Shrink-fit Turbine Coupling – a revolution and a revelation

Slides:



Advertisements
Similar presentations
Superior Turbine Solutions, Inc. Steam Path Capabilities Rotor Repair
Advertisements

1 Copyright Electric Power Research Institute 2008 Steam Turbine-Generator Guidelines Quick Start VolumeContent 1General Practices Condition assessment,
Improving Efficiency & Reliability
What is a fastener? A device to locate or hold parts
Grinder Safety Applications in Agriculture Shops OSHA Standard(s) and Produced by Idaho State University Office of Workforce Training.
Fork Inspection & Maintenance TM. Fork Inspection & Maintenance Forks are a critical part of the everyday operation of lift trucks. The stresses, strains.
Lubrication Of Roller Bearings. Roller Bearings have a long history around 700 BC AC around 3000 BC.
Yamaha oil pump rebuild
MyLock 644D Service Seminar.
Guardian & Vortex Shedder Sealing System Presentation
BHEL, POWER SECTOR – TECHNICAL SERVICES (HQ), NOIDA
Introduction to FLUID COPLING.
1. 2 Safety work-stoppage PDO & its contractors have suffered THREE high potential incidents involving cold cutting in the last TWO months.
WELCOME.
Charging System Service
AUTOMATIC LATHES These are machine tools in which components are machined automatically. The working cycle is fully automatic that is repeated to produce.
What is a Turbine ? A Turbine is a device which converts the heat energy of steam into the kinetic energy & then to rotational energy. The Motive Power.
Rolling element bearings A. Lozzi 09
Synchronous Induction
Motor Testing (Motor Only)
Crosshead Crosshead pin connects piston to the connecting rod. On either side of the crosshead pins are mounted the crosshead slippers (or shoes). The.
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
Problem-1: A rigid coupling has a bore diameter of 50 mm. Four machined bolts on a bolt circle of 125 mm diameter and fitted in reamed holes. If the bolts.
High Speed Balancing in the Service Industry – Deformed Rotors
The Tools we use.
CMS LEWA LDE1/M500 CO 2 pumps N° N°
SEMINAR ON ISLANDING BY PAWAN. What is islanding? Normally all Power generators are interconnected to form a network called ‘GRID’. Some times it so happens.
Circuits. Reviewing terms The Electric Force and the Electric Field The force between charged objects is an electric force. An electric field is the.
Networking Objectives Understand what the following policies will contain – Disaster recovery – Backup – Archiving – Acceptable use – failover.
MACHINE OPERATION.
CH 6.5 Electric Power Tools.
Manual Drivetrains and Axles
Parts Pinion Drive Gear: transfers power from
Motor Parts Screws (2) Bearing Thrust Gap Adjuster Exploded View
SGFP 22 Coupling On 5/26, identified excessive concentric offset for the 22 SGFP coupling (67 mils in horizontal direction) FMEA was developed which identified.
MAGM 262 Hydraulic Seals Mr. Conrado.
Maria’s Restaurant Chapter 3 Section 13
OBJECTIVES Explain the factors that cause rotor damage.
OBJECTIVES Discuss the procedure recommended for brake drum removal.
THE PROCESS OF CRACK INITIATION AND ITS PROPAGATION
Fans & Heaters technical seminar
Vertical Bandsaw Parts & Accessories.
Crane safety and inspections
Symptoms of a Failing Wheel Hub Bearing.
Common Symptoms of Damaged Wheel Bearing
Chapter 13 Offhand Grinding. Chapter 13 Offhand Grinding.
Lift-Type (the sweep surface faces the wind)
Electric braking Powerpoint presentation by:- Poonam sharma
Crane safety and inspections
1 BOLTING ASSEMBLY TRAINING - INTRODUCTIONNotes from the Training Course on Bolting Assembly BOLTED JOINT ASSEMBLY WIND ENERGY FIELD SERVICE TECHNICIANS.
BOLTED JOINT ASSEMBLY WIND ENERGY FIELD SERVICE TECHNICIANS
BOLTED JOINT ASSEMBLY COMMON WIND TURBINE BOLTING APPLICATIONS
Section 2: Movements of the Moon
BOLTED JOINT ASSEMBLY WIND ENERGY FIELD SERVICE TECHNICIANS
BOLTED JOINT ASSEMBLY COMMON WIND TURBINE BOLTING APPLICATIONS
Flip The Long House Let’s imagine the Long house example in Manual J has undergone a house flipping/energy savings update. The insulation was increased,
1 BOLTING ASSEMBLY TRAINING - INTRODUCTIONNotes from the Training Course on Bolting Assembly BOLTED JOINT ASSEMBLY WIND ENERGY FIELD SERVICE TECHNICIANS.
Induction Motor Drives
Diaphragm Valve Maintenance Instructions
What is a Turbine ? A Turbine is a device which converts the heat energy of steam into the kinetic energy & then to rotational energy. The Motive Power.
High Speed Balancing in the Service Industry – Deformed Rotors
Crane safety and inspections
Crane safety and inspections
B-Trees.
BOILER PROTECTION AND INTERLOCKS
SEVERE OIL LEAKAGE THROUGH BEARING PADESTAL
Mechanical Housings Design of a housing begins when the other elements of a mechanism have been already designed in every detail: with the shafts and axles.
Manual Drivetrains and Axles
WELCOME TO TURBINE & ITS AUXILIARIES KNOWLEDGE GROUP PRESENTATION by madhukar srivastava, se (m), ktps, dvc.
FAILURE OF BARRING GEAR CLUTCH ASSLY COUPLING
Presentation transcript:

