Current Meter Maintenance Model OSS-B1 Hydrographic Basics Training Course No. 27743.

Slides:



Advertisements
Similar presentations
Informações Técnicas Engenharia de Aplicação - BGL 1 Preparation before assembling Keep the assembling area dry and dust free. Check the shaft, housing.
Advertisements

USER MAINTENANCE.
Current Meter Maintenance Model OSSPC1 Hydrographic Training Bandar Seri Begawan Brunei August 2010.
NORTH POWERED AIR-PURIFYING RESPITATOR (PAPR) INSTRUCTIONS FOR USE Preventive Medicine Industrial Hygiene Service.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions Edvotek Set Up 12 groups.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Current Meter Maintenance HS Model OSS-B1 Hydrological Services Pty Ltd Presented to HiQ Engineering Brunei JULY 2009.
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
Changing the Oil in a 2006 Mitsubishi Eclipse. Introduction Changing the oil in your 2006 Mitsubishi Eclipse is easier than you may think. With a few.
Procedures For Cleaning A Revolver By Sherry L. Goucher, Sr. CTO Oklahoma Dept of Corrections District V – Community Corrections Approved on July 9, 2001.
Prestige ex 2000 TECHNICAL MANUAL 2ND STAGE
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Stanley DS11 Diamond Saw.
Cooling Tower Maintenance Training.
A Manual for Repair and Maintenance Technicians 1ST STAGE.
Yamaha oil pump rebuild
Washing & Clean-up 4-H Foodstand 2014 BC WI 4-H Food Stand. Washing & food safety1.
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions VWR Set Up 12 groups Mira Costa kit.
Tracheostomy Cleaning Guidelines (All Information taken from individual manufacturer’s guidelines) Arcadia Cleaning Soak the tube for 60 minutes in warm.
Sanitation Procedures Entry-Level Training Module I Lesson One.
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
860 (LF), 880 ½”- 2” 860 (LF), 880 ½”- 2”. Modification Overview  Production of the ½ - 2” 860 series began in 1997 and is current.  The 880 is an “N”
July 2008 Jonathan Sommer.  Has two modes to view samples Optical mode (white light) and Fluorescence mode  Depending on your sample either mode maybe.
If you use your computer more than a few hours per day, we suggest you not to turn off your computer at the end of the day. Instead turn off only the.
Pellet Dies: User Instructions Read these instructions carefully before beginning work. Read the risk assessment. If you have not used the die and hydraulic.
Basic cleaning procedures
Wheel Bearing Service. - Remove the cap using a flat head screw driver or pipe pliers. Careful not to damage the cap.
ENGINE CLEAN OIL TOOL OIL RX • 999 TRAINING
Chapter 11, Section 3. Interior Installation Installing a curtain rod Mounting Venetian blinds Mounting a window shade Hanging a picture.
Small Engine Reassembly Briggs & Stratton OHV
Tru Count Air Clutch Maintenance
Bearings -Disassembly &Assembly Nizwa College of Technology.
Hand Washing. Why do we wash our hands? We wash our hands to get rid of the bad germs that make us sick and stop the germs from spreading to our friends!
New Mexico FFA Agricultural Mechanics Career Development Event Engine Power.
P H S A U T O M I V E ALS Lubrication.
Optimizing your handpiece life! By The Dentist’s Choice.
MECH1200 SEALS, GASKETS & SEALANTS. MECH1200 WHAT CAUSES LEAKS Causes of leakage –Worn or damaged seals –Worn or damaged gaskets –Worn or bent parts or.
USA ZAMA BASIC BIS. USA ZAMA What is BIS ?  What does BIS mean? – BIS is an acronym for B alanced I dle S ystem – The BIS system is part of the idle.
Tempest Blower SECTION: Tools and Equipment ISSUED: REVISED: ##-####
General user guidelines New users –Notify the lab ( –Go over lab protocol slides –If in doubt, ask Sign up for.
Clearing Procedures. DISASSEMBLY Major Groups Barrel Group Turn the cover latch and raise the cover group Grasp the retracting slide handle with the.
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
LF866 2½”-10”. Product Overview  Production of the 2½” – 10” sizes began in  The LF866 utilizes a Type 2 bypass (Model LF619 single check).
Foods & Nutrition Sanitation & Clean Up Procedures AKA = Dishwashing 101.
Dishwashing Supplies needed Hot water A sink or pan for washing dishes A place to drain dishes Hand dishwashing detergent Non-scratch pad for stuck on.
NOW IT IS TIME FOR CLEAN UP! DISHWASHING BY HAND.
Rescue Support System Paratech. Acme Thread Strut System Paratech Strut System.
Hub and Wheel Bearings Wheel bearings allow the wheel to turn freely. The bearings may be either tapered roller bearings or ball bearings. If the spindle.
AVIVA™ ELECTRIC BIKES VIPER ASSEMBLY INSTRUCTIONS Aviva™ - For A New Way Of Life.
NorthstarRecycling.com Place materials like the following in this container for cardboard recycling: Corrugated Sugar Bags White Cardboard Brown Cardboard.
Universal Current Meter Training Model OSS-B1 Hydrological Services Pty Ltd Available for rent from Tech-Rentals.
TASK Maintain an M16-Series Rifle. TASK Maintain an M16-Series Rifle.
Manual Instructions Installation Cleaning Instructions
Copyright © 2016 by The S.E.A. Group
Bilge Pump Service Project Model Service Kit
Giving your Trombone a Bath
Instructor Notes Once you have designed a sanitary facility, it is important to keep it that way. If you do not keep the facility and equipment clean and.
Engine Lubrication Systems
Gel Electrophoresis Teacher Instructions BioRad Set Up 12 groups
830, 831 4”- 6”.
CHAPTER 45 Engine Lubrication.
Engine Oil Changes.
Engine Oil Changes.
Wednesday, 9/7 Day 2 2- Fill out your Agenda. Science Starter:
Delphi Fuel pump. Overshoot protection screw. No load throttle adjust
BOP FLUID FLUSHING SIMON McMANUS WM CANNING LTD.
850 (LF) ½”- 2”.
Giving your Brass Instrument a Bath
Or, how to be a good camper…
STUDIO MAINTAINANCE.
Presentation transcript:

