MEASUREMENT UNCERTAINTY

Slides:



Advertisements
Similar presentations
So how good are your results? (An introduction to quantitative QC)
Advertisements

QUALITY CONTROL IN HEMATOLOGY
User verification of performance Zahra Khatami/Robert Hill BHR University Hospitals/Sheffield Teaching Hospitals Focus 2013.
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
World Health Organization
EVALUATING BIOASSAY UNCERTANITY USING GUM WORKBENCH ® HPS TECHNICAL SEMINAR April 15, 2011 Brian K. Culligan Fellow Scientist Bioassay Laboratory Savannah.
Meeting the ISO/IEC Requirements for Traceability and Measurement Uncertainty APLAC Approaches Dr Bernard King NARL, Australia.
InterQC Delivering Simplicity in the Quality Control Management for your Laboratory Developed by Vitro.
DQOs and the Development of MQOs Carl V. Gogolak USDOE Environmental Measurements Lab.
Quality Assurance in Haematology
The Molecular Diagnostics Research Laboratory University of Malaya Development and Implementation of a Quality System The Molecular Diagnostics Research.
Quality Assessment 2 Quality Control.
Copyright 2008 © Silliker, All Rights Reserved Interpretation of Lab Results What am I buying? What does it mean? What do I do with it?
ABC of Quality Control A problem based approach RT ERASMUS NHLS / FACULTY OF HEALTH SCIENCES, UNIVERSITY OF STELLENBOSCH 20th July, 2007, Bela Bela.
Development of An ERROR ESTIMATE P M V Subbarao Professor Mechanical Engineering Department A Tolerance to Error Generates New Information….
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
American Association for Laboratory Accreditation Practical Solutions to Traceability and Uncertainty in Accreditation Presented to CITAC-NCSLI Joint Workshop.
Uncertainty Estimation of Analytical Results in Forensic Analysis Ing. Ján Hrouzek, Ph.D. * Ing. Svetlana Hrouzková, Ph.D. Hermes.
Measurement Uncertainty Information in
Quality Control Lecture 5
Laboratory QA/QC An Overview.
Williams, A.: Measurement Uncertainty© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical.
Statistics & graphics for the laboratory 25 Biological variation Introduction Estimation (ANOVA application) Index-of-individuality Comparison of a result.
EGA E gyptian G erman A utomotive Co. A DaimlerChrysler Industrial J.V. 1 THE CALIBRATION.
HOW TO ASSESS THE MEASUREMENT UNCERTAINTY
QC/QA.
Metrology for Chemical Analysis
Application of Westgard multi rules in medical laboratories
Limit of detection, limit of quantification and limit of blank Elvar Theodorsson.
USE OF UNCERTAINTY OF MEASUREMENT IN TESTING ROHAN PERERA MSc ( UK ), ISO/IEC Technical Assessor, Metrology Consultant.
All you wanted to know about laboratory tests, but were afraid to ask By Dietmar Stöckl STT Consulting The informed patient meeting the laboratory.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Estimating measurement uncertainty
1 AMPS 4 22/ Brussels Discussion Paper As of , Bullet 4 Analytical Methods for Operational and Surveillance Monitoring Of WFD PS.
1 Analytical Forensic Metrology Analytical Forensic Metrology 4 th International Conference on Forensic Research & Technology September 29, 2015 Jerry.
Table 1. The Five Medical Laboratory Case Studies Jan Martin et al. Transnational Evaluation of a New Continuing Professional Development Activity for.
Setting the requirements for a method (including aspects of MU) Bertil Magnusson, SP Technical Research Institute of Sweden.
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Quality Assurance.
Method Validation-where do I start?
Challenges in Method Validation – A Regulatory Laboratory Perspective
CURRENT SITUATION AND PROBLEM OF IQC AND EQC IN INDONESIA
AMEK 2013 SCIENTIFIC CONFERENCE & EXHIBITION
Accuracy Significance in Measurement.
Internal Standard method (experiment lab-4)
Measurement Uncertainty and Traceability
Laboratory QC: Bridging the Gap Between Theory and Practice
Dr. Birgit Schmauser, BfArM, Bonn
Uncontrolled variation is the enemy of quality
By John Wilson Accreditation and Metrology Services (Pty) LTD.
Workshop Method Validation in Analytical Sciences Current practices and future challenges Gent, 9-10 May 2016 Report from WG 1 Day2.
Laboratory Quality Control
Practical clinical chemistry
Have Instrument, make method; How new methods are made and validated
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
به نام خدا تضمين کيفيت در آزمايشگاه
Analytical Method Validation
Convenor: Lorens Sibbesen
Process control in Hematology section
Calculating Uncertainties Using Data from precision & bias experiments
MECH 3550 : Simulation & Visualization
Introduction To Medical Technology
Quality Control Lecture 3
▪Internal quality control:
Multi-laboratory Method Validation
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
A proposal for Derivation of Analytical Quality Goal for Precision
LEAN LABORATORY PRACTICES
STANDARDISATION, HARMONISATION AND TRACEABILITY
Presentation transcript:

