the drug-loaded microneedles. The right inset describes details of different PCNs. (I) SEM image of the microneedles. (J) Confocal microscope images of the released dye from microneedles (MN) (top view) into the 4% agarose gel (green, agar; red, dye). (K) Infrared (IR) camera image of the three-channel (ch) thermal actuator. Hyunjae Lee et al. Sci Adv 2017;3:e1601314 Copyright © 2017, The Authors

Fig. 2 Optimization of the sweat control and characterization of individual sensors. Optimization of the sweat control and characterization of individual sensors. (A) Optical image of the wearable sweat analysis patch with a sweat-uptake layer and a waterproof band. The inset shows the magnified view of the porous sweat-uptake layer. (B) Optical image of the sweat analysis patch under deformation. (C) Optical image of the disposable sweat analysis strip on human skin with perspiration. (D) Glucose (glu.) concentration measurement at different sweat volumes (0.3 mM glucose in artificial sweat). (E) Optical image (top) and calibration curve (bottom) of the humidity sensor. Inset shows the image before and after wetting of the sensor. (F) Optical image (top) and calibration curve (bottom) of the glucose sensor. (G) Optical image (top) and calibration curve (bottom) of the pH sensor. (H) Optical image (top) and calibration curve (bottom) of the temperature sensor. (I) Changes of the relative sensitivity of the uncorrected glucose sensor at different pH levels. The relative sensitivity (S/So) is defined as measured sensitivity divided by sensitivity at pH 5. (J) In vitro monitoring of glucose changes with (green) and without (red) correction using simultaneous pH measurements (blue). (K) Calibration curves of the glucose sensor at different temperatures. Hyunjae Lee et al. Sci Adv 2017;3:e1601314 Copyright © 2017, The Authors

Fig. 3 Characterization of PCNs and PCN-loaded microneedles. Characterization of PCNs and PCN-loaded microneedles. (A) Schematic illustration of the PCN. HA, hyaluronic acid. (B) Cryo-TEM image of PCN1 (palm oil) below the melting temperature (left) and TEM image of PCN1 above the melting temperature (right). (C) Cryo-TEM image of PCN2 (tridecanoic acid) below the melting temperature (left) and TEM image of PCN2 above the melting temperature (right). (D) Dynamic light scattering size measurement of PCNs at 30° (skin temperature), 40°, and 45°C. (E) Optical image (left) and confocal fluorescence (FL) microscope image (right) of PCM-coated microneedles. Microneedles contain dye-loaded PCNs for imaging. (F) Microneedle dissolution test in PBS before (left) and after (right) the PCM coating. (G) Mechanical strength test of microneedles in their dry and wet states. (H) Confocal microscope image of microneedles penetrating into 4% agarose gel (left) and IR camera image of the thermal actuation on the gel (right). (I) Drug-release profile from microneedles. (J) IR camera images of eight different spatiothermal profiles using the three-channel thermal actuator for multistage drug delivery. (K) Multistage drug-release profile. a.u., arbitrary units. Hyunjae Lee et al. Sci Adv 2017;3:e1601314 Copyright © 2017, The Authors

Fig. 4 Sweat-based glucose monitoring and feedback therapy in vivo. Sweat-based glucose monitoring and feedback therapy in vivo. (A) Optical camera image of the subject using a cycle ergometer for sweat generation with the wearable patch on the subject’s arm. (B) Real-time humidity monitoring to check the accumulation of sweat. (C) Multimodal glucose and pH sensing to improve detection accuracy. (D) Measured sweat glucose concentrations (n = 3), pH levels (n = 4), and corrected sweat glucose level (n = 3) based on the averaged pH (dotted line, glucose concentration measured by a commercial glucose assay). (E) Optical camera image of the disposable strip-type sensors connected to a zero insertion force (ZIF) connector. (F) Optical camera images of the sweat uptake via the fluidic channel of the strip. (G) Humidity monitoring of the disposable strip using impedance measurements. (H) Sweat glucose and pH monitoring using the disposable strip. (I) Ratio of sweat glucose concentrations (n = 3) measured by the patch and a commercial glucose assay with and without the pH-based correction before and after a meal. (J) Comparison of the sweat and blood glucose concentrations before and after a meal. (K) Optical camera image of the transdermal drug delivery device on the db/db mouse. (L) Blood glucose levels of the db/db mice for the treated groups (microneedles with the drugs) and control groups (without the patch, microneedle without the drugs) (*P < 0.05, **P < 0.01 versus control, Student’s t test). Hyunjae Lee et al. Sci Adv 2017;3:e1601314 Copyright © 2017, The Authors