Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
Integrated Technology!
NetSure™ RDB Series.
EMerge Browser Managed Security Platform Module 2 Hardware install.
GS3055-I GSM Universal Wireless Alarm Communicator
Trouble - Shooting ELR - Electric Latch Retraction.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
ONYX Digital Voice Command
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Cabinetry.
EST3 Network Communications
Training.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
ONYX Product Overview.
INTRUSION ALARM TECHNOLOGY
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
NOTIFIRE NETWORK.
RP-2000 Series Deluge & Agent Releasing Panels
High Speed NCM (HS-NCM)
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
PROFIBUS wiring/installation can be done with:
NOTIFIER® ONYX® Series Overview
NFS System Components & Installation.
2HONEYWELL - CONFIDENTIAL File Number ACM-24-AT Series A1P1 A1P2 A1P3 A1P4.
High Sensitivity Smoke Detection
DIGITAL VOICE COMMAND (DVC)
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
Intelligent Control Panel SLC
NFS System Components & Installation.
Hardware Training Product: ITMS2.
ADT490 TroubleShooting Locating Opens. 2 Power Supply Grounding Power Supply has circuit -> allows positive & negative outputs to float relative to ground.
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
New product introduction:
2 Wire Door Entry System (DES of MH BT offer)
06/18/04 1 Analog Audio Hardware and Operations. 06/18/04 2 Module 5 Objectives Upon completion of this module, the student will be able to:  Explain.
LED1 LED2 LED8 LED9 LED7 LED6 LED5 LED4 CON1 CON4 CON2 CON3 CON5 CON6 A00380 Control Board LED10 JP12 JP10 JP11 LED11 LED12 LED13 LED14 A00380 LED’S.
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
Draft UniNet-ID Sales Training For ESD Sales People & Estimators.
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
Solid State Amplifier Controller and Sequencer Jeff Millar, wa1hco.
Team Members: ECE- Wes Williams, Will Steiden, Josh Howard, Alan Jimenez Sponsor: Brad Luyster Honeywell Network Traffic Generator.
Poseidon 4002 Rack monitoring.
NEW RMC Rack Multi Control.
Network Video Switching Control System Presentation
Hardware, Installation & maintenance
System Network Structure
Redundancy Switching Components
Connections Topology of Apollo ACS.
Understanding Olympian Generator Set Schematics
GROUND-FAULT GROUND-CHECK MONITOR
230 Yuma Street Denver, CO (800)
The FG series of explosive and toxic gas detectors and panels
High Security and Access Systems
NSA-7000 Stylish flush mount Network Sensors
Multi Channel Interface & Basic Amplifier
Radiation- and Magnet field- Tolerant Power Supply System
Multi Channel Interface & Basic Amplifier
PAVIRO - Introduction Security Systems
Module 1 – Power Supply AMC APS-PBC-60
Reliable Fixed-Zone Systems
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Building a 2 KW SSPA for 23cm
724 Temperature Calibrator

Presentation transcript:

Honeywell Fire Systems Group

RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks 4 Set On Board Relay O/P

Honeywell Fire Systems Group TB4TB3TB2TB1 ALARM TROUBLE SUPV SCTY TB7 ACS TB9 RDP TB5 PRN TB6 +24V J4 BACKLIGHT J2 LCD J9 KEYPAD J13 AMPS-24 J6 SCTY J5 TROUBLE J1 NUP J7 SLC

Honeywell Fire Systems Group Display & Function Keys Function LEDs Function Keys

Honeywell Fire Systems Group TO NEXT LCM FROM CPU J7 or LCM SLC WIRING LEM CONNECTION

Honeywell Fire Systems Group Loop Modules J3 J1 J2 JP1 D33 +5V D32 D28 B+ A+ B- A- SLC JP2 TB1 JP3 SW1 EG FAULT LCM-320 LEM-320 LEM Ground Fault LCM Ground Fault

Honeywell Fire Systems Group LCM Cables

Honeywell Fire Systems Group LCM/LEM SLC Connector Channel B Channel A Typical Style 4.0 Channel B Output Channel A Return Typical Style 6.0/7.0

Honeywell Fire Systems Group AMPS-24(E) Power Supply TB3 AC TB1 SLC TB2 CPU TB6 Accessory Power SW1 Configuration Switches TB4 & 5 DC SW4 Charger Selection