Shrink-fit Turbine Coupling – a revolution and a revelation 11/09/2019 Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The Damaged LP Front Coupling DAMAGED LP FRONT COUPLING FLANGE Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The Damaged LP Front Coupling COUPLING MACHINED UPTO THIS POINT RUBBING MARKS ON LP FRONT COUPLING Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

Power Sector Western Region What caused it? AUXILIARY BEARING IN PEDESTAL NO.2 Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

Power Sector Western Region The cause of the damage Apparently, the cause of the damage can be attributed to a drop in the voltage in the 220V Battery System. When AC Supply failed and the DC tried to take over, this drop in the voltage resulted in start and immediate stop of the DC Oil Pumps, there by creating a temporary oil starvation to the bearings. When this incident occurred, the Unit was at 50MW load and was slated to touch full load in a few hours. This resulted in the machine coasting down to “Zero” Speed in under 4 minutes. When this happened, the babbit material from all the bearings melted and the rotor rested on the bearing shell. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The cause of the damage (Contd.) During the process of coasting down, as the babbit metal melted, the gap between the LP Front Coupling and the Auxiliary Bearing in Pedestal No.2 went on reducing. This gap is usually kept at 5mm . The minimum thickness of the babbit material at the point where the rotor rests on the bearings is usually 8mm. From this it can be deduced that, as the babbit metal melted down 5mm, the LP Coupling came in direct contact with the Auxiliary coupling. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

Power Sector Western Region The consequence This kind of a rubbing and damage to the coupling was unprecedented in the history of BHEL. As can be seen from the slides, 12 round spots corresponding to the 12 nos. of Coupling Bolts, were formed. These spots were formed in the area of the nut, as, there is always an annular space between the nut and the coupling and the thickness of the coupling flange in this area is less. The LP Rotor was then sent to the works of BHEL Hyderabad for repair. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The consequence (Contd.) The hardness of the LP Coupling Flange in all these areas exceeded 450BHN (it is normal to have the hardness between 250-300BHN) and any amount of heat-treatment and skin cutting did not yield results. It was calculated that a cut of up to 4mm on the coupling flange would be safe operationally. This too proved futile. Besides, the damage to the coupling, there were quite a few other damages, but none of this kind. Every other damage was repairable. Since the damage to the LP Front Coupling was unprecedented, the repair procedure too had to be unprecedented. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The Shrink-fit LP Front Coupling Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The repair and Commissioning The normal LP Rotor Coupling is an integral part of the Rotor and is machined from the Rotor Forging itself. Discarding the entire LP Rotor and manufacturing a new one, not only meant a huge loss of money, it also meant a 5 month delay as the minimum time required for manufacturing a new LP Rotor is 4-5 months. Thus was born, the idea of shrink-fit coupling. As the hardness of the coupling flange showed no signs of reduction, the damaged portion of the coupling was machined right upto the base. A new coupling hub with an interference of 2.0mm was fitted to the shaft. This coupling, as per the calculations of BHEL Hyderabad, could generate a power of approx. 250MW. Since the MCR of the machine was 125MW, this was within a safe range. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The repair and Commissioning Being the 1st such instance of a Turbine Coupling for machines of higher rating having been shrink-fitted, it was greeted with the usual skepticism associated with such a change. As is common in such cases, when the rotor was received at Site, it was inspected in every which way in which it could be rejected. After repair, the LP Rotor was received at site on 14.03.2010 from Hyderabad works. It took 14 days for site to carryout the following activities before putting the machine on Barring Gear: Placement of LP Rotor and checking flow-path clearances. Since there was minor distortion to LP Guide Blade Carriers, which too were sent to Hyderabad for repairs, the clearances of LP Diffuser too got affected. This required grinding of the diffuser halves. This alone took 4 days. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The repair and Commissioning … Contd. b. Alignment, Coupling and Swing Check before release for Reaming and Honing of HP/LP Coupling. c. Reaming, Honing, fitting of new coupling bolts (Since new coupling bolts were required to be installed, this necessitated machining & balancing), CRO and Swing Check. d. Alignment of LP-Generator Rotors, coupling and CRO. (These coupling bolts & nuts were not changed; hence, there was no need of Reaming & Honing). However, a machine cut on the LP Rear Coupling face was made at the works of BHEL Hyderabad which resulted in higher CRO. This was corrected by scrapping the coupling face. 2 days were lost in this activity. e. Box-up of LP Turbine f. Box-up of Generator Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

The repair and Commissioning … Contd. g. Alignment of Generator & Exciter and Swing Check h. Box-up of Exciter. i. Preparation of all keys. j. Box-up of all pedestals for flushing through pedestals. k. Normalisation of bearings and Box-up of pedestals after oil flushing The machine was put on Barring Gear on 29.03.2010, and synchronised on 02.04.2010. It was observed that the vibrations were slightly higher than before but well within limits, prompting one to believe that this was probably because of the shrink-fit coupling. Shrink-fit or otherwise, a rotor subjected to such high stresses as a result of the instantaneous stop, would even otherwise have vibrations on the higher side. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

Power Sector Western Region Conclusion This is a revolution because, this is the 1st time that BHEL has undertaken a repair job of this type. This is a revelation because, it was not known until then that Turbine Couplings too (like BFPs & CEPs) can be shrink-fitted. The gap between the Coupling and the Auxiliary Bearing provided in the pedestals should be kept at a minimum of 10mm whereby, even in the event of complete melting down of the babbit material, the coupling would remain unaffected. A safe and sound DC System should be ensured before rolling the machine. Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019

Power Sector Western Region Exploring Heights ..................... Setting Standards .................... Marching Towards Excellence Power Sector Western Region 11/09/2019