Fig 1. Proposed Diagnostic Reference Levels for 3  Common Cardiac Interventional Procedures: an all-Ireland Investigation  Collaborative project between.

Slides:



Advertisements
Similar presentations
Access Site Complications Nick Cheshire MD FRCS, Professor of Vascular Surgery Imperial College Healthcare St Mary’s Hospital Campus.
Advertisements

Patient Radiation Exposure: Comparison between Supine and Prone Techniques for Percutaneous Nephrolithotomy. Introduction Recent advancements in PCNL for.
The Radial Approach to Percutaneous Coronary Intervention Is Associated With a Lower Risk for Complications Regardless of Radial Procedure Volume: A Report.
Patient Dosimetry in Radiology, Management Center Europe, June
Dose Reduction in Interventional Radiology and Cardiology
NON-STEROIDAL ANTI-INFLAMMATORY DRUGS AND PANCREATIC CANCER RISK: A NESTED CASE-CONTROL STUDY Marie Bradley, Carmel Hughes, Marie Cantwell and Liam Murray.
Radiation Protection - Eyes 4 Imaging Solutions, LLC Mark Struthers BBA, BSRT (R)(MR), CMRT, CIIP.
Radiation Dose in MS-CT coronarography Ladislav Pavic, MD, PhD Sunce Clinics Zagreb / Sarajevo Croatia / Bosnia & Herzegovina.
Optimizing Patient Radiation Dose
Radiation Protection of Patients Unit
Patterns of red blood cell transfusion use and outcomes in patients undergoing percutaneous coronary intervention in contemporary clinical practice: Insights.
International Atomic Energy Agency Can cardiac procedures be graded in complexity and related with dose? L 8.3.
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
Patient-centered, Purposeful Public Reporting David Share, MD, MPH vice president, Value Partnerships Blue Cross Blue Shield of Michigan
Knowledge of radiation exposure in common radiological examinations amongst radiology department staff AL Chang, LH Cope, DH Keane, S Wood Presented by.
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
Dose Audit in Fluoroscopy Colin Martin and David Sutton.
TRI vs TFI in STEMI Shenyang Northern Hospital Wang Shouli Han Yalin.
DOES TRANSRADIAL INTERVENTION IMPACT RADIATION EXPOSURE Dr Jim Nolan University Hospital of North Staffordshire.
Radiation Sources in medicine diagnostic Radiology
Cumulative dose and skin damage
Abstract VARIABLE SELECTION FOR DECISION MAKING IN MENTAL HEALTH Lacey Gunter 1,2, Ji Zhu 1, and Susan Murphy 1,2 Departments of Statistics 1 and Institute.
Levels of Review of Research and Quality Improvement Walter Kraft, MD Associate Director, Office of Human Subjects Protection Department of Pharmacology.
Date of download: 5/28/2016 Copyright © The American College of Cardiology. All rights reserved. From: Trends in Vascular Complications After Diagnostic.
Peripheral Artery Disease in Orthopaedic Patients with Asymptomatic Popliteal Artery Calcification on Plain X-ray Adam Podet, MS; Julia Volaufova, phD,;
Date of download: 6/21/2016 Copyright © The American College of Cardiology. All rights reserved. From: Prediction of Cardiac Events in Patients With Reduced.
Impact of Anticoagulation Regimens on Sheath Management and Bleeding in Patients Undergoing Elective Percutaneous Coronary Intervention in the STEEPLE.
Blinded by the Light The irradiation of lenses during routine CT head examinations across a NHS Trust; a quality improvement project Dr Jack Roberts, Dr.
Universitätsklinikum Carl Gustav Carus an der Technischen Universität Dresden Preoperative simulation reduces surgical time and radiation exposure for.
Date of download: 6/24/2016 Copyright © The American College of Cardiology. All rights reserved. From: The Year in Cardiovascular Surgery J Am Coll Cardiol.
INTRODUCTION A major limitation of C-arm fluoroscopy is the inability to capture radiographic images in more than one anatomical plane at a time. The G-arm.
Date of download: 7/9/2016 Copyright © The American College of Cardiology. All rights reserved. From: Prediction of 1-Year Mortality in Patients With Acute.
Date of download: 7/10/2016 Copyright © The American College of Cardiology. All rights reserved. From: The Benefits Conferred by Radial Access for Cardiac.
