Secondary Gas Insulated Switchgear

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Medium-Voltage Switchgear - Then and Now -
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Premset : A New generation of MV Switchgear
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
FIPTMV Medium Voltage Technology
Mr. Harethe El Ouadhane IEC member for IEC MT14. |Infrastructure Business | Germany | Test Engineer & Expert (Internal Arc, Making, Breaking.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
Multi-function apparatus for secondary distribution
Single Phase IEC and EATS Distribution Transformers
THE ELECTRIC SUB STATION
Pole Mounted Switch Disconnector NPS
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
MNS Sprint - A Market Driven Solution
Ordering Tool Guideline
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
A low - cost high performance MV RMU with circuit breakers for use in remote controlled MV / LV substations Fabio GIAMMANCO Luca GIANSANTE 1 1.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
PowerIT Air Insulated Cubicle Uniswitch
Distribution Systems-General
Switchgear for Primary Distribution
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Asahi Switchgear Products Ltd. (ASPL) is a joint venture between Hirose Co. Japan and ASABHANU Technical Services Ltd., (ABTS) India. Asahi is located.
PPU TERANG HATI PROJECT POWER DISTRIBUTION ENGINEERING (EPEB453)
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
Md.Hamidul Haque ID: Prog:BSEEE SEC:E/3 International University of Business Agriculture and Technology (IUBAT )
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
© ABB Group October 1, 2016 | Slide 1 DynaPeaQ ® SVC Light ® with Energy Storage FACTS.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Sub Station.
SUB-STATIONS.
SIGENTICS HV Series S-modyn
Chapter # 25 Sub-Stations risemark.pbworks.com.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Power Generation and Distribution
Sectos NXB and NXBD.
Oliver SCHROEDEL, Michael SCHWAN, Sven KOEPPE, Robert ROSENBERGER
Basics of electrical engineering
Name, department/event, date
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Overview Key diagram of 220 KV Sub station, Ablowal Cables
SION Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
Engineering Project Cable Management.
ELECTRICAL POWER-II Electrical engineering sixth semester
Low Voltage Products division
All rights reserved Gas-insulated Switchgear (GIS)
3AH5 Vacuum Circuit-Breaker For Standard Applications
The smart choice for demanding motor switching
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

Secondary Gas Insulated Switchgear SafeLink CB 12kV SGIS

SafeLink CB Contents Ring Distribution & Secondary Network SGIS Application Operating Conditions SafeLink CB Portfolio, Parameters & Dimensions & Variations Product Safety Cable Termination & Extension Protection, Indication & Measurements Digital (Smart Secondary Switchgear) Manufacturing Facility End-of-life & Environmental Certification

Ring Distribution System SafeLink CB Ring Distribution System Concept & Advantages In the event of fault in Underground Network, appropriate measures are required for quick fault location and isolation. Unlike Radial distribution system for system redundancy, Ring Topology of using RMU can still reduce downtime equally & still remain economical. Ring Main Units are deployed in a manner, that every load centre in the loop has an alternative source of supply available. In the event of fault, the faulty section can be isolated within minutes and supply to affected load centers can be resumed with alternative source. Detailed Simulation follows…… RING SWITCH T-OFF SWITCH Load Centre Back to Contents

Secondary Distribution SafeLink CB 400 kV Secondary Distribution Transmission substation Thermal Hydro Transformer 130 kV Renewables Infrastructure 40-70 kV Main substation 400 V Distribution substation 36kV - 24kV – 12kV Secondary substation Industry Back to Contents

Ring Distribution System – Normal Condition SafeLink CB Ring Distribution System – Normal Condition 33/11kV 33/11kV Normally Open Points Local Receiving Stn. Local Receiving Stn. Back to Contents

Ring Distribution System - Faulty Condition SafeLink CB Ring Distribution System - Faulty Condition FPI’s Indicate path of fault current 33/11kV 33/11kV Local Receiving Stn. Normally Open point is closed Local Receiving Stn. Faulty Section is Isolated Fault Appears in System Grid Blackout! Back to Contents

Ring Distribution System – Restored Condition SafeLink CB Ring Distribution System – Restored Condition 33/11kV 33/11kV Local Receiving Stn. Local Receiving Stn. Supply to Load Centers is Resumed! Back to Contents