Current Meter Maintenance Model OSS-B1 Hydrographic Basics Training Course No

Section 1 Prior To Discharge Measurements

Prior To Discharge Measurements Remove fan assembly from carry case Turn fan carrier anti- clockwise Anti- Clockwise

Prior To Discharge Measurements Separate fan carrier from shaft assembly (keep away from contact with any dirt particles) Hold the fan upright and fill with approved HS current meter oil Use Lint Free Tissue

Prior To Discharge Measurements Replace axle and fan carrier, excess oil will be forced up through the capillary gap around the axle, ensure fan carrier is tightened Wipe the excess oil of the meter using lint free paper towel Clockwise

Prior To Discharge Measurements Do not forget to close the oil bottle straight after usage to avoid contamination of the oil Slide the fan assembly into the body and use the stubby screwdriver to tighten the retaining screw to lock the fan assembly in place

Prior To Discharge Measurements Prior to spin test hold the current meter in the horizontal position and spin by hand for approx. one minute to get rid of the hydraulic pressure Spin test the meter against time to test the performance of the shaft and bearings

Prior To Discharge Measurements Spin test results are dependent on the fan type Connect your current meter to the counter using the lead provided (this will test that the lead, reed switch and counter are working prior to use) If the current meter fails the spin test, disassemble and clean all components again. If the current meter continues to fail the test, replace bearings OSS-B1 Spin Test Fan No.Minimum Time (secs) 190 A

Section 2 During and After Discharge Measurements

During and after Discharge Measurements After every discharge measurement, (or one hour of use), the current meter should be cleaned and refilled with oil, if continuing a discharge measurement.

During and after Discharge Measurements Undo the cleaning jar cap and ¾ fill with white spirit Remove fan assembly from meter body by undoing the retaining screw and separate the body from the fan Cleaning Jar

During and after Discharge Measurements Remove fan carrier and shaft assembly (do not place in contact with dirt particles) Empty the old oil in a recycling container and dispose (do NOT re-use)

During and after Discharge Measurements Put the shaft and bearing assembly into the cleaning jar. Agitate the jar Fill up the fan with white spirit, place your thumb over the hole and shake vigorously for a few seconds. Current meter body should be wiped clean with white spirit (there is no need to immerse)

During and after Discharge Measurements Blow dry the shaft assembly, fan carrier and fan. Re-assemble the fan, coat bearings with a small amount of oil if discharge measurement is complete

During and after Discharge Measurements Wipe box clean and return the fan assembly to the case If continuing a discharge measurement, refill the fan with oil

During and after Discharge Measurements Spin test the current meter against time as shown in section 1 After the spin test is performed connect your current meter to the counter using the lead, to test the lead, reed switch and counter.

Section 3 Office Cleaning

Office Cleaning Office cleaning should be performed on a monthly basis or whenever the meter is dirty

Office Cleaning Separate fan carrier from shaft assembly Current meter body should be wiped clean with soapy water (there is no need to immerse) Anti- Clockwise

Office Cleaning Separate fan carrier (1) from shaft assembly (2) 12

Office Cleaning Remove Nut Remove Bearing

Office Cleaning Remove Outer Spacer Remove Inner Spacer

Office Cleaning Remove Bearing Fan assembly fully dismantled ready to clean

Office Cleaning Place items in sink, filled with hot soapy water, soak for at least 5 minutes Clean items with a bottlebrush cleaner

Office Cleaning Cleaning FanCleaning Fan Carrier

Office Cleaning Cleaning outer spacer Rinse full assembly with tap water

Office Cleaning Place full assembly on lint free tissue Ready to dry and re- assemble Rinse all items in white spirit prior to re-assembly

Office Cleaning Dry Fan Carrier Dry Fan

Office Cleaning Dry Outer Spacer Dry Inner Spacer

Office Cleaning Blow Dry Bearing & Nut

Office Cleaning Start Shaft Assembly, Bearing First Assemble Inner Spacer

Office Cleaning Assemble Outer Spacer Assemble Bearing

Office Cleaning Assemble axle nut Dip shaft assembly in white spirit to lubricate bearings

Office Cleaning Blow Excess White Spirit Assemble Axle With Fan Carrier

Office Cleaning Re-assemble fan and place in carry case Clockwise

Section 4 Calibration

Calibration AS 3778 Measurement of water flow in open channels, Part 6.1, Section 7.6 Recalibration states: AS 3778 Measurement of water flow in open channels, Part 6.1, Section 7.6 Recalibration states: Meters shall be recalibrated whenever their performance is suspect. In practice, for individually rated meters, recalibration is sometimes carried out at yearly intervals or after 300 h of use, whichever is the shorter.

Questions?