MEASUREMENT UNCERTAINTY Dr A A KHINE DIVISION OF CHEMICAL PATHOLOGY NHLS TYGERBERG STELLENBOSCH UNIVERSITY Laboratory Management workshop 3-6 June 2019

MEASUREMENT UNCERTAINTY is a parameter, associated with the result of a measurement… that defines the range of the values that could reasonably be attributed to the measured quantity (UKAS) Non-negative parameter characterizing the dispersion of the quantity values being attributed to a measurand, based on the information used.

MU is requirement in ISO standards and accreditation “The laboratory shall determine measurement uncertainty for each measurement procedure in the examination phases used to report measured quantity values on patients’ samples. The laboratory shall define the performance requirements for the measurement uncertainty of each measurement procedure and regularly review estimates of measurement uncertainty.”

WHAT COULD CONTRIBUTE TO MU?

How to estimate MU- TQM approach- not practical

Steps of the evaluation of the measurement uncertainty Time Scale BMICH

Approaches in estimating MU Definition of the Measurand Single laboratory Inter laboratory Component by Component Evaluation ISO GUM Single lab Validation Within-lab reproducility & Bias NordTest Interlaboratoy Validation Reproducibility and Bias ISO 5725 ISO TS 21748 Proficiency Testing (PT) Between Lab Variability ISO Guide 43 ISO 13528 12-Nov-2015 BMICH

ISO 15189 gives some guidance The relevant uncertainty components are those associated with the actual measurement process, commencing with the presentation of the sample to the measurement procedure and ending with the output of the measured value. Measurement uncertainties may be calculated using quantity values obtained by the measurement of quality control materials under intermediate precision conditions that include as many routine changes as reasonably possible in the standard operation of a measurement procedure, e.g., changes of reagent and calibrator batches, different operators, scheduled instrument maintenance 12-Nov-2015 BMICH

Based on assumption approach- uses imprecision from long-term IQC See NHLS QA UOM sheet Hierarchical judgement of performance- desirable, minimum and maximum analytical goals- from CVi or CVw from BV database (Westgard), then CEC endorsed CV limits When the analyte is not in the BV list, search from other sources such as RCPA, drgrhodes Optimum: CVA = < 0.25 x CVI Desirable: CVA = < 0.50 x CVI Minimum: CVA = < 0.75 x CVI Optimum: BA = < 0.125 (CVI2 + VG2)1/2 Desirable: BA = < 0.250 (CVI2 + CVG2)1/2 Minimum: BA = < 0.375 (CVI2 + CVG2)1/2

Why do we estimate MU? Reference change values (RCVs) Determines whether the difference between two results is negligible due to uncertainty or significant due to a genuine change in the condition of the patient. RCV = 2.77 x √(CVA2 + CVI2) Compare the MU and RCV to make medical decisions (but your performance must be acceptable first before you use the MU in this way) Look at Performance Index (CVa/CVi or w) if <0.5 – performance is acceptable If < 0.75 – still okay if > 0,75 – not acceptable (in this case do not report the MU, in fact so not release results. Stop testing and troubleshoot – check if you have trim out the IQC data when you print the 6 monthly data

Should we report it on the patient’s result? Different opinion What does NHLS say? What does ISO say? What are peers doing? When should we report MU and when we should not?