Secondary Distribution SafeLink CB Secondary Distribution Back to Contents

SafeLink CB Application Packages Back to Contents Renewables Solar Wind Industry Oil & Gas Textile & Automotive Cement & Glass Utility Power distribution utility Infrastructure & Transport SMART City & Industrial Corridors Military Engineering Services Metro & Railways Back to Contents

SafeLink CB Operating Conditions Operating Conditions Back to Contents Normal operation conditions The rated characteristics of the switchgear are valid under the following ambient conditions: minimum ambient temperature: – 25 °C maximum ambient temperature: + 40 °C Ambient humidity maximum 24 h average of relative humidity 95% maximum 24 h average of water vapour pressure 2.2 kPa maximum monthly average of relative humidity 90% RH maximum monthly average of water vapour pressure 1.8 kPa Altitude Upto 1000 metres above sea level Corrosion Class C3 for Indoor & C2 for Outdoor For different temperature ranges, higher altitudes, special corrosion class please contact ABB sales representative. Back to Contents

SGIS Product Evolution SafeLink CB SGIS Product Evolution Well proven technology Years of experience Global Product Portfolio Global Customer References 36kV 24kV 12kV 1985 Norway Plant 2003 Nasik Plant 2004 2011 2014 2018 Back to Contents

SGIS Product Portfolio SafeLink CB SGIS Product Portfolio Product Family SafeRing / SafePlus 2004 Indoor 12/24kV SafeLink CB 2011 Outdoor 12kV SafeRing / SafePlus 2006 Outdoor 12/24kV SafeRing 36 / SafePlus 36 2014 Indoor/Outdoor 36kV Back to Contents

SGIS Product Portfolio SafeLink CB SGIS Product Portfolio   SafeRing/SafePlus SafeLink CB SafeRing 36 / SafePlus 36 Indoor Outdoor Rated Voltage (kV) 12/24 12 36 Rated Current (A) 630 STC (kA/s) 21/3 25/1 Breaking Capacity (kA) 21/16 21 25 Mechanical Endurance (LBS) M1 (1000) Mechanical Endurance (VCB) M1 (2000) M1 (2000) (M2 optional) Electrical Endurance (LBS) E3 Electrical Endurance (VCB) E2 E1 IAC Classification AFLR 20kA/1s AFLR 21kA/1s AFL 21kA/1s* AFLR 25kA/1s** * - AFL 21kA/1s for Tank & AFLR 10kA/0.1s for Cable Box. Higher values available on request ** - AFLR 25kA/1s for Indoor SafeRing 36 / SafePlus 36 Back to Contents

SafeLink CB Product Portfolio SafeLink CB Back to Contents C / V / D Switching / Protection Modular Design Extremely Compact Switchgear CVC, VC, VD, V, C Extensibility on both sides 3 modules in single tank (Any combination) Motorisation/Battery back-up Versatile Bus Metering Solutions with CT/PT Integral LV Box on top of RMU Mechanism Back to Contents

SafeLink CB Technical Parameters Product Portfolio SafeLink CB SafeLink CB Technical Parameters Rated Voltage 12kV Power Frequency Withstand Voltage 38kVp Impulse Withstand Voltage 95kVp Frequency 50Hz Rated Current (RMU) 630A Rated Current (Ring Switch) Rated Current (VCB) Short Circuit Making Current (for 12kV) 52.5kA Short Circuit Breaking Current (VCB) 21kA Short Time Current (for 3s) Main Circuit Peak Withstand Current Main Circuit Short Time Current (for 3s) Earthing Switch Short Time Current (for 1s) Earthing Circuit Short Circuit Making Current (ES) Minimum Operating Pressure 1.2 bar Mechanical Endurance (Ring Switch) M1 Mechanical Endurance (Earth Switch) M0 Electrical Endurance (Ring Switch) E3 Electrical Endurance (Earthing Switch) E2 Mechanical Endurance (VCB) M1* Electrical Endurance (VCB) IAC Classification Tank – AFL 21kA/1s Cable Compartment – AFLR 10kA/0.1s Cable Compartment – AF 21kA/1s (optional) Optional Test Point Bushing Robotic Welding of SS304 Grade Tank 2.5mm Standard thickness for Tank 2mm Standard thickness for Enclosure IP 54 for Enclosure Site Replaceable Cable Bushing Compatible to Digital Upgrade (Details Follows) *M2 optionally available Back to Contents