From: Contemporary Mortality Risk Prediction for Percutaneous Coronary Intervention: Results From 588,398 Procedures in the National Cardiovascular Data.
From: Contemporary Mortality Risk Prediction for Percutaneous Coronary Intervention: Results From 588,398 Procedures in the National Cardiovascular Data.
ICRP Publication 120 ICRP, Radiological Protection in Cardiology. ICRP Publication 120. Ann. ICRP 42 (1): Authors on behalf of ICRP C. Cousins,
From: Relationship of Beam Angulation and Radiation Exposure in the Cardiac Catheterization Laboratory J Am Coll Cardiol Intv. 2014;7(5): doi: /j.jcin
Radiation Dose in Vascular Surgery Procedures
Discovery Program Cardiac Care Unit
CVVT 1201 Introduction to Cardiovascular Technology
Skin doses in cardiac intervention at St. Olav`s hospital Norway
Diabetes and Hypertension Health Screening in the Fresno Sikh Population: A Cross Sectional Approach Baljit Singh Dhesi 1,2 1University of California,
Christian Lefuare John Croft CEPN NRPB
Patient exposure trends and problems in implementing ALARA
Lako S, Daka A, Nurka T, Dedej T, Memishaj S
University of Ulster, School of Life and Health Sciences.
CURRENT TRENDS AND LIMITATIONS IN ESTABLISHING DIAGNOSTIC REFERENCE LEVELS FOR RADIOLOGICAL EXAMINATIONS IN NIGERIA The 48th Annual Conference and.
PCI related in-hospital mortality based on race and gender in the USA
Carotid Artery Stenting Predictors of procedural and clinical success
Introduction Results Materials and Methods Conclusions References
Robotics in the Cath Lab
Complication Rates for Percutaneous Coronary Intervention in South Australia Aashray Gupta1, Rosanna Tavella1,2, Margaret Arstall1,3, Matthew Worthley1,2,
Radiation in Everyday Life – an Irish Perspective
MC BROWNa, MS PEARCEa, J SALOTTIa, AW CRAFTb, J HALEb
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
How to Promote Women Awareness to Heart Disease and the Role for Women
Exhibit Number: C19 Evaluation and Reduction of Head Computed Tomography Dose Because of full frame graphic use title slide sparingly because too many.
US Army Patient Safety Center
Discovery Program Cardiac Care Unit
Daniel Fung Kevin Burns
Conduct of Film Analysis
Nat. Rev. Cardiol. doi: /nrcardio
Skin dose, effective dose and related risk in TAVI procedures –
Considerations for Percutaneous Coronary Intervention (PCI)
Diagnostic Reference Levels (DRLs) in Medical Imaging
Risk Stratification and Interventional Cardiology: Robert L
Nat. Rev. Cardiol. doi: /nrcardio
EXTENT OF CHANGES IN PRE AND POSTDONATION DONOR VARIABLES IN SINGLE AND DOUBLE DOSE PLATELETPHERESIS AND ITS IMPLICATIONS ON DONOR SAFETY Dr. R. Sreedevi.
Scatter Cloud of the C-arm
Relative risk by median risk exposure for 40-year-old men.