Honeywell Fire Systems Group AMPS-24E (New Version) AC Input: AC 220V DC Output: 24VDC, 5A for CPU 24VDC, 3A for External Devices Battery Charger: 24VDC 7 – 200AH

Honeywell Fire Systems Group Base Address Setting

Honeywell Fire Systems Group Properties setup via software kit

Honeywell Fire Systems Group Setup Battery and Charger Current

Honeywell Fire Systems Group APS2-6RE – Auxiliary Power Supply AC Input: AC 220V DC Output: 24VDC, 3A (2 set) 24VDC, 6A (1 set) (Total 24VDC, 6A)

Honeywell Fire Systems Group Addressable Charger Power Supply ACPS 610(E) AC Input: AC 220V DC Output: 24VDC, 1.25A x 4 Circuits Battery Charger: 24VDC 7 – 200AH

Honeywell Fire Systems Group LCD-160 Remote Display TB1 RDP Bus 12 to 18 AWG Max 4K feet total Max 100 ohms TB2 24v Power From AMPS-24 From APS-6R Max 10 ohms SW17 #1 ON: Prog #2 ON: ELR 160 character display Custom graphics Tactile keypad DCC participation

Honeywell Fire Systems Group ACM (AEM) – 48 A A1P1 A1P2 A1P3 A1P4 ACM(AEM)-24AT ACS Annunciators

Honeywell Fire Systems Group ACS Annunciators ACM-8R LDM-32 series

Honeywell Fire Systems Group ACS Annunciators Switch Group 5 Switch Group 6 Switch Group 7 Switch Group 8 Switch Group 1 Switch Group 2 Switch Group 3 Switch Group 4 All Auto Manual Acknowledge SCS-8 Smoke Control Station

Honeywell Fire Systems Group Smoke Control Station Up to four modules/group Three position toggle switches –On / Off / Auto Control On Control Off Monitor On Monitor Off SCS-8

Honeywell Fire Systems Group Network Communications Module To communicate with another Onyx control panel on a network, the Onyx Panels requires an Network Control Module. The NCM is capable of working on a either a wire or a fiber network. NCM-W (Wire) NCM-F (Fiber optic) Mounting Options: In a standard Chassis position. On the right side of a DAA Audio Amplifier. Underneath the DVC Digital Video Controller. NCM-W

Honeywell Fire Systems Group A B Network Node A B Network Node or RPT A B Network Node or RPT A B Network Node Point-To-Point Configuration A point-to-point wiring configuration is defined as a twisted- pair segment with only two nodes/repeaters attached to it. Terminating resistors are required at each end of every segment, and are built into each MIB/RPT/NCM.

Honeywell Fire Systems Group A B Network Node or RPT A B Network Node or RPT A B Network Node or RPT A B Network Node or RPT Point-To-Point Configuration Wiring a Noti-Fire-Net in NFPA Style 7 point-to- point.

Honeywell Fire Systems Group CPU-3030D or CPU-3030ND Both CPU options require a CHS-M3 chassis for mounting in the top position of the cabinet. SBB-D4 D-Size Backbox CPU2 mounting LCM/LEM and NCM-W/F can be installed in the two right- hand positions. BATTERY AMPS-24(E)

Honeywell Fire Systems Group CHS-4L CHS-4L Chassis, low profile, 4 positions for mounting the LCM/LEM, NCM-W/F, APS-6R, LDM-32, BACNet GW... D-Size Backbox

Honeywell Fire Systems Group Dress Panels & Plates * Use to BMP-1 Blank Module plate to cover unused single positions DP-1B Blank Dress Plate, 4 row ADP-4B Annunciator Dress Plate* BP2-4 Battery Dress Plate DP-DISP Display Dress Plate

Honeywell Fire Systems Group The assembly consists of a back box and a locking door with two keys. The back box and door can be ordered separately or as a complete unit. Doors may be hinged right or left. A semi-flush trim ring kit is available for each box size. Page 19 DR-A4 SBB-A4

Honeywell Fire Systems Group Page 19 SBB-B4 DR-B4

Honeywell Fire Systems Group Page 20 SBB-C4 DR-C4

Honeywell Fire Systems Group Page 20 SBB-D4 DR-D4

Honeywell Fire Systems Group ABS-4D ABS-2D

Honeywell Fire Systems Group