SafeLink CB Design Philosophy SafeLink CB Back to Contents Compact and Robust Design Simulations application for design validations Personnel safety considerations Modern development and manufacturing techniques Durability and recyclable for environment Back to Contents

SafeLink CB Variations V C C SafeLink CB Back to Contents Non-extensible configurations Extensible configurations – on either sides & both sides 3way configuration CVC 2way configuration VC-VD-DC 1way configuration V-C With & Without Test Point Bushings Vertical & Horizontal Door Cable Compartment 10kA IAC version & 21kA IAC version PEX on either sides for future extensbility SafeLink CB for CSS version C C Back to Contents

SafeLink CB Design Philosophy C Module Back to Contents 3 position switch disconnector and earthing switch SF6 as arc quenching and insulating medium Cable Test Point Bushings on bottom of the tank (standard) Single spring latched mechanism for all 3 positions of ON-OFF-EARTH Cable compartments and Test Point compartments interlocked Busbar extension bushing Back to Contents

SafeLink CB Design Philosophy V Module Back to Contents VG5 interrupter from ABB Interruption in vacuum Insulation provided by gas No consumable parts Rugged and reliable 10000 mechanical endurance operations 30000 operations of VI at rated current Three position disconnector and earthing switch Back to Contents

SafeLink CB Design Philosophy SF6 Gas Tank Back to Contents Vacuum BKR aligned to T-off side with cable bushings on back side Switch cable bushings on the left & right sides Mechanisms for Circuit Breaker and Cable Switch on front Disconnector manually operated Test Point Bushings in the bottom of the tank Back to Contents

SafeLink CB Description Product Description Back to Contents Rating Plate Manometer Front Upper Mimic Relay VCB Disconnector Padlock Fault Indicator VPIS for Ring Switch RHS Ring Switch RHS Cable Box for Ring Switch RHS Test Point Box for Ring Switch RHS Switchgear Stand Earth & Circuit Slider for Ring Switch VCB Disconnector Operating Handle Door Handle Padlocking for Switchgear Front Door Switchgear Front Door Gas Spring for Switchgear Front Door Switchgear Earthing T-Off Cable Box (For VCB) Current Transformer (Directly mounted on VCB Bushings) Lifting Hook for Switchgear End Box (For extensible version only) ‘V’ module section 25. ‘C’ module section Back to Contents

SafeLink CB Dimensions Back to Contents Bushing C-C 100 mm Front Door 1830 1210 960 Bushing C-C 105 mm 2020 1540 1320 Bushing C-C 100 mm 826 Front Door Open View Back View Back to Contents

Dimensions (CVC Non Extensible) SafeLink CB Dimensions (CVC Non Extensible) Back to Contents

Dimensions (+CVC+ Both Sides Extensible) SafeLink CB Dimensions (+CVC+ Both Sides Extensible) Back to Contents

Dimensions (+V+ Both Sides Extensible) SafeLink CB Dimensions (+V+ Both Sides Extensible) Back to Contents

Dimensions (+C+ Both Sides Extensible) SafeLink CB Dimensions (+C+ Both Sides Extensible) Back to Contents

Dimensions (CVC Non Extensible 21kA IAC cable box) SafeLink CB Dimensions (CVC Non Extensible 21kA IAC cable box) Back to Contents

Dimensions (Foundation/Coupling) SafeLink CB Dimensions (Foundation/Coupling) Back to Contents

SafeLink CB Product Portfolio SafeLink CB Back to Contents V+M ICOG Solution Factory fitted solution Extremely Compact Switchgear Optional Extensibility on left side Motorisation/Battery back-up Versatile Bus Metering Solutions with CT/PT Integral LV Box below Switchgear & Metering Single Base Frame for ease in erection Tested as per IEC 62271-200, IEC 62271-100, IEC 62271-1 Back to Contents

SafeLink CB Product Portfolio SafeLink CB Back to Contents CVC+VC+, CVC+CVC+, CVC+V+, CVC+C+ Factory fitted coupled solution for 4way, 5way Optional Extensibility on both sides Motorisation/Battery back-up Versatile Bus Metering Solutions with CT/PT Integral LV Box on top of RMU Mechanism Single Base Frame for ease in erection SCADA Integrated as per latest IPDS specification FRTU/PLC with Modem factory integrated Ready for communication with different protocols Back to Contents

SafeLink CB Product Portfolio SafeLink CB Back to Contents CVC Digital Factory fitted digital solution Optional Extensibility on both sides Motorisation/Battery back-up Versatile Bus Metering Solutions with CT/PT Integral LV Box on side/top of RMU Mechanism Single Base Frame for ease in erection SCADA Integrated as per Middle East specification FRTU/PLC with Modem factory integrated Ready for communication with different protocols Back to Contents

SafeLink CB Product Portfolio SafeLink CB Back to Contents Trafo Coupled Easy fitting in compact CSS Optional Extensibility on both sides Motorisation/Battery back-up Integral LV Box on top of RMU Mechanism SCADA Integrated / Compatible Back to Contents

SafeLink CB Product Safety Internal Arc Classification Tank : AFL 21kA/1s Cable Compartment : AFLR 10kA/0.1s Tank : AFL 21kA/1s Cable Compartment : AF 21kA/1s Back to Contents

Interlocks & Padlocks SafeLink CB Product Safety Interlocks & Padlocks SafeLink CB Vacuum Circuit Breaker Ring Switch 1 Interlock Type Operation Condition Comment Mechanical Interlock - C Module Closing LBS ES is open, Cable Door is closed Standard Interlock Opening LBS ES is open Mechanical Interlock - C, V Modules Closing ES LBS/Disconnector is open Opening ES Opening Cable Door ES is closed Mechanical Interlock - V Module Closing CB No interlock   Opening CB Closing Disconnector CB is open, ES is open, Cable Door is closed Opening Disconnector CB is open, ES is open Electrical Interlock Closing/Opening - LBS/VCB As per customer request Optional Padlock Closing/Opening - LBS/DS/ES/VCB Only provision Ring Switch 2 Disconnector Ring Switch 1 & 2 Back to Contents

Cable Termination & Extensibility SafeLink CB Cable Termination & Extensibility Cable Termination Interface C (400 series) with M16 metric threads Standard for C, F, V, D, De Modules including extensibility Standard till 630A For 12kV, terminal protector shall be provided as standard For 24kV/36kV, termination kits shall be provided upto request. For more information on cable termination details, respective catalogues/O&M Manuals shall be referred Back to Contents

SafeLink CB Extensibility Extensibility Back to Contents Optional extensibility on both sides Coupling at site to existing RMU without cable disconnection Detailed Coupling Instructions available for more information Back to Contents

Protection, Indication & Measurement Solutions SafeLink CB Protection, Indication & Measurement Solutions Protection/Indication Measurements/Metering Self Powered OC+EF Relays Auxiliary Powered Feeder Protection Relays Feeder IEDs Voltage Indicators (Signalling contact optional) SC+EF Indicators Bus Metering solutions available Indoor/Outdoor Metering CT/PT as per site requirements/specification SCADA Integrated metering solutions on offer For more details, please contact ABB Sales representative Back to Contents

Manufacturing Facility SGIS Plant as selected as “Best in Class shop floor” by CNBC Info media TV18, industrial magazine 13th Anniversary SafeLink CB Manufacturing Facility State-of-Art SGIS Manufacturing Facility State-of-Art SGIS Plant in Nashik, Maharashtra, India Robotic Welding Station (ABB Robots) SCADA Automated Helium Leak Check SF6 Filling Unit Single Piece Feed Line for Tank & Finish Ergonomically designed lines for worker friendly Lean Six Sigma Methodology implemented Back to Contents

Environment Certification SafeLink CB Environment Certification End of Life & Environment Certification Life Expectancy of Products Products developed in compliance with IEC 62271-200 Design incorporates a life span of over 20 years Switchgear is gas-tight with expected leakage rate of < 0.1%/yr SF6 Gas Pressure is 1.4 bar Switchgear will maintain gas-tightness (gas-pressure >=1.3bar) throughout its designed life span. End of Life ABB committed to protection of the environment & adheres to ISO 14001 Standards ABB Obligates to facilitate end of life recycling of all ABB products No explicit requirements for how to handle discarded switchgears ABB’s recycling service is according to IEC 1634 edition 1995 section 6: «End of life of SF6 filled equipment» In particular 6.5.2.a: «Low decomposition»: «No special action is required; non-recoverable parts can be disposed of normally according to local regulations.» Back to Contents