Presentation transcript:

Fig 1. Proposed Diagnostic Reference Levels for 3  Common Cardiac Interventional Procedures: an all-Ireland Investigation  Collaborative project between University College Dublin, Ireland & the University of Ulster at Jordanstown, Belfast. C. D’Helft, S. Mc Fadden, A. McGee, L. Rainford, C. Hughes, J. Winder & PC. Brennan PURPOSE : The number of interventional radiological procedures performed has risen in recent years because of their cost-effectiveness when compared with surgical procedures. Due to the prolonged fluoroscopic exposure times encountered during interventional procedures, cardiovascular studies are often responsible for some of the highest patient and staff radiation doses [1]. Such exposures increase the risk of stochastic radiation effects and regularly cross the threshold dose above which direct, deterministic effects are experienced by the patient [2,3]. Radiation doses for cardiac interventional procedures in Ireland are currently being compared to those recorded by the DIMOND EU project and the Health Protection Agency’s ‘National Patient Dose Database’ (NPDD). MATERIALS & METHODS : This poster illustrates some of the findings obtained from the 22 specialised adult catheterisation suites being surveyed. The work focuses on hospitals in both the Republic and Northern Ireland. Radiation dose levels and procedural information are being determined and compared for coronary angiograms (CA), percutaneous coronary intervention (PCI) and permanent pacemaker insertion procedures (PPI). Radiation dose levels are being recorded using calibrated dose area product meters. Other factors being documented include: Patient data: age, gender, body mass index (BMI); Grade of cardiologist; Projections acquired/technique employed; Equipment used; Complexity score for all examinations [4,5]; Exposure factors: kVp / mA / fluoroscopic exposure time / length of cine run / single and biplane image acquisition options. RESULTS : DAP meter readings & Fluoroscopic exposure times (hospital data combined) CA: Average: 3,786.9 cGycm² 4.3 mins Range: 136 – 23,101 cGycm² 0.22 - 27.6 mins PCI: Average: 8,136.9 cGycm² 14.5 mins Range: 475 – 41,308 cGycm² 1.8 - 98 mins PPI: Average: 1,736.6 cGycm² 6.6 mins Range: 45-17,192 cGycm² 0.33 – 54.5 mins It has been noted that due to the large number of variables possible within each procedure, that further sub categories could be separated, however this has not been done in this case as the aim is to show an average procedure. COMPARISON OF REFERENCE LEVELS : DIMOND-Values as proposed by the DIMOND EU PROJECT [6] NPDD- Values as proposed by the National Patient Dose Database set up by the NRPB now HPA. [7] CAUSAL AGENTS : Stepwise regression analysis demonstrated that in addition to fluoroscopic exposure time, body mass index and examination complexity, cardiologist grade was a significant causal agent for dose variation, with the higher doses associated with the more experienced clinician. This was not linked to the complexity of procedures and requires further investigation. Mean doses & times across the hospitals investigated for the three examinations are shown in figures 1-6. The red and green lines illustrate the combined hospitals overall mean and third quartile values respectively. A blank space represents a catheterisation suite. where the specified procedure was not performed. Fig 1. Fig 2. Fig 3. Fig 4. Fig 5. Fig 6. CONCLUSIONS : Due to the risks associated with radiation, patient dose should be kept as low as reasonably achievable, consistent with maintaining image quality. Whilst setting reference levels for these complex procedures has some difficulties, it is important that some benchmark values are available as a guideline to the operators an departmental personnel. The setting of reference dose levels and the establishment of optimum practice as investigated in this study should reduce radiation dose and image quality variation for these relatively common interventional procedures. REFERENCES 1. Vano E, Arranz L, Sastre J M, Moro C, Ledo A, Garate M T, Minguez I. Dosimetric and radiation protection considerations based on some cases of patient skin injuries in interventional cardiology. Br J Radiol; 71 (1998); pp 510-516 2. Vano E, Gonzalez L, Fernandez J M, Guibelalde E (1995). Patient dose values in interventional radiology. Br J Radiol; Nov; 68(815); pp 1215-20. J. Interv Cardiol; 17(3); pp 131-142. 3. Vlietstra R E, Wagner L K, Koenig T, Mettler F (2004) Radiation burns as a severe complication of fluoroscopically-guided cardiological interventions. 4. Bernardi G, Padovani R, Morocutti G, Vano E, et al (2000). Clinical and technical determinants of the complexity of Percutaneous Transluminal Coronary Angioplasty: Analysis in relation to radiation exposure. Catheterization and Cardiovascular Interventions; 51, 1-9. 5. Padovani R, Bernardi G, Malison M R, Vano E, Morocutti G, Fioretti PM. (2001) Patient dose related to the complexity of interventional cardiology procedures. Radiation Protection Dosimetry. Vol. 94, No.1-2, pp 189-192 6. Neoffotistou V, Vano E, Padovani R, Kotre J, Dowling A, Toivonen M, Kottou S, Tsapaki V, Willis S, Bernardi G, Faulkner K. (2003). DIMOND EU PROJECT. Preliminary reference levels in interventional cardiology. Eur Radiol. 2003 Oct;13(10): pp 2259-63. 7. Hart D, Hillier M C, Wall B F (2000) NRPB- W 14. Doses to patients from medical x-ray examinations in the UK - 2000 review 3rd Quartile Values CA PCI PPI DAP (cGycm²) NPDD DIMOND This study 3,630 5,700 4,654 6,340 9,400 10,650 2,650 - 1,686 Time (min) 5.6 6 5 14.6 16 18 10.7 7.7