TAL227 PARALLEL BEAM LOAD CELL

Slides:



Advertisements
Similar presentations
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
Advertisements

Analog-to-Digital Converter (ADC) And
Supercapacitor Energy Storage System for PV Power Generation
DIGITAL SCALE Taylor Model Components Control Board Back of LCD Display Load Cell under foot Battery Holder.
Load Cells Leann Armbrust Travis Wyatt SRJC, Engr 45 Fall 2010.
Product Line Overview Company Overview  Incorporated in 1983  Developed and patented first Electronic Cylinder Scale – Model.
Control System Instrumentation
Basic Measurement Concepts ISAT 253 Spring Dr. Ken Lewis Mod. 2 Measurement Concepts So far… In the Design of Experiments In the Design of Experiments.
“We Weigh The World!” CAS Newton-500 Series CAS Marketing Team CAS Corporation.
SENSORS AND TRANSDUCERS
The SEN kg Load Cell And The Wheatstone Bridge.
ECE 265 – LECTURE 16 Complete System Example A Weight Measurement System 8/13/ ECE265.
We are Group5 Weatherstation The team Members are : Saran Jackson Robert Howard Robert Garvey Gene Fitzgerald Steven Dowling.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Instrumentation and Measurements
Basics of Measurement and Instrumentation
Sensor (application to measurement)
Introduction  Exceptionally long life & high switching speeds.  Non contact, zero operation force.  Wear & maintenance free operation.  Bounce free.
All rights reserved. FUTEK 2006 SENSOR SOLUTION TIPS Presented by: Javad Mokhbery (President)
Smart transmitters.
Direct Current And Resistance Electric Current The Battery Resistance And Ohm’s Law Power Internal Resistance Resistors In Combination RC Circuits Written.
ENERGY INSTITUTE Battery Research Group NiMH Battery Pack for HEV Cem Kaypmaz 2008 İstanbul.
NAVIGATOR™ Portable Balances
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
Performance characteristics for measurement and instrumentation system
Part 1: Basic Principle of Measurements
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
Resistive Transducers Sensors Used in Electronics.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
E E 2315 Lecture 03 - Simple Resistive Circuits and Applications.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
Displacement and Motion Measurement
1 HD SIGNAL CONDITIONER SERIES LIMITER TRANSMITTER MODEL HD-LIM MODEL & SUFFIX CODE SELECTION HD-LIM MODEL ■ Output1 signal ■ Output2 signal Availability.
Chapter 2 Exercise Thermistor  Also called thermal resistor as the resistance varies as a function of temperature.  Manufactured in the form of beads,
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
E E 1205 Circuit Analysis Lecture 03 - Simple Resistive Circuits and Applications.
THE SUSTAINABLE COMPANY Development of entrepreneurship in vocational education Leonardo Project Second Meeting Tenerife – February 2013 Spanish team presentation.
Shree Swami Atmanand Saraswati Institute Of Technology Kathiriya Krishna Kheni Vaidehi Submitted to Prof.Pratik Desai Prof.Hetal.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Development of an AC Standard Shunt with Small Phase Angle and High Precision Copyright, 2002 © Japan Electric Meters Inspection Corporation JEMIC Takuhiro.
Done by: Khalid Hijjawi Mohammad Massad.  Is an electrical instrument that measures electrical resistance, the opposition to an electric current. The.
Displacement, Location or Position Sensor Muhajir Ab. Rahim School of Mechatronic Engineering, KUKUM.
EKT 451 CHAPTER 6 Sensor & Transducers.
Proximity Transducer System Operation
Smart, web enabled fridge Marty Lewis. Basic I/O INPUTS Weight/size Sensor Barcode Reader Touch Pad / Touchscreen LCD OUTPUTS SVGA LCD INPUT AND OUTPUT.
Resistance. Resistor A resistor is part of an electric circuit that resists the flow of electric current. As current flows through a resistor, some of.
Semiconductor Strain Gages
Signal Transmission and Conversion, Test Review - Agenda
(7) Measurement Systems.
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
II. Electric current 1. Definition a) Conventional current Electron
Intelligent controller with Microprocessor Incorporated NPS6220
RESISTANCE.
Newton-500 Series CAS Corporation CAS Marketing Team.
HD SIGNAL CONDITIONER SERIES
What exactly does each part of the circuit do?
Sensor presentation.
BCTW calibration status and future
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
Electronic Control Systems Week 4 – Signaling and Calibration
Pressure Level Sensor OTT PLS
MCP Electronics Time resolution, costs
استاد جناب آقای دکتر شمقدری
Customer Presentation
HD SIGNAL CONDITIONER SERIES
Lesson 10: Sensor and Transducer Electrical Characteristics
High Speed Turbojet Instrumentation
RESISTANCE.
SCM2100-V Series:Precision Vacuum Measurement
TOPIC- Load cell A load cell is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being.
Presentation transcript:

TAL227 PARALLEL BEAM LOAD CELL Features: ◆Capacity :5~50kg ◆Material: aluminum ◆Type: Parallel beam type ◆ Surface anodized and anti-corrosion ◆Defend grade: IP65 ◆Application: Electronic top scale, floor scale, balance and industrial weighing system. WWW.HTC-SENSOR.COM Electrical connection and Dimensions:(dimension unit: mm) Specifications: capacity kg 5, 8, 10, 15, 20, 30, 35,50 safe overload %FS 120 ultimate overload 150 rated output mV/V 2.0 ± 0.1 excitation voltage Vdc 9~ 12 combined error ± 0.02 zero balance ± 1.0 non-linearity hysteresis repeatability creep %FS/30min input resistance Ω 405 ± 10 output resistance 350 ± 3 insulation resistance M Ω ≥ 5000 @ 100 Vdc operating temperature range ℃ -20 ~ +60 compensated temperature range -10 ~ +40 temperature coefficient of SPAN %FS/10℃ temperature coefficient of ZERO ± 0.03 Electrical connection cable 4 core shielded PVC cable, Ø4.5 × 420 mm excitation(+):Red excitation(-):Black signal(+):Green signal(-):White ※Ordering code: model-capacity- rated output-accuracy-defend grade- the length of cable