32A-2 Sample Injection system

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

Gas Chromatography 427 PHC.
GAS CHROMATOGRAPHY ENVE 202 Dr. Aslıhan Kerç.
GAS CHROMATOGRAPHY.
Lab Methods Day June 25, 2014 Gas Chromatography
The Foundations: Classical Split and Splitless Injection
Mobile phase is a gas! Stationary phase could be anything but a gas
1 HPLC Lecture Mobile Phase Selection in Partition Chromatography Optimization of the mobile phase composition and polarity is vital for obtaining.
Experiment 6 Simple and Fractional Distillation.
4. Advances in Gas Chromatography. Topics covered capillary columns headspace analysis solid phase micro-extraction.
Chapter 32 HIGH-PERRORMANCE LIQUID CHROMATOGRAPHY High-performance liquid chromatography (HPLC) is the most versatile and widely used type of elution chromatography.
Gas Chromatography.
Chapter 27 Gas Chromatography
Monitoring the desorption of analytes from nonpolar SPME fibers using high speed gas chromatography Authors: Kimberly Jasch, Tony Borgerding* Department.
Intro to Chromatographic Separations Chap 26. Originally based on separation and identification by color Originally based on separation and identification.
Gas Chromatography. Mobile phase: Inert gas such as N2 or He. Mobile phase: Inert gas such as N2 or He. Stationary phase: May be solid (GSC) or Stationary.
Gas Liquid Chromatography
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
GAS – LIQUID CHROMATOGRAPHY BY M. GLORY HEPSIBAH M.PHARM (PH. ANALYSIS) BHARAT COLLEGE OF PHARMACY.
Chapter 27 Gas Chromatography 1. Principles
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
SUPER CRITICAL FLUID CHROMATOGRAPHY
CHROMATOGRAPHY. The general name given to methods by which two or more compounds in a mixture are physically separated by distributing themselves between.
Gas Chromatography A separation science.... What is Chromatography? The separation of a mixture of two or more compounds or ions by distribution between.
High Performance Liquid Chromatography Instrumentation.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 12 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
INTRODUCTION TO CHROMATOGRAPY
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens K.G. Furton, J.R. Almirall,
Gas Chromatography Lecture 38.
Gas Chromatography Experiment. Gas Chromatography - Gas Chromatography (GC) is a common technique used to separate and identify volatile organic compounds.
By: Arafath and Nick. What is it  Chromatography is a technique that is used to separate the substances present in a mixture.  It is widely used to.
Analytical Separations
Basic Gas Chromatography. History Separation of dyes by Runge Separation of plant pigments by Tswett Theoretical gc (Martin & Synge)
1 Gas Chromatography Lecture Liquid Stationary Phases In general, the polarity of the stationary phase should match that of the sample constituents.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chapter 28 High Performance Liquid Chromatography.
Chapter 32 Gas Chromatography. In gas chromatography, the components of a vaporized sample are separated by being distributed between a mobile gaseous.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Gas Chromatography. In Gas Chromatography (GC), a gaseous mobile phase transports a gaseous solute through a long, thin column containing solid or liquid.
Lecture 9 Gas Chromatography Lecture 9 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Experiments in Analytical Chemistry
Reading assignment: section 26E(p781) Chapter 26 # 2, 3, 14, 15, 16 Chapter 27 # 7(a,d,f), 22, 23, 24, 25.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Chem. 133 – 5/9 Lecture.
6850/6890 分流动画 Split/Splitless 进样口 – 部件
Organic Chemistry Lab 315 Fall, 2016.
GAS CHROMATOGRAPH. GAS CHROMATOGRAPH Principle: Which type of compounds can analyse? Volatile Thermostable.
Chem. 133 – 5/11 Lecture.
An Introduction to Chromatographic Separations
An analytical instrumentation process
Chapter 27 Gas Chromatography
Supercritical Fluid Chromatography and Extraction
An Introduction to Chromatographic Separations
An Introduction to Chromatographic Separations
VAPOUR PHASE CHROMATOGRAPHY
Chromatography Daheeya Alenazi.
Principle of separation of different components:
High-Performance Liquid Chromatography
The retention factor, kA, for solute A is related to the rate at which A migrates through a column. It is the amount of time a solute spends in.
High-Performance Liquid Chromatography
5 week plan Each week you will have 2 single lessons and 1 double lesson. In those lessons you will learn aspects from Modern Analytical Techniques (MAT)
33A-2 Pumping Systems The requirements for liquid chromatographic pumps include the generation of pressures of up to 6000 psi (lb/in2), (2) pulse-free.
GAS CHROMATOGRAPHY.
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High performance liquid chromatography (HPLC)
Chromatography is a technique in which the components of a mixture are separated based on The differences in rates at which they are carried through a.
High-Performance Liquid Chromatography
Presentation transcript:

32A-2 Sample Injection system For high column efficiency, a suitably sized sample should be introduced as a “plug” of vapor. Slow injection or oversized samples cause band spreading and poor resolution. Calibrated microsyringes, such as those shown in Fig. 32-3, are used to inject liquid samples through a rubber or silicone diaphragm, or septum, into a heated sample port located at head of the column.

Figure 32-3 A set of microsyringes for sample injection.

The sample port (Fig. 32-4) is usually kept at about 50oC greater than the boiling point of the least volatile component of the sample. For ordinary packed analytical columns, sample sizes range from a few tenths of a microliter to 20 mL. Capillary columns require samples that are smaller by a factor of 100 or more. For these columns, a sample splitter is often needed to deliver a small known fraction (1:100 to 1:500) of the injected sample, with the remainder going to waste.

Figure 32-4 Cross-sectional view of a microflash vaporizer direct injector

Commercial gas chromatographs intended for use with capillary columns incorporate such splitters, and they also allow for splitless injection when packed columns are used.

For the most reproducible sample injection, newer gas chromatographs use autoinjectors and autosamplers, such as the system shown in Fig. 32-5. With such autoinjectors, syringes are filled, and the sample injected into the chromatograph automatically.

Figure 32-5 An autoinjection system with autosampler for gas chromatography.

In the autosampler, samples are contained in vials on a sample turntable. The autoinjector syringe picks up the sample through a septum on the vial and injects the sample through a septum on the chromatograph. With the unit shown, up to 150 sample vials can be placed on the turntable. Injection volumes can vary from 0.1 mL with a 10-mL syringe to 200 mL with a 200-ml syringe.

Standard deviations as low as 0 Standard deviations as low as 0.3% are common with autoinjection systems. For introducing gases, a sample valve, such as that shown in Fig. 32-6, is often used instead of a syringe. With such devices, sample sizes can be reproduced to better than 0.5% relative.

Figure 32-6 A rotary sample valve Figure 32-6 A rotary sample valve. Valve position (a) is for filling the sample loop ACB; position (b) is for introduction of sample into the column.

Liquid samples can also be introduced through a sampling valve. Solid samples are introduced as solutions or alternatively are sealed into thin-walled vials that can be inserted at the head of the column and punctured or crushed from the outside.

32A-3 Column Configurations and Column Ovens The columns in gas chromatography are of two general types: packed columns or capillary columns. In the past, the vast majority of gas chromatographic analyses used packed columns. For most current applications, packed columns have been replaced by more efficient and faster capillary columns.

Chromatographic columns vary in length from less than 2 m to 60 m or more. They are constructed of stainless steel, glass, fused silica, or Teflon. In order to fit into an oven for thermostating, they are usually formed as coils having diameters of 10 to 30 cm (Fig. 32-7).

Figure 32-7 Fused-silica capillary columns.

Column temperature is an important variable that must be controlled to a few tenths of a degree for precise work. Thus, the column is normally housed in a thermostated oven. The optimum column temperature depends on the boiling point of the sample and the degree of separation required. Roughly, temperature equal to or slightly above average boiling point of sample results in reasonable elution time (2 - 30 min).

For samples with a broad boiling range, it is often desirable to use temperature programming whereby the column temperature is increased either continuously or in steps as the separation proceeds. Fig. 32-8 shows the improvement in a chromatogram brought about by temperature programming. In general, optimum resolution is associated with minimal temperature.

Figure 32-8 Effect of temperature on gas chromatograms Figure 32-8 Effect of temperature on gas chromatograms. (a) Isothermal at 458C. (b) Isothermal at 1458C. (c) Programmed at 308 to 1808C

The cost of lowered temperature, however, is an increase in elution time and, therefore, the time required to complete an analysis (Fig. 32-8 a & b) Analytes of limited volatility can sometimes be determined by forming derivatives that are more volatile

Temperature programming in gas chromatography is achieved by increasing the column temperature continuously or in steps